Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography

被引:14
|
作者
Follet, H.
Peyrin, F.
Vidal-Salle, E.
Bonnassie, A.
Rumelhart, C.
Meunier, P. J.
机构
[1] INSA, CNRS, UMR 5514, LaMCoS, Lyon, France
[2] INSA, CNRS, UMR 5515, CREATIS, Lyon, France
[3] INSERM, U403, Lab Histodynam Osseuse, F-69008 Lyon, France
关键词
microcomputed tomography (mu CT); finite-element models; biomechanical strength; trabecular bone; calcaneus;
D O I
10.1016/j.jbiomech.2006.10.032
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To determine intrinsic mechanical properties (elastic and failure) of trabecular calcaneus bone, chosen as a good predictor of hip fracture, we looked for the influence of image's size on a numerical simulation. One cubic sample of cancellous bone (9 x 9 x 9 mm(3)) was removed from the body of the calcaneus (6 females, 6 males, 79 +/- 9yr). These samples were tested under compressive loading. Before compressive testing, these samples were imaged at 10.13 mu m resolution using a 3D microcomputed tomography (mu CT) (ESRF, France). The mu CT images were converted to finite-element models. Depending on the bone density values (BV/TV), we compared two different finite element models: a linear hexahedral and a linear beam finite element models. Apparent experimental Young's modulus (E-app(exp)) and maximum apparent experimental compressive stress (sigma(exp)(max)) were significantly correlated with bone density obtained by Archimedes's test (E-app(exp) = 236 +/- 231 MPa [19-742 MPa], sigma(exp)(max) = 2.61 +/- 1.97 MPa [0.28-5.81 MPa], r > 0.80, p < 0.001). Under threshold at 40 pm, the size of the numerical samples (5.18 3 and 6.6 83 MM3) seems to be an important parameter on the accuracy of the results. The numerical trabecular Young's modulus was widely higher (E-trabecular(num) = 34,182 +/- 22,830 MPa [9700-87,211 MPa]) for the larger numerical samples and high BV/TV than those found classically by other techniques (4700-15,000 MPa). For rod-like bone samples (BV/TV < 12%, n = 7), Young's modulus, using linear beam element (E-trabecular(num-skeleton): 10,305 +/- 5500 Mpa) were closer to the youns's modulus found by other techniques. Those results show the limitation of hexahedral finite elements at 40 mu n, mostly used, for thin trabecular structures. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2174 / 2183
页数:10
相关论文
共 50 条
  • [31] PRECONDITIONED FINITE-ELEMENT ALGORITHMS FOR 3D STOKES FLOWS
    ZHOU, RQN
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 1993, 17 (08) : 667 - 685
  • [32] A MIXED 3D FINITE-ELEMENT FOR MODELING THICK PLATES
    ASCH, M
    BERCOVIER, M
    COMPUTATIONAL MECHANICS, 1994, 13 (05) : 332 - 342
  • [33] A METHOD FOR THE IMPROVEMENT OF 3D SOLID FINITE-ELEMENT MESHES
    AMEZUA, E
    HORMAZA, MV
    HERNANDEZ, A
    AJURIA, MBG
    ADVANCES IN ENGINEERING SOFTWARE, 1995, 22 (01) : 45 - 53
  • [34] VOLUME VISUALIZATION OF 3D FINITE-ELEMENT METHOD RESULTS
    KOYAMADA, K
    NISHIO, T
    IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1991, 35 (1-2) : 12 - 25
  • [35] FINITE-ELEMENT SCHEME FOR TRANSIENT 3D EDDY CURRENTS
    LEONARD, PJ
    RODGER, D
    IEEE TRANSACTIONS ON MAGNETICS, 1988, 24 (01) : 90 - 93
  • [36] DIFFERENT FINITE-ELEMENT FORMULATIONS OF 3D MAGNETOSTATIC FIELDS
    PREIS, K
    BARDI, I
    BIRO, O
    MAGELE, C
    VRISK, G
    RICHTER, KR
    IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (02) : 1056 - 1059
  • [37] Feasibility of micro-crack detection in human trabecular bone images from 3D synchrotron microtomography
    Larrue, Ayrneric
    Rattner, Aline
    Laroche, Norbert
    Vico, Laurence
    Peyrin, Francoise
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3918 - 3921
  • [38] 3D analysis of microvasculature in murine liver fibrosis models using synchrotron radiation-based microtomography
    Willi L. Wagner
    Sonja Föhst
    Jessica Hock
    Yong Ook Kim
    Yury Popov
    Detlef Schuppan
    Katja Schladitz
    Claudia Redenbach
    Maximilian Ackermann
    Angiogenesis, 2021, 24 : 57 - 65
  • [39] Regional vascular mechanical properties by 3-D intravascular ultrasound with finite-element analysis
    Vonesh, MJ
    Cho, CH
    Pinto, JV
    Kane, BJ
    Lee, DS
    Roth, SI
    Chandran, KB
    McPherson, DD
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (01): : H425 - H437
  • [40] Allowing for arbitrary material models in a 3D finite-element method for magnetic field analysis
    Webb, JP
    Forghani, B
    NON-LINEAR ELECTROMAGNETIC SYSTEMS - ISEM '99, 2000, : 405 - 408