Comparison of HR-pQCT- and microCT-based finite element models for the estimation of the mechanical properties of the calcaneus trabecular bone

被引:10
|
作者
Alsayednoor, J. [1 ]
Metcalf, L. [2 ]
Rochester, J. [3 ]
Dall'Ara, E. [4 ,5 ]
McCloskey, E. [2 ,4 ,5 ]
Lacroix, D. [1 ]
机构
[1] Univ Sheffield, Dept Mech Engn, INSIGNEO Inst Sil Med, Mappin St, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Sheffield, Dept Oncol & Metab, MRC Arthrit UK Ctr Integrated Res Musculoskeletal, Sheffield, S Yorkshire, England
[3] Univ Sheffield, Med Sch, Acad Unit Med Educ, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Dept Oncol & Metab, Sheffield, S Yorkshire, England
[5] Univ Sheffield, INSIGNEO Inst Sil Med, Sheffield, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
In vivo assessment; Trabecular microstructure; Finite element model; HR-pQCT; Trabecular segmentation; Calcaneus; QUANTITATIVE COMPUTED-TOMOGRAPHY; DISTAL RADIUS; TOPOLOGICAL ANALYSIS; ELASTIC-MODULUS; MICROARCHITECTURE; PLATES; STRENGTH; IMAGES; RODS; CLASSIFICATION;
D O I
10.1007/s10237-018-1051-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The calcaneus bone is formed of extensive trabecular bone and is therefore well suited to be used as an example of loaded bone to establish the ability of combining microfinite element (microFE) technique with high-resolution peripheral quantitative computed tomography (HR-pQCT) in determining its mechanical properties. HR-pQCT is increasingly used as a tool for in vivo bone clinical research, but its use has been limited to the distal radius and tibia. The goal of this study was to determine the applicability of HR-pQCT-derived microFE models of the calcaneus trabecular bone with 82m voxel size with reference to higher-resolution microCT-based models taken as gold standard. By comparing the outputs of microFE models generated from both HR-pQCT and microCT images of the trabecular bone of five calcaneus cadaveric specimens, it was found that the HR-pQCT-based models predicted mechanical properties for fracture load, total reaction force and von Mises stress are considerably different from microCT-based counterparts by 33, 64 and 70%, respectively. Also, the morphological analysis showed a comprehensive geometrical difference between HR-pQCT-based microFE models and their microCT-based equivalents. The results of the HR-pQCT-based models were found to have strong dependency on the threshold value chosen to binarise the images prior to finite element modelling. In addition, it was found that the voxel size has a strong impact on accuracy of imaged-based microFE models compared to other factors such as the presence of soft tissue and image scanning integration time. Therefore, although HR-pQCT has shown to be useful to predict overall structural and biomechanical changes, it is limited in providing local accurate biomechanical properties of trabecular bone and therefore should be used with caution when assessing bone remodelling through local changes of trabecular bone apposition and resorption in disease treatment monitoring.
引用
收藏
页码:1715 / 1730
页数:16
相关论文
共 50 条
  • [1] Comparison of HR-pQCT- and microCT-based finite element models for the estimation of the mechanical properties of the calcaneus trabecular bone
    J. Alsayednoor
    L. Metcalf
    J. Rochester
    E. Dall’Ara
    E. McCloskey
    D. Lacroix
    Biomechanics and Modeling in Mechanobiology, 2018, 17 : 1715 - 1730
  • [2] Proximal Tibia Bone Stiffness and Strength in HR-pQCT- and QCT-Based Finite Element Models
    Nikolas K. Knowles
    Danielle E. Whittier
    Bryce A. Besler
    Steven K. Boyd
    Annals of Biomedical Engineering, 2021, 49 : 2389 - 2398
  • [3] Proximal Tibia Bone Stiffness and Strength in HR-pQCT- and QCT-Based Finite Element Models
    Knowles, Nikolas K.
    Whittier, Danielle E.
    Besler, Bryce A.
    Boyd, Steven K.
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (09) : 2389 - 2398
  • [4] MicroCT-based finite element models as a tool for virtual testing of cortical bone
    Ramezanzadehkoldeh, Masoud
    Skallerud, Bjorn H.
    MEDICAL ENGINEERING & PHYSICS, 2017, 46 : 12 - 20
  • [5] Intravoxel bone micromechanics for microCT-based finite element simulations
    Blanchard, Romane
    Dejaco, Alexander
    Bongaers, Evi
    Hellmich, Christian
    JOURNAL OF BIOMECHANICS, 2013, 46 (15) : 2710 - 2721
  • [6] Comparison of different microCT-based morphology assessment tools using human trabecular bone
    Steiner, Lukas
    Synek, Alexander
    Pahr, Dieter H.
    BONE REPORTS, 2020, 12
  • [7] Influence of mesh size and element type on apparent yield properties of microCT based finite element models of human trabecular bone
    Gross, T.
    Pahr, D. H.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING IV, 2014, : 415 - 418
  • [8] Precision of Bone Strength Estimation using HR-pQCT-Based Homogenized Finite Element Analysis
    Schenk, Denis
    Mathis, Andrea
    Zysset, Philippe
    Lippuner, Kurt
    JOURNAL OF BONE AND MINERAL RESEARCH, 2019, 34 : 192 - 192
  • [9] Prediction of mechanical properties of vertebral trabecular bone using microstructural finite element models
    Dai, Yifei
    Ryan, Jordan
    Niebur, Glen L.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 869 - 870
  • [10] Relationships Between the Stiffness of Peripheral and Central Skeletal Sites Assessed by HR-pQCT- and cQCT-Based Finite Element Analysis
    Yin, P. T.
    Liu, X. S.
    Cohen, A.
    Shane, E.
    Lappe, J. M.
    Recker, R. R.
    Guo, X. E.
    2010 IEEE 36TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2010,