Comparison of HR-pQCT- and microCT-based finite element models for the estimation of the mechanical properties of the calcaneus trabecular bone

被引:10
|
作者
Alsayednoor, J. [1 ]
Metcalf, L. [2 ]
Rochester, J. [3 ]
Dall'Ara, E. [4 ,5 ]
McCloskey, E. [2 ,4 ,5 ]
Lacroix, D. [1 ]
机构
[1] Univ Sheffield, Dept Mech Engn, INSIGNEO Inst Sil Med, Mappin St, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Sheffield, Dept Oncol & Metab, MRC Arthrit UK Ctr Integrated Res Musculoskeletal, Sheffield, S Yorkshire, England
[3] Univ Sheffield, Med Sch, Acad Unit Med Educ, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Dept Oncol & Metab, Sheffield, S Yorkshire, England
[5] Univ Sheffield, INSIGNEO Inst Sil Med, Sheffield, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
In vivo assessment; Trabecular microstructure; Finite element model; HR-pQCT; Trabecular segmentation; Calcaneus; QUANTITATIVE COMPUTED-TOMOGRAPHY; DISTAL RADIUS; TOPOLOGICAL ANALYSIS; ELASTIC-MODULUS; MICROARCHITECTURE; PLATES; STRENGTH; IMAGES; RODS; CLASSIFICATION;
D O I
10.1007/s10237-018-1051-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The calcaneus bone is formed of extensive trabecular bone and is therefore well suited to be used as an example of loaded bone to establish the ability of combining microfinite element (microFE) technique with high-resolution peripheral quantitative computed tomography (HR-pQCT) in determining its mechanical properties. HR-pQCT is increasingly used as a tool for in vivo bone clinical research, but its use has been limited to the distal radius and tibia. The goal of this study was to determine the applicability of HR-pQCT-derived microFE models of the calcaneus trabecular bone with 82m voxel size with reference to higher-resolution microCT-based models taken as gold standard. By comparing the outputs of microFE models generated from both HR-pQCT and microCT images of the trabecular bone of five calcaneus cadaveric specimens, it was found that the HR-pQCT-based models predicted mechanical properties for fracture load, total reaction force and von Mises stress are considerably different from microCT-based counterparts by 33, 64 and 70%, respectively. Also, the morphological analysis showed a comprehensive geometrical difference between HR-pQCT-based microFE models and their microCT-based equivalents. The results of the HR-pQCT-based models were found to have strong dependency on the threshold value chosen to binarise the images prior to finite element modelling. In addition, it was found that the voxel size has a strong impact on accuracy of imaged-based microFE models compared to other factors such as the presence of soft tissue and image scanning integration time. Therefore, although HR-pQCT has shown to be useful to predict overall structural and biomechanical changes, it is limited in providing local accurate biomechanical properties of trabecular bone and therefore should be used with caution when assessing bone remodelling through local changes of trabecular bone apposition and resorption in disease treatment monitoring.
引用
收藏
页码:1715 / 1730
页数:16
相关论文
共 50 条
  • [31] Women with previous fragility fractures can be classified based on bone microarchitecture and finite element analysis measured with HR-pQCT
    K. K. Nishiyama
    H. M. Macdonald
    D. A. Hanley
    S. K. Boyd
    Osteoporosis International, 2013, 24 : 1733 - 1740
  • [32] Finite element analysis of trabecular bone structure:: a comparison of image-based meshing techniques
    Ulrich, D
    van Rietbergen, B
    Weinans, H
    Rüegsegger, P
    JOURNAL OF BIOMECHANICS, 1998, 31 (12) : 1187 - 1192
  • [33] Validation of an HR-pQCT-based homogenized finite element approach using mechanical testing of ultra-distal radius sections
    Peter Varga
    Enrico Dall’Ara
    Dieter H. Pahr
    Michael Pretterklieber
    Philippe K. Zysset
    Biomechanics and Modeling in Mechanobiology, 2011, 10 : 431 - 444
  • [34] Grayscale MR Image Based Finite Element Mechanical Modeling of Trabecular Bone at In Vivo Resolution.
    Magland, J. F.
    Rajapakse, C. S.
    Wald, M. J.
    Vasilie, B.
    Guo, X. E.
    Zhang, X. H.
    Wehrli, F. W.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 : S310 - S310
  • [35] Validation of an HR-pQCT-based homogenized finite element approach using mechanical testing of ultra-distal radius sections
    Varga, Peter
    Dall'Ara, Enrico
    Pahr, Dieter H.
    Pretterklieber, Michael
    Zysset, Philippe K.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2011, 10 (04) : 431 - 444
  • [36] Estimation of the effective yield properties of human trabecular bone using nonlinear micro-finite element analyses
    Patrik Wili
    Ghislain Maquer
    Jarunan Panyasantisuk
    Philippe K. Zysset
    Biomechanics and Modeling in Mechanobiology, 2017, 16 : 1925 - 1936
  • [37] Osteoporosis imaging: effects of bone preservation on MDCT-based trabecular bone microstructure parameters and finite element models
    Baum, Thomas
    Garcia, Eduardo Grande
    Burgkart, Rainer
    Gordijenko, Olga
    Liebl, Hans
    Jungmann, Pia M.
    Gruber, Michael
    Zahel, Tina
    Rummeny, Ernst J.
    Waldt, Simone
    Bauer, Jan S.
    BMC MEDICAL IMAGING, 2015, 15
  • [38] Osteoporosis imaging: effects of bone preservation on MDCT-based trabecular bone microstructure parameters and finite element models
    Thomas Baum
    Eduardo Grande Garcia
    Rainer Burgkart
    Olga Gordijenko
    Hans Liebl
    Pia M. Jungmann
    Michael Gruber
    Tina Zahel
    Ernst J. Rummeny
    Simone Waldt
    Jan S. Bauer
    BMC Medical Imaging, 15
  • [39] Estimation of the effective yield properties of human trabecular bone using nonlinear micro-finite element analyses
    Wili, Patrik
    Maquer, Ghislain
    Panyasantisuk, Jarunan
    Zysset, Philippe K.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2017, 16 (06) : 1925 - 1936
  • [40] A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models
    Biomechanics Section, Institute of Orthopaedics, University of Nijmegen, Netherlands
    不详
    不详
    J. BIOMECH., 1 (69-81):