Effects of plastic film in a loosed powder form of sample preparation on elemental analysis by portable X-ray fluorescence spectrometer

被引:2
|
作者
Nuchdang, S. [1 ]
Patthaveekongka, W. [2 ]
Rattanaphra, D. [1 ]
机构
[1] Thailand Inst Nucl Technol, Publ Org, Res & Dev Div, Nakhon Nayok 26120, Thailand
[2] Silpakorn Univ, Dept Chem Engn, Fac Engn & Ind Technol, Nakhon Pathom 7300, Thailand
关键词
TRACE-ELEMENTS; XRF ANALYSIS;
D O I
10.1088/1755-1315/398/1/012004
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this research was to study the effects of plastic film types and film thickness on elemental analysis by portable X-ray fluorescence spectrometer (pXRF). Mylar polyester film with 3.6 mu m and 6.0 mu m thickness, and 4.0 mu m Prolene thin film were used in this study. Five rock samples were prepared by loosed powder method. The pXRF analysis of each plastic films was calibrated and evaluated the method with seven reference materials. The calibrated curves of three films were strongly correlated to referenced values (R-2 > 0.95) for Al, Ca, Fe, K, Mn, Si, Sr, Th, Ti, V, Y, Zn and Zr, except for Cu, Nb, Ni, P, U, V and W. The results showed that the pXRF could be used to determine some elements in rock samples and the thickness and types of the analyzed film influenced on the analysis. The element determination using each film required the developed method by calibration curve construction (linear regression of measured values obtained by the pXRF instrument against their certified values). In addition, the results after the recalibration of each film (both Prolene thin film and Mylar polyester film) agreed well.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Trace Elemental Determination Using a Portable Total Reflection X-Ray Fluorescence Spectrometer with a Collodion Film Sample Holder
    Shinsuke Kunimura
    Tomoki Shinkai
    [J]. Analytical Sciences, 2017, 33 : 635 - 637
  • [2] Trace Elemental Determination Using a Portable Total Reflection X-Ray Fluorescence Spectrometer with a Collodion Film Sample Holder
    Kunimura, Shinsuke
    Shinkai, Tomoki
    [J]. ANALYTICAL SCIENCES, 2017, 33 (05) : 635 - 638
  • [3] Portable Total Reflection X-ray Fluorescence Spectrometer with a Collodion Film Sample Holder
    Kunimura, Shinsuke
    Nakano, Kazuhiro
    Shinkai, Tomoki
    [J]. ISIJ INTERNATIONAL, 2015, 55 (08) : 1794 - 1796
  • [4] Elemental assessment of vegetation via portable X-ray fluorescence: Sample preparation and methodological considerations
    Zhou, Shubin
    Weindorf, David C.
    Cheng, Qiuming
    Yang, Biying
    Yuan, Zhaoxian
    Chakraborty, Somsubhra
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 174
  • [5] The use of a portable X-ray fluorescence spectrometer for measuring nickel in plants: sample preparation and validation
    Lima, Luiz Henrique Vieira
    da Silva, Fernando Bruno Vieira
    Echevarria, Guillaume
    do Nascimento, Clistenes Williams Araujo
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2024, 196 (06)
  • [6] Application of a Portable Total Reflection X-Ray Fluorescence Spectrometer to a Trace Elemental Analysis of Wines
    Kunimura, Shinsuke
    Kawai, Jun
    [J]. BUNSEKI KAGAKU, 2009, 58 (12) : 1041 - 1045
  • [7] Portable x-ray fluorescence spectrometer with a pyroelectric x-ray generator
    Ida, H
    Kawai, J
    [J]. X-RAY SPECTROMETRY, 2005, 34 (03) : 225 - 229
  • [8] Trace elemental determination by portable total reflection X-ray fluorescence spectrometer with low wattage X-ray tube
    Kunimura, Shinsuke
    Kawai, Jun
    [J]. X-RAY SPECTROMETRY, 2013, 42 (03) : 171 - 173
  • [9] Analysis of art objects using a portable x-ray fluorescence spectrometer
    Moioli, P
    Seccaroni, C
    [J]. X-RAY SPECTROMETRY, 2000, 29 (01) : 48 - 52
  • [10] Trace Elemental Analysis of Commercial Bottled Drinking Water by a Portable Total Reflection X-ray Fluorescence Spectrometer
    Shinsuke Kunimura
    Jun Kawai
    [J]. Analytical Sciences, 2007, 23 : 1185 - 1188