A Quantitative Description of the Percentage of Breast Density Measurement Using Full-field Digital Mammography

被引:33
|
作者
Heine, John J. [1 ]
Cao, Ke [1 ]
Rollison, Dana E. [1 ]
Tiffenberg, Gail [1 ]
Thomas, Jerry A. [2 ]
机构
[1] Univ S Florida, Coll Med, H Lee Moffitt Canc Ctr & Res Inst, Div Canc Prevent & Control, Tampa, FL 33612 USA
[2] Via Christi Reg Med Ctr, Wichita, KS USA
关键词
Breast density; calibration; breast cancer risk; full-field digital mammography; X-RAY ABSORPTIOMETRY; CANCER RISK; FORM; CALIBRATION;
D O I
10.1016/j.acra.2010.12.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Breast density is a significant breast cancer risk factor that is measured from mammograms. However, uncertainty remains in both understanding its underlying physical properties as it relates to the breast and determining the optimal method for its measurement. A quantitative description of the information captured by the standard operator-assisted percentage of breast density (PD) measure was developed using full-field digital mammography (FFDM) images that were calibrated to adjust for interimage acquisition technique differences. Materials and Methods: The information captured by the standard PD measure was quantified by developing a similar measure of breast density (PDc) from calibrated mammograms automatically by applying a static threshold to each image. The specific threshold was estimated by first sampling the probability distributions for breast tissue in calibrated mammograms. A percent glandular (PG) measure of breast density was also derived from calibrated mammograms. The PD, PDc, and PG breast density measures were compared using both linear correlation (R) and quartile odds ratio measures derived from a matched case-control study. Results: The standard PD measure is an estimate of the number of pixel values above a fixed idealized x-ray attenuation fraction. There was significant correlation (P<.0001) between the PDc-PD (r = 0.78), PDc-PG (r = 0.87), and PD-PG (r = 0.71) measures of breast density. Risk estimates associated with the lowest to highest quartiles for the PDc measure (odds ratio [OR]: 1.0 ref., 3.4, 3.6, and 5.6), and the standard PD measure (OR 1.0 ref., 2.9, 4.8, and 5.1) were similar and greater than that of the calibrated PG measure (OR 1.0 ref., 2.0, 2.4, and 2.4). Conclusions: The information captured by the standard PD measure was quantified as it relates to calibrated mammograms and used to develop an automated method for measuring breast density. These findings represent an initial step for developing an automated measure built on an established calibration platform. A fully developed automated measure may be useful for both research- and clinical-based risk applications.
引用
收藏
页码:556 / 564
页数:9
相关论文
共 50 条
  • [1] Automated Percentage of Breast Density Measurements for Full-field Digital Mammography Applications
    Fowler, Erin E. E.
    Vachon, Celine M.
    Scott, Christopher G.
    Sellers, Thomas A.
    Heine, John J.
    [J]. ACADEMIC RADIOLOGY, 2014, 21 (08) : 958 - 970
  • [2] Automatic evaluation of breast density for full-field digital mammography
    Lou, SL
    Fan, Y
    [J]. MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 1362 - 1369
  • [3] Volumetric breast density estimation method for full-field digital mammography
    Yang, J
    Rico, D
    Mawdsley, GE
    Yaffe, M
    [J]. RADIOLOGY, 2001, 221 : 192 - 192
  • [4] Performance of full-field digital mammography versus digital breast
    Wang, Mengru
    Zhuang, Shan
    Sheng, Liuli
    Zhao, Yu Nian
    Shen, Wenrong
    [J]. PRECISION MEDICAL SCIENCES, 2022, 11 (02): : 56 - 61
  • [5] Full-field digital mammography
    Bick, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [6] Full-field digital mammography
    U Bick
    [J]. Breast Cancer Research, 2 (Suppl 2)
  • [7] Combinations of Digital Breast Tomosynthesis and Full-field Digital Mammography for Different Density Types of Breasts
    Chen, Qiong
    Pan, Xin
    Xu, Junfeng
    Ying, Weifeng
    Hou, Yuyu
    Lu, Ming
    An, Dongqin
    Peng, Weijun
    [J]. CURRENT MEDICAL IMAGING, 2024, 20
  • [8] Digital Mammography Versus Full-Field Digital Mammography
    Hall, Ferris M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : 240 - 240
  • [9] A Multisite Study of a Breast Density Deep Learning Model for Full-Field Digital Mammography and Synthetic Mammography
    Matthews, Thomas P.
    Singh, Sadanand
    Mombourquette, Brent
    Su, Jason
    Shah, Meet P.
    Pedemonte, Stefano
    Long, Aaron
    Maffit, David
    Gurney, Jenny
    Hoil, Rodrigo Morales
    Ghare, Nikita
    Smith, Douglas
    Moore, Stephen M.
    Marks, Susan C.
    Wahl, Richard L.
    [J]. RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2021, 3 (01)
  • [10] Impact of Breast Density on Computer-Aided Detection in Full-Field Digital Mammography
    Silvia Obenauer
    Christian Sohns
    Carola Werner
    Eckhardt Grabbe
    [J]. Journal of Digital Imaging, 2006, 19