A Quantitative Description of the Percentage of Breast Density Measurement Using Full-field Digital Mammography

被引:33
|
作者
Heine, John J. [1 ]
Cao, Ke [1 ]
Rollison, Dana E. [1 ]
Tiffenberg, Gail [1 ]
Thomas, Jerry A. [2 ]
机构
[1] Univ S Florida, Coll Med, H Lee Moffitt Canc Ctr & Res Inst, Div Canc Prevent & Control, Tampa, FL 33612 USA
[2] Via Christi Reg Med Ctr, Wichita, KS USA
关键词
Breast density; calibration; breast cancer risk; full-field digital mammography; X-RAY ABSORPTIOMETRY; CANCER RISK; FORM; CALIBRATION;
D O I
10.1016/j.acra.2010.12.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Breast density is a significant breast cancer risk factor that is measured from mammograms. However, uncertainty remains in both understanding its underlying physical properties as it relates to the breast and determining the optimal method for its measurement. A quantitative description of the information captured by the standard operator-assisted percentage of breast density (PD) measure was developed using full-field digital mammography (FFDM) images that were calibrated to adjust for interimage acquisition technique differences. Materials and Methods: The information captured by the standard PD measure was quantified by developing a similar measure of breast density (PDc) from calibrated mammograms automatically by applying a static threshold to each image. The specific threshold was estimated by first sampling the probability distributions for breast tissue in calibrated mammograms. A percent glandular (PG) measure of breast density was also derived from calibrated mammograms. The PD, PDc, and PG breast density measures were compared using both linear correlation (R) and quartile odds ratio measures derived from a matched case-control study. Results: The standard PD measure is an estimate of the number of pixel values above a fixed idealized x-ray attenuation fraction. There was significant correlation (P<.0001) between the PDc-PD (r = 0.78), PDc-PG (r = 0.87), and PD-PG (r = 0.71) measures of breast density. Risk estimates associated with the lowest to highest quartiles for the PDc measure (odds ratio [OR]: 1.0 ref., 3.4, 3.6, and 5.6), and the standard PD measure (OR 1.0 ref., 2.9, 4.8, and 5.1) were similar and greater than that of the calibrated PG measure (OR 1.0 ref., 2.0, 2.4, and 2.4). Conclusions: The information captured by the standard PD measure was quantified as it relates to calibrated mammograms and used to develop an automated method for measuring breast density. These findings represent an initial step for developing an automated measure built on an established calibration platform. A fully developed automated measure may be useful for both research- and clinical-based risk applications.
引用
收藏
页码:556 / 564
页数:9
相关论文
共 50 条
  • [31] Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
    Badano, Aldo
    Graff, Christian G.
    Badal, Andreu
    Sharma, Diksha
    Zeng, Rongping
    Samuelson, Frank W.
    Glick, Stephen J.
    Myers, Kyle J.
    [J]. JAMA NETWORK OPEN, 2018, 1 (07) : e185474
  • [32] Advantages of gridless full-field digital mammography
    Nykanen, KM
    Siltanen, S
    [J]. RADIOLOGY, 2002, 225 : 120 - 121
  • [33] Mammographic Artifacts on Full-Field Digital Mammography
    Choi, Jae Jeong
    Kim, Sung Hun
    Kang, Bong Joo
    Choi, Byung Gil
    Song, ByungJoo
    Jung, Haijo
    [J]. JOURNAL OF DIGITAL IMAGING, 2014, 27 (02) : 231 - 236
  • [34] Current status of full-field digital mammography
    Pisano, ED
    [J]. RADIOLOGY, 2000, 214 (01) : 26 - 28
  • [35] Mammographic Artifacts on Full-Field Digital Mammography
    Jae Jeong Choi
    Sung Hun Kim
    Bong Joo Kang
    Byung Gil Choi
    ByungJoo Song
    Haijo Jung
    [J]. Journal of Digital Imaging, 2014, 27 : 231 - 236
  • [36] Current status of full-field digital mammography
    Pisano, ED
    Yaffe, MJ
    Hemminger, BM
    Hendrick, RE
    Niklason, LT
    Maidment, ADA
    Kimme-Smith, CM
    Feig, SA
    Sickles, EA
    Braeuning, MP
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (04) : 266 - 280
  • [37] Advantages of gridless full-field digital mammography
    Nykänen, K
    Siltanen, S
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 137 - 146
  • [38] Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls
    Salkowski, Lonie R.
    Elezaby, Mai
    Fowler, Amy M.
    Burnside, Elizabeth
    Woods, Ryan W.
    Strigel, Roberta M.
    [J]. 14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [39] Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls
    Salkowski, Lonie R.
    Elezaby, Mai
    Fowler, Amy M.
    Burnside, Elizabeth
    Woods, Ryan W.
    Strigel, Roberta M.
    [J]. JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [40] Clinical comparison of full-field digital mammography and screen-film mammography of breast cancer
    Lewin, JM
    D'Orsi, CJ
    Hendrick, RE
    Moss, LJ
    Isaacs, PK
    Karellas, A
    Cutter, GR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (03) : 671 - 677