Monte Carlo based verification of a beam model used in a treatment planning system

被引:2
|
作者
Wieslander, E. [1 ]
Knoos, T. [1 ]
机构
[1] Univ Lund Hosp, S-22185 Lund, Sweden
关键词
D O I
10.1088/1742-6596/102/1/012027
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Modern treatment planning systems (TPSs) usually separate the dose modelling into a beam modelling phase, describing the beam exiting the accelerator, followed by a subsequent dose calculation in the patient. The aim of this work is to use the Monte Carlo code system EGSnrc to study the modelling of head scatter as well as the transmission through multi-leaf collimator (MLC) and diaphragms in the beam model used in a commercial TPS (MasterPlan, Nucletron B. V.). An Elekta Precise linear accelerator equipped with an MLC has been modelled in BEAMnrc, based on available information from the vendor regarding the material and geometry of the treatment head. The collimation in the MLC direction consists of leafs which are complemented with a backup diaphragm. The characteristics of the electron beam, i. e., energy and spot size, impinging on the target have been tuned to match measured data. Phase spaces from simulations of the treatment head are used to extract the scatter from, e. g., the flattening filter and the collimating structures. Similar data for the source models used in the TPS are extracted from the treatment planning system, thus a comprehensive analysis is possible. Simulations in a water phantom, with DOSXYZnrc, are also used to study the modelling of the MLC and the diaphragms by the TPS. The results from this study will be helpful to understand the limitations of the model in the TPS and provide knowledge for further improvements of the TPS source modelling.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] A Monte Carlo approach to the validation of a pencil beam algorithm used in treatment planning for static conformal beam radiosurgery
    Belec, J
    Patrocinio, H
    Verhaegen, F
    MEDICAL PHYSICS, 2004, 31 (06) : 1714 - 1714
  • [32] Monte Carlo based treatment planning for modulated electron beam radiation therapy
    Lee, MC
    Deng, J
    Li, JS
    Jiang, SB
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08): : 2177 - 2199
  • [33] Verification of the monitor units calculations of the new commercial Monte Carlo based treatment planning system for electron beams
    Daskalov, G
    Cygler, J
    MEDICAL PHYSICS, 2003, 30 (07) : 1951 - 1952
  • [34] Convergent Pencil Beam Modeling with Monte Carlo Transport Codes for Synchrotron Based Intensity Modulated Proton Beam System Model in Eclipse Treatment Planning System
    Moskvin, V.
    Zhao, L.
    Farr, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E266 - E267
  • [35] Monte Carlo dose verification for MRI-based treatment planning of prostate cancer
    Chen, Z
    Yang, J
    Li, J
    Paskalev, K
    Ma, C
    Chen, L
    MEDICAL PHYSICS, 2005, 32 (06) : 2147 - 2147
  • [36] THE DOSIMETRIC VERIFICATION OF A PENCIL BEAM BASED TREATMENT PLANNING SYSTEM
    KNOOS, T
    CEBERG, C
    WEBER, L
    NILSSON, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10): : 1609 - 1628
  • [37] THE USED OF COMPUTED TOMOGRAPHY IMAGES FOR MONTE CARLO TREATMENT PLANNING
    Bazalova, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S50 - S50
  • [38] Commissioning of a photon beam model for Monte Carlo dose calculation in dynamic IMRT and comparison with a treatment planning system
    Hartmann, M
    Fippei, M
    Kunz, G
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S153 - S153
  • [39] A virtual-accelerator-based verification of a Monte Carlo dose calculation algorithm for electron beam treatment planning in homogeneous phantoms
    Wieslander, E
    Knöös, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : 1533 - 1544
  • [40] Acceptance and Commissioning of a Treatment Planning System Based on Monte Carlo Calculations
    Lopez-Tarjuelo, J.
    Garcia-Molla, R.
    Juan-Senabre, X. J.
    Quiros-Higueras, J. D.
    Santos-Serra, A.
    de Marco-Blancas, N.
    Calzada-Feliu, S.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (02) : 129 - 138