A virtual-accelerator-based verification of a Monte Carlo dose calculation algorithm for electron beam treatment planning in homogeneous phantoms

被引:3
|
作者
Wieslander, E [1 ]
Knöös, T [1 ]
机构
[1] Univ Lund Hosp, Dept Radiat Phys, SE-22185 Lund, Sweden
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 06期
关键词
Radiotherapy;
D O I
10.1088/0031-9155/51/6/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
By introducing Monte Carlo (MC) techniques to the verification procedure of dose calculation algorithms in treatment planning systems (TPSs), problems associated with conventional measurements can be avoided and properties that are considered unmeasurable can be studied. The aim of the study is to implement a virtual accelerator, based on MC simulations, to evaluate the performance of a dose calculation algorithm for electron beams in a commercial TPS. The TPS algorithm is MC based and the virtual accelerator is used to study the accuracy of the algorithm in water phantoms. The basic test of the implementation of the virtual accelerator is successful for 6 and 12 MeV (gamma < 1.0, 0.02 Gy/2 mm). For 18 MeV, there are problems in the profile data for some of the applicators, where the TPS underestimates the dose. For fields equipped with patient-specific inserts, the agreement is generally good. The exception is 6 MeV where there are slightly larger deviations. The concept of the virtual accelerator is shown to be feasible and has the potential to be a powerful tool for vendors and users.
引用
收藏
页码:1533 / 1544
页数:12
相关论文
共 50 条
  • [1] A virtual-acceterator-based verification of a Monte Carlo dose calculation algorithm for electron beam treatment planning in clinical situations
    Wieslander, Elinore
    Knoos, Tommy
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 82 (02) : 208 - 217
  • [2] A virtual electron accelerator, based on Monte Carlo, for verification of a commercial Monte Carlo electron treatment planning system
    Wieslander, E
    Traneus, E
    Knööds, T
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S375 - S375
  • [3] Evaluation of a Commercial Monte Carlo Dose Calculation Algorithm for Electron Beam Treatment Planning
    Chamberland, E.
    Lachance, B.
    Beaulieu, L.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [4] Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning
    Chamberland, Eve
    Beaulieu, Luc
    Lachance, Bernard
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 60 - 79
  • [5] Verification of a commercial implementation of the Macro-Monte-Carlo electron dose calculation algorithm using the virtual accelerator approach
    Tertel, Jakob
    Wulff, Joerg
    Karle, Heiko
    Zink, Klemens
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2010, 20 (01): : 51 - 60
  • [6] Evaluation of a Commercial Monte Carlo Dose Calculation Algorithm for Electron Treatment Planning
    Huang, J.
    Dunkerley, D.
    Smilowitz, J.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E546 - E546
  • [7] Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning
    Huang, Jessie Y.
    Dunkerley, David
    Smilowitz, Jennifer B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 184 - 193
  • [8] Experimental verification and clinical implementation of a commercial Monte Carlo electron beam dose calculation algorithm
    Fragosoa, Margarida
    Pillai, Sushakumari
    Solberg, Timothy D.
    Chetty, Indrin J.
    [J]. MEDICAL PHYSICS, 2008, 35 (03) : 1028 - 1038
  • [9] Verification of a proton treatment-planning pencil-beam dose algorithm with Monte Carlo
    Titt, U.
    Zheng, Y.
    Zhu, X.
    Mohan, R.
    Newhauser, W.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2149 - 2149
  • [10] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beam radiotherapy
    Hu, A.
    Song, H.
    Chen, Z.
    Zhou, S.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2099 - 2099