Source model tuning for a 6 MV photon beam used in radiotherapy

被引:0
|
作者
Hirschi, Lukas A. [1 ,2 ,3 ]
Siebers, Jeffrey V. [3 ]
Fix, Michael K. [1 ,2 ]
机构
[1] Inselspital Bern, Div Med Radiat Phys, Bern, Switzerland
[2] Univ Bern, CH-3012 Bern, Switzerland
[3] Virginia Commonwealth Univ, Richmond, VA USA
关键词
D O I
10.1088/1742-6596/74/1/012008
中图分类号
O59 [应用物理学];
学科分类号
摘要
The purpose of this work was to do a feasibility study on a procedure for tuning the mean energy T) and the spatial spread (sigma(R)) of the initial electron beam hitting the bremsstrahlung target as a part of a multicomponent source model, so that dose distributions predicted by Monte Carlo simulations (MC) will dosimetrically match measurements. The dose in a water phantom is considered to be a sum of doses produced by different components of a linear accelerator, namely target (TGT), flattening filter (1717), and primary collimator (PC). A histogram-based source model is used to model the phase space output of the 6 MV linear accelerator (VARIAN CL21EX). The phantom dose contribution from the target subsource has the greatest sensitivity to the initial beam parameters ((E) over bar sigma(R)), whereas the FF and PC subsource dose distributions axe only weakly dependent on them. In order to create a source model that could be tuned and used for a continuous range of (E) over bar and sigma(R), a method to interpolate across the histograms created with this data and to determine the sampling weights is developed, i.e. energy and radial-dependent interpolative polynomial fits to the histograms. The simulated dose distribution is then iteratively tuned to measured dose by changing the beam parameters, computing the corresponding dose distribution and compare simulation with measurements. This process is repeated until simulated dose matches measurements. The method ensures that the relative weights of radiation subsources are consistent with those that would be derived from full MC simulations of the treatment head. For comparison, the depth dose and the lateral dose profiles at various depths of the 10 x 10 cm(2) 20 x 20 cm(2), and 30 x 30 cm(2) field sizes are used. This study showed that a general source model tuning is feasible.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] A Simple Source Model for 6 MV Flattening Filter Free Photon Beams Monte Carlo Dose Calculations
    Ezzati, Ahad Ollah
    Studenski, Matthew T.
    Jamshidi, Negin
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2021, 18 (07) : 791 - 798
  • [42] A Simple Source Model for 6 MV Flattening Filter Free Photon Beams Monte Carlo Dose Calculations
    Matthew T. Ahad Ollah Ezzati
    Negin Studenski
    Physics of Particles and Nuclei Letters, 2021, 18 : 791 - 798
  • [43] Out-of-field beam characteristics of a 6 MV photon beam: Results of a Monte Carlo study
    Atarod, M.
    Shokrani, P.
    Azarnoosh, A.
    APPLIED RADIATION AND ISOTOPES, 2013, 72 : 182 - 194
  • [44] A Monte Carlo model of an agility head for a 10-MV photon beam
    Almatani, Turki
    Hugtenburg, Richard P.
    Smakovs, Artjoms
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2022, 16 (01): : 300 - 307
  • [45] Monte Carlo simulation of Varian Linac for 6 MV photon beam with BEAMnrc code
    Mohammed, Maged
    El Bardouni, T.
    Chakir, E.
    Boukhal, H.
    Saeed, M.
    Ahmed, Abdul-Aziz
    RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 69 - 75
  • [46] Dosimetric effect of jaws for small MLC fields in 6 and 15 MV photon beam
    Chow, J
    Seguin, M
    Alexander, A
    MEDICAL PHYSICS, 2005, 32 (06) : 1981 - 1982
  • [47] Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom
    Farajollahi A.
    Mesbahi A.
    Radiation Medicine, 2006, 24 (4): : 269 - 276
  • [48] 6 MV Photon Beam Induced UV/VIS Absorption of Hema Polymer Gel
    Ishak, Siti Atiqah
    Shahrim, Iskandar
    Siti, K. A. R.
    Alrahman, Azhar A.
    SAINS MALAYSIANA, 2017, 46 (02): : 303 - 308
  • [49] Monte Carlo study of the influence of a novel transmission detector on 6 MV photon beam
    Asuni, G.
    McCurdy, B.
    Jensen, M.
    MEDICAL PHYSICS, 2009, 36 (09) : 4309 - 4309
  • [50] Evaluation of the usefulness of a MOSFET detector in an anthropomorphic phantom for 6-MV photon beam
    Kohno R.
    Hirano E.
    Kitou S.
    Goka T.
    Matsubara K.
    Kameoka S.
    Matsuura T.
    Ariji T.
    Nishio T.
    Kawashima M.
    Ogino T.
    Radiological Physics and Technology, 2010, 3 (2) : 104 - 112