Monte Carlo simulation of Varian Linac for 6 MV photon beam with BEAMnrc code

被引:7
|
作者
Mohammed, Maged [1 ,2 ]
El Bardouni, T. [1 ]
Chakir, E. [2 ]
Boukhal, H. [1 ]
Saeed, M. [1 ]
Ahmed, Abdul-Aziz [1 ]
机构
[1] Univ Abdelmalek Essaadi, Fac Sci, Radiat & Nucl Syst Lab, Tetouan, Morocco
[2] Ibn Tofail Univ, Fac Sci, SIMO LAB, Kenitra, Morocco
关键词
EGSnrc; Photon cross section; Dose distribution; Monte Carlo; PARAMETERS;
D O I
10.1016/j.radphyschem.2017.11.017
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The purpose of this study is to investigate the effects of the initial electron beam parameters on the absorbed dose distribution calculated with EGSnrc Monte Carlo code, for 6 MV photon beam. A proposed methodology for benchmarking the BEAMnrc model of Varian Linac has been used. Also, a new photon cross section data based on ENDF/B-VII release 8 evaluation has been employed. The parameters tested include mean energy, radial intensity distribution and angular spread of the initial electron beam. Mean energy and angular spread were tested for a square irradiation field 10 x 10 cm(2), whereas beam width of the electron beam was studied for 10 x 10 cm(2) at different depths and 30 x 30 cm2 at depth of 10 cm. The results obtained are compared with measurement data to select the optimal electron beam parameters. The differences between MC calculation and measurements data are analyzed using gamma index criteria which fixed within 1% 1 mm accuracy. The obtained results indicated that the depth-dose and dose-profile curves were considerably influenced by the mean energy of the electron beam. The depth-dose curves were unaffected by the beam width of the electron beam, for both irradiation fields. On the contrary, lateral dose-profile curves were affected by the beam width of initial electron beam. Both dose-profile and depth-dose curves were unaffected to the angular spread of the electron beam. A deep depth of 10 x 10 cm(2) is very accurate to tune the beam width. Mean energy and beam width must be tuned precisely, to get the MC does distribution with acceptable accuracy.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [1] Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam
    Salama, E.
    Ali, A. S.
    Emad, N.
    Radi, A.
    [J]. ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (02): : 70 - 76
  • [2] Monte Carlo Simulation-Based BEAMnrc Code of a 6 MV Photon Beam Produced by a Linear Accelerator (LINAC)
    Sapundani, R.
    Ekawati, R.
    Wibowo, K. M.
    [J]. ATOM INDONESIA, 2021, 47 (03) : 199 - 204
  • [3] Validation of Monte Carlo simulation of 6 MV photon beam produced by Varian Clinac 2100 linear accelerator using BEAMnrc code and DOSXYZnrc code
    Bencheikh M.
    Maghnouj A.
    Tajmouati J.
    Didi A.
    Ezzati A.O.
    [J]. Physics of Particles and Nuclei Letters, 2017, 14 (5) : 780 - 787
  • [4] Validation of Monte carlo Geant4 multithreading code for a 6 MV photon beam of varian linac on the grid computing
    Assalmi, Mustapha
    Diaf, El Yamani
    Mansour, Najim
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (06) : 1001 - 1010
  • [5] Validation of Monte Carlo Geant4 code for a 6 MV Varian linac
    EL Bakkali, Jaafar
    EL Bardouni, Tarek
    [J]. JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2017, 29 (01) : 106 - 113
  • [6] Commissioning of a Varian Clinac iX 6 MV Photon Beam using Monte Carlo Simulation
    Dirgayussa, I. Gde Eka
    Yani, Sitti
    Rhani, M. Fahdillah
    Haryanto, Freddy
    [J]. 5TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND NATURAL SCIENCES (ICMNS 2014), 2015, 1677
  • [7] Validation of BEAMnrc Monte Carlo model for a 12 MV photon beam
    Mohammed, Maged
    El Bardouni, T.
    Chakir, E.
    Saeed, M.
    Jamal, Al Zain
    Mohamed, Landour
    [J]. JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2018, 30 (04) : 537 - 543
  • [8] Monte Carlo study of a flattening filter-free 6 MV photon beam using the BEAMnrc code.
    Kajaria, Ankit
    Sharma, Neeraj
    Sharma, Shiru
    Pradhan, Satyajit
    Mandal, Abhijit
    Aggarwal M, Lalit
    [J]. BIOMEDICAL RESEARCH-INDIA, 2017, 28 (04): : 1566 - 1573
  • [9] Monte Carlo Simulation of a 6MV Varian Truebeam Without Flattening Filter Linac
    Song, T.
    Zhou, L.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3819 - 3819
  • [10] Monte Carlo Commissioning of 6 MV Photon Beam of Varian Linear Accelerator Installed at INOR
    Bajwa, Saqib
    Gul, Attia
    Ahmed, Shahbaz
    Kakakhel, Muhammad Basim
    [J]. 2016 INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2016,