Serial Doppler echocardiographic evaluation of small-sized Sorin Bicarbon prostheses

被引:13
|
作者
De Carlo, M [1 ]
Milano, AD [1 ]
Nardi, C [1 ]
Mecozzi, G [1 ]
Bortolotti, U [1 ]
机构
[1] Univ Pisa, Sch Med, Cardiothorac Dept, I-56100 Pisa, Italy
来源
关键词
D O I
10.1016/S0022-5223(02)73395-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The Sorin Bicarbon prosthesis (Sorin Biomedica, Saluggia, Italy) is a bileaflet valve with curved-profile leaflets, a rolling hinge mechanism, and a pyrolytic carbon-coated titanium alloy housing and sewing ring. Although the Sorin Bicarbon prosthesis has been implanted in greater than 80,000 patients, and reference values on the hemodynamic performance of valve prostheses are needed to avoid patient-prosthesis mismatch, few Doppler echocardiographic data are available on the prosthesis in the aortic position. The aim of this study is to provide a detailed echocardiographic evaluation of the hemodynamic performance and regression of left ventricular hypertrophy after aortic valve replacement with the Sorin Bicarbon prosthesis. Methods: The study included 182 patients who received a 21-mm (n = 61) or 23-mm (n = 121) Sorin Bicarbon prosthesis for pure or prevalent aortic stenosis who underwent serial echocardiograms at 3, 6, and 12 months after aortic. valve replacement. Results: Mean and peak gradients significantly decreased (P < .001) during follow-up to values of 12 +/- 3 and 22 +/- 6 mm Hg for the 21-mm prosthesis and values of 11 +/- 4 and 19 +/- 6 mm Hg for the 23-mm prosthesis at I year. Left ventricular mass index showed a 17% decrease to 120 +/- 27 g/m(2) in recipients of the 21-mm prosthesis (P < .001),and a 21% decrease to 123 +/- 29 g/m(2) in recipients of the 23-mm prosthesis (P < .001). A larger prosthesis size was the only predictor of a higher left ventricular mass index regression. Among recipients of the 21-mm prosthesis, body surface area of greater than 1.85 m(2) was,associated with a lower regression of left ventricular mass index. The effective orifice area index was 1.00 +/- 0.11 and 1.08 +/- 0.14 cm(2)/m(2) in recipients of the 21-mm and 23-mm prostheses, respectively. Conclusions: Size 21 mm and 23 mm Sorin Bicarbon prostheses show low transprosthetic gradients, with significant reduction of left ventricular mass index during the first postoperative year. The reported effective orifice areas might be useful for aortic valve replacement in patients with a small aortic annulus to avoid patient-prosthesis mismatch.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [41] SERIAL ECHOCARDIOGRAPHIC AND DOPPLER EVALUATION OF LEFT-VENTRICULAR DIASTOLIC FILLING IN FULL-TERM NEONATES
    AREIAS, JC
    MEYER, R
    SCOTT, WA
    GOLDBERG, SJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (01): : 108 - 111
  • [42] Evaluation of the chemical quality of a new type of small-sized tomato cultivar, the plum tomato (Lycopersicon lycopersicum)
    Muratore, G
    Licciardello, F
    Maccarone, E
    ITALIAN JOURNAL OF FOOD SCIENCE, 2005, 17 (01) : 75 - 81
  • [43] SMALL-SIZED parabolic-trough solar collectors: Development of a test loop and evaluation of testing conditions
    Fernandez-Garcia, Aranzazu
    Valenzuela, Loreto
    Zarza, Eduardo
    Rojas, Esther
    Perez, Manuel
    Hernandez-Escobedo, Quetzalcoatl
    Manzano-Agugliaro, Francisco
    ENERGY, 2018, 152 : 401 - 415
  • [44] DOPPLER-ECHOCARDIOGRAPHIC COMPARISON OF SMALL (19MM) BILEAFLET AND PERICARDIAL HEART-VALVE PROSTHESES IN AORTIC POSITION
    GONZALEZJUANATEY, JR
    ACUNA, JMG
    AMARO, A
    CASTELO, V
    PEDREIRA, M
    BENGOECHEA, JG
    GIL, M
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 29 (01): : 29 - 35
  • [45] Repair of small-sized and medium-sized tympanic membrane perforation using butterfly cartilage graft: evaluation of take rate and hearing result
    Ahmed M.F.M.
    El-Sharkawy A.A.E.-R.
    El-Rahman W.M.A.
    The Egyptian Journal of Otolaryngology, 2017, 33 (1) : 5 - 8
  • [46] A New Method for Efficient Drive and Current Control of Small-sized Brushless DC Motor Experiments and its Evaluation
    Watanabe, Atsushi
    Yuta, Shin'ichi
    Ohya, Akihisa
    IECON 2010: 36TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2010,
  • [47] Evaluation of a photogrammetry-based scanner for measuring small-sized features in an additive manufacturing repair process chain
    Pirlo, Raniero
    Guerra, Maria Grazia
    Lavecchia, Fulvio
    Galantucci, Luigi Maria
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2025, 136 (11-12): : 5581 - 5598
  • [48] Evaluation and amelioration of computer-aided diagnosis with artificial neural networks utilizing small-sized sample sets
    Liu, K. Y.
    Smith, M. R.
    Fear, E. C.
    Rangayyan, R. M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (03) : 255 - 262
  • [49] Serial Doppler echocardiographic evaluation of Carpentier-Edwards pericardial valve dysfunction: Comparison with Ionescu-Shiley valve
    Kobayashi, Y
    Nagata, S
    Eishi, K
    Nakano, K
    Miyatake, K
    AMERICAN HEART JOURNAL, 1998, 135 (06) : 1086 - 1092
  • [50] Evaluation of locoregional invasiveness of small-sized non-small cell lung cancers by enhanced dual-energy computed tomography
    Shimamoto, Hironori
    Iwano, Shingo
    Umakoshi, Hiroyasu
    Kawaguchi, Koji
    Naganawa, Shinji
    CANCER IMAGING, 2016, 16