Serial Doppler echocardiographic evaluation of small-sized Sorin Bicarbon prostheses

被引:13
|
作者
De Carlo, M [1 ]
Milano, AD [1 ]
Nardi, C [1 ]
Mecozzi, G [1 ]
Bortolotti, U [1 ]
机构
[1] Univ Pisa, Sch Med, Cardiothorac Dept, I-56100 Pisa, Italy
来源
关键词
D O I
10.1016/S0022-5223(02)73395-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The Sorin Bicarbon prosthesis (Sorin Biomedica, Saluggia, Italy) is a bileaflet valve with curved-profile leaflets, a rolling hinge mechanism, and a pyrolytic carbon-coated titanium alloy housing and sewing ring. Although the Sorin Bicarbon prosthesis has been implanted in greater than 80,000 patients, and reference values on the hemodynamic performance of valve prostheses are needed to avoid patient-prosthesis mismatch, few Doppler echocardiographic data are available on the prosthesis in the aortic position. The aim of this study is to provide a detailed echocardiographic evaluation of the hemodynamic performance and regression of left ventricular hypertrophy after aortic valve replacement with the Sorin Bicarbon prosthesis. Methods: The study included 182 patients who received a 21-mm (n = 61) or 23-mm (n = 121) Sorin Bicarbon prosthesis for pure or prevalent aortic stenosis who underwent serial echocardiograms at 3, 6, and 12 months after aortic. valve replacement. Results: Mean and peak gradients significantly decreased (P < .001) during follow-up to values of 12 +/- 3 and 22 +/- 6 mm Hg for the 21-mm prosthesis and values of 11 +/- 4 and 19 +/- 6 mm Hg for the 23-mm prosthesis at I year. Left ventricular mass index showed a 17% decrease to 120 +/- 27 g/m(2) in recipients of the 21-mm prosthesis (P < .001),and a 21% decrease to 123 +/- 29 g/m(2) in recipients of the 23-mm prosthesis (P < .001). A larger prosthesis size was the only predictor of a higher left ventricular mass index regression. Among recipients of the 21-mm prosthesis, body surface area of greater than 1.85 m(2) was,associated with a lower regression of left ventricular mass index. The effective orifice area index was 1.00 +/- 0.11 and 1.08 +/- 0.14 cm(2)/m(2) in recipients of the 21-mm and 23-mm prostheses, respectively. Conclusions: Size 21 mm and 23 mm Sorin Bicarbon prostheses show low transprosthetic gradients, with significant reduction of left ventricular mass index during the first postoperative year. The reported effective orifice areas might be useful for aortic valve replacement in patients with a small aortic annulus to avoid patient-prosthesis mismatch.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [21] Evaluation of Small-Sized Platinum Resistance Thermometers with ITS-90 Characteristics
    K. Yamazawa
    K. Anso
    J. V. Widiatmo
    J. Tamba
    M. Arai
    International Journal of Thermophysics, 2011, 32 : 2397 - 2408
  • [22] Reliability Evaluation of Small-Sized Power Device with Low Thermal Resistance Structure
    Ito, Hiroaki
    Ohbu, Toshiharu
    Yamanari, Naoki
    2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [23] Evaluation of Small-Sized Platinum Resistance Thermometers with ITS-90 Characteristics
    Yamazawa, K.
    Anso, K.
    Widiatmo, J. V.
    Tamba, J.
    Arai, M.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (11-12) : 2397 - 2408
  • [24] DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF 90 NORMAL JUDE,SAINT MEDICAL AORTIC-VALVE PROSTHESES
    MARIBAS, P
    DIEBOLD, B
    VANETTI, A
    BICAL, O
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1990, 83 (11): : 1653 - 1658
  • [25] THROMBOLYTIC THERAPY FOR PROSTHETIC VALVE THROMBOSIS - A STUDY BASED ON SERIAL DOPPLER ECHOCARDIOGRAPHIC EVALUATION
    VASAN, RS
    KAUL, U
    SANGHVI, S
    KAMLAKAR, T
    NEGI, PC
    SHRIVASTAVA, S
    RAJANI, M
    VENUGOPAL, P
    WASIR, HS
    AMERICAN HEART JOURNAL, 1992, 123 (06) : 1575 - 1580
  • [26] DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF BJORK-SHILEY AND ST JUDE MEDICAL PROSTHESES IN THE MITRAL POSITION
    SHIGENOBU, M
    NAKAYAMA, H
    HISAMOCHI, K
    YAMAMOTO, N
    SENOO, Y
    TERAMOTO, S
    ACTA MEDICA OKAYAMA, 1991, 45 (05) : 325 - 332
  • [28] TRIALS ON THE INDUSTRIAL PROCESSING OF SMALL-SIZED CHINESE GOOSEBERRIES AND QUALITY EVALUATION OF THE FINISHED PRODUCTS
    ROSA, MD
    LERICI, C
    DALLAGLIO, G
    CARPI, G
    INDUSTRIA CONSERVE, 1980, 55 (04): : 286 - 293
  • [29] Automated ultrasonic scattering energy method for evaluation of small-sized cracking damage in concrete
    Kang, Minju
    Kim, Doyun
    Kim, Ryulri
    Hong, Jinyoung
    Min, Jiyoung
    Choi, Hajin
    MEASUREMENT, 2025, 239
  • [30] Evaluation of the efficiency of a small-sized electrothermal micro-thrusters with autonomous heating elements
    Blinov, V. N.
    Lukyanchik, A., I
    IV INTERNATIONAL SCIENTIFIC AND TECHNICAL CONFERENCE MECHANICAL SCIENCE AND TECHNOLOGY UPDATE (MSTU-2020), 2020, 1546