Serial Doppler echocardiographic evaluation of small-sized Sorin Bicarbon prostheses

被引:13
|
作者
De Carlo, M [1 ]
Milano, AD [1 ]
Nardi, C [1 ]
Mecozzi, G [1 ]
Bortolotti, U [1 ]
机构
[1] Univ Pisa, Sch Med, Cardiothorac Dept, I-56100 Pisa, Italy
来源
关键词
D O I
10.1016/S0022-5223(02)73395-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The Sorin Bicarbon prosthesis (Sorin Biomedica, Saluggia, Italy) is a bileaflet valve with curved-profile leaflets, a rolling hinge mechanism, and a pyrolytic carbon-coated titanium alloy housing and sewing ring. Although the Sorin Bicarbon prosthesis has been implanted in greater than 80,000 patients, and reference values on the hemodynamic performance of valve prostheses are needed to avoid patient-prosthesis mismatch, few Doppler echocardiographic data are available on the prosthesis in the aortic position. The aim of this study is to provide a detailed echocardiographic evaluation of the hemodynamic performance and regression of left ventricular hypertrophy after aortic valve replacement with the Sorin Bicarbon prosthesis. Methods: The study included 182 patients who received a 21-mm (n = 61) or 23-mm (n = 121) Sorin Bicarbon prosthesis for pure or prevalent aortic stenosis who underwent serial echocardiograms at 3, 6, and 12 months after aortic. valve replacement. Results: Mean and peak gradients significantly decreased (P < .001) during follow-up to values of 12 +/- 3 and 22 +/- 6 mm Hg for the 21-mm prosthesis and values of 11 +/- 4 and 19 +/- 6 mm Hg for the 23-mm prosthesis at I year. Left ventricular mass index showed a 17% decrease to 120 +/- 27 g/m(2) in recipients of the 21-mm prosthesis (P < .001),and a 21% decrease to 123 +/- 29 g/m(2) in recipients of the 23-mm prosthesis (P < .001). A larger prosthesis size was the only predictor of a higher left ventricular mass index regression. Among recipients of the 21-mm prosthesis, body surface area of greater than 1.85 m(2) was,associated with a lower regression of left ventricular mass index. The effective orifice area index was 1.00 +/- 0.11 and 1.08 +/- 0.14 cm(2)/m(2) in recipients of the 21-mm and 23-mm prostheses, respectively. Conclusions: Size 21 mm and 23 mm Sorin Bicarbon prostheses show low transprosthetic gradients, with significant reduction of left ventricular mass index during the first postoperative year. The reported effective orifice areas might be useful for aortic valve replacement in patients with a small aortic annulus to avoid patient-prosthesis mismatch.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [31] Evaluation of small-sized mounds formation mechanisms in China's Zhurong landing region
    Lin, Yu
    Zhao, Jiannan
    Wang, Le
    Huang, Jun
    Zhang, Liang
    Xiao, Long
    ICARUS, 2023, 389
  • [32] Evaluation on the performance and wear of blades in a small-sized high-density polyethylene shredder
    Jalisa, A. B.
    Wong, J. H.
    Karen, W. M. J.
    Liew, W. Y. H.
    Chua, B. L.
    Siambun, N. J. S.
    Melvin, G. J. H.
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2024, 55 (10) : 1426 - 1436
  • [34] Sustainability assessment framework for small-sized urban neighbourhoods: An application of fuzzy synthetic evaluation
    Haider, Husnain
    Hewage, Kasun
    Umer, Adil
    Ruparathna, Rajeev
    Chhipi-Shrestha, Gyan
    Culver, Keith
    Holland, Mark
    Kay, James
    Sadiq, Rehan
    SUSTAINABLE CITIES AND SOCIETY, 2018, 36 : 21 - 32
  • [35] Serial echocardiographic and Doppler evaluation of left ventricular systolic performance and diastolic filling in premature infants
    Harada, K
    Takahashi, Y
    Tamura, M
    Orino, T
    Takada, G
    EARLY HUMAN DEVELOPMENT, 1999, 54 (02) : 169 - 180
  • [36] Evaluation of cardiac functions in term small for gestational age newborns with mild growth retardation: A serial conventional and tissue Doppler imaging echocardiographic study
    Altin, Hakan
    Karaarslan, Sevim
    Karatas, Zehra
    Alp, Hayrullah
    Sap, Fatih
    Baysal, Tamer
    EARLY HUMAN DEVELOPMENT, 2012, 88 (09) : 757 - 764
  • [37] Evaluation of silicon photomultipliers for dual-mirror Small-Sized Telescopes of Cherenkov Telescope Array
    Asano, A.
    Berge, D.
    Bonanno, G.
    Bryan, M.
    Gebhardt, B.
    Grillo, A.
    Hidaka, N.
    Kachru, P.
    Lapington, J.
    Leach, S.
    Nakamura, Y.
    Okumura, A.
    Romeo, G.
    Ross, D.
    Stephan, M.
    Tajima, H.
    Timpanaro, M. C.
    White, R.
    Yamane, N.
    Zink, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 177 - 181
  • [38] Evaluation of platelet function under high shear condition in the small-sized collagen bead column
    Kaneko, M
    Takafuta, T
    Cuyun-Lira, O
    Satoh, K
    Arai, M
    Yatomi, Y
    Ozaki, Y
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 2005, 146 (02): : 64 - 75
  • [39] Challenges and potential strategies utilizing external data for efficacy evaluation in small-sized clinical trials
    Jiao, Feiran
    Chen, Yeh-Fong
    Min, Min
    Jimenez, Sara
    JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2022, 32 (01) : 21 - 33
  • [40] SERIAL DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF AN ACUTELY THROMBOSED MITRAL-VALVE PROSTHESIS DURING THROMBOLYTIC THERAPY
    CAMESAS, AM
    GELBER, P
    BODENHEIMER, M
    TYRAS, D
    ADAMICK, R
    AMERICAN HEART JOURNAL, 1987, 114 (06) : 1511 - 1513