Clinical and functional outcomes after type B-C (AO/OTA) distal humeral fractures treated with locking compression plates: a retrospective study

被引:1
|
作者
Citarelli, Carmine [1 ]
Sacchetti, Federico [1 ]
Agostini, Giulio [1 ]
Mattugini, Vittorio [1 ]
Andreani, Lorenzo [1 ]
Carmassi, Fabio [1 ]
Scaglione, Michelangelo [1 ]
Capanna, Rodolfo [1 ]
机构
[1] Univ Pisa, Unit Orthoped, Pisa, Italy
来源
MINERVA ORTHOPEDICS | 2021年 / 72卷 / 04期
关键词
Humerus; Fractures; bone; Retrospective studies; Locking compression plates; OPERATIVE TREATMENT; OLDER;
D O I
10.23736/S2784-8469.20.04002-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: B-C (AO/OTA) fractures of distal humerus are lesions difficult to treat with results that are not always satisfactory. The aim of this study was to evaluate the outcome of patients with this type of fractures treated at our institute. METHODS: A retrospective study considering 32 patients with mean age of 57.1 years (19-85) treated with open reduction and internal fixation (ORIF) for distal humerus articular fractures, 5 type B1. 1 type B2, 12 type C1, 4 type C2, 10 type C3 (AO/OTA), 29 closed fractures, 2 with grade I-II (Gustillo) of exposure, 1 with point exposure. Surgical exposures used are triceps-on and olecranon osteotomy, while the synthesis was performed with locking compression plates. The average follow-up was 42.7 months (79-9). The radiograms performed during the standard controls were evaluated and the Mayo Elbow Performance Score was used for functional evaluation. RESULTS: Average MEPS of 90.6 (55-100), excellent in 68.8%, good 18.7%, fair, 6.3% and poor 6.3%. Average flexion of 125.1 degrees(40-140 degrees) with an average deficiency of 11 degrees (0-40 degrees). All olecranial osteotomies healed, no pseudoarthrosis was found. Registered complications: 2 wound dehiscences, 7 cases with residual hypoesthesia in the territory of the ulnar nerve, 1 mobilization of a healed fracture screw, 3 cases with presence of joint ossifications and marked rigidity with subsequent surgical revision. CONCLUSIONS: ORIF with orthogonal construct and locking compression plates is an optimal technique for the treatment of distal humerus articular fractures. Associated with an early mobilization leads to an excellent functional result with a minimum rate of complications.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [1] Functional outcome of AO type C distal humeral fractures
    Gofton, WT
    MacDermid, JC
    Patterson, SD
    Faber, KJ
    King, GJW
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (02): : 294 - 308
  • [2] Clinical outcomes of treatment with locking compression plates for distal femoral fractures in a retrospective cohort
    Kiyono, Masahiro
    Noda, Tomoyuki
    Nagano, Hiroshi
    Maehara, Takashi
    Yamakawa, Yasuaki
    Mochizuki, Yusuke
    Uchino, Takahiko
    Yokoo, Suguru
    Demiya, Koji
    Saiga, Kenta
    Shimamura, Yasunori
    Ozaki, Toshifumi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
  • [3] Clinical outcomes of treatment with locking compression plates for distal femoral fractures in a retrospective cohort
    Masahiro Kiyono
    Tomoyuki Noda
    Hiroshi Nagano
    Takashi Maehara
    Yasuaki Yamakawa
    Yusuke Mochizuki
    Takahiko Uchino
    Suguru Yokoo
    Koji Demiya
    Kenta Saiga
    Yasunori Shimamura
    Toshifumi Ozaki
    Journal of Orthopaedic Surgery and Research, 14
  • [4] Functional Outcomes of Pre-Contoured Parallel Plates in Distal Humerus AO/OTA Type C Fractures in adults
    Shah, Syed Wasif Ali
    Bashir, Tariq
    Aslam, Muhammad Usman
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (04): : 906 - 908
  • [5] Are Outcomes Comparable for Repair of AO/OTA Type 13C1 and Type 13C2 Distal Humeral Fractures the
    Lee, Soonchul
    Baek, Eugene
    Kim, Minwook
    Kim, Junhan
    Lee, Hyunil
    Kim, Do Kyung
    Jang, Yoon
    Han, Soo-Hong
    CLINICS IN ORTHOPEDIC SURGERY, 2022, 14 (02) : 169 - 177
  • [6] Intramedullary nailing versus a locking compression plate for humeral shaft fracture (AO/OTA 12-A and B): A retrospective study
    Zhang, Ruipeng
    Yin, Yingchao
    Li, Shilun
    Hou, Zhiyong
    Jin, Lin
    Zhang, Yingze
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (07) : 1391 - 1397
  • [7] AO/OTA type C3 distal humeral fractures in patients aged 75 years and older: Is ORIF with double precontoured anatomical locking plates a reliable treatment?
    Aguado, Hector J.
    Mingo-Robinet, Juan
    Garcia-Virto, Virginia
    SanJose-Pardo, Inigo
    Pais, Sergio
    Alvarez-Ramos, Begona A.
    Simon-Perez, Clarisa
    Noriega, David C.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54
  • [8] Comparative study of functional outcomes between OTA/AO type C, Gustilo type I/II open fractures and closed fractures of the distal humerus treated by open reduction and internal fixation
    Chen Chen
    Dan Xiao
    Ting Li
    Maoqi Gong
    Yejun Zha
    Kehan Hua
    Weitong Sun
    Shangwei Ji
    Xieyuan Jiang
    BMC Musculoskeletal Disorders, 22
  • [9] Comparative study of functional outcomes between OTA/AO type C, Gustilo type I/II open fractures and closed fractures of the distal humerus treated by open reduction and internal fixation
    Chen, Chen
    Xiao, Dan
    Li, Ting
    Gong, Maoqi
    Zha, Yejun
    Hua, Kehan
    Sun, Weitong
    Ji, Shangwei
    Jiang, Xieyuan
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [10] Functional outcome of type 13 C2 distal humerus fractures treated with precontoured locking plates
    Gowtam, S. V.
    Gunaki, Ravindra B.
    FORMOSAN JOURNAL OF SURGERY, 2021, 54 (03) : 85 - 90