Serial intravascular ultrasonographic measurements after implantation of biodegradable polymer-coated stents in porcine coronary arteries

被引:2
|
作者
Fröhlich, G
Strehblow, C
Sperker, W
Yahya, N
Shirazi, M
Hevesi, A
Garamvölgyi, R
Hadjiev, J
Scherzer, T
Glogar, D
Gyöngyösi, M
机构
[1] Univ Vienna, Dept Cardiol, A-1090 Vienna, Austria
[2] Univ Kaposvar, Inst Diagnost Imaging & Radiat Oncol, Kaposvar, Hungary
关键词
coronary stent; drug-eluting stent; biodegradable polymer coating; intimal hyperplasia; in-stent restenosis;
D O I
10.1097/00019501-200308000-00009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Biodegradable stent coatings provide a potential for local drug delivery at the time of vascular injury, while possible tissue toxicity is avoided through constant degradation, leaving behind a bare metal stent. Design Serial three-dimensional (3D) intravascular ultrasonographic results on bare Megaflex stents; and biodegradable polymer-coated Megaflex stents (Hyper stents) (Eurocor, Bonn, Germany) were compared 1 and 4 weeks after intracoronary implantation in pigs. Methods Under general anaesthesia, the left anterior descending and circumflex coronary arteries of domestic pigs were stented with Megaflex and Hyper stents, using right femoral artery access. Control coronary angiography and intravascular ultrasonography (IVUS) were performed 1 and 4 weeks after stent implantation using left femoral artery access and right carotid artery access. After recording of angiographic and IVUS data, the pigs were allowed to recover. Results The 1- and 4-week IVUS follow-ups revealed less neointima formation with Hyper stents than with Megaflex stents: 1-week intimal volume, 11.8 +/- 0.93 compared with 15.02 +/- 4.18 mm(3), P=0.065; intimal area, 0.81 +/- 0.06 compared with 1.1 +/- 0.16 mm(2), p = 0.003; maximal intimal thickness, 0.12 +/- 0.01 compared with 0.14 +/- 0.02 mm, P =0.049; 4-week intimal volume, 12.4 +/- 1.77 compared with 27.32 +/- 12.79 mm(3), P =0.016; intimal area, 0.82 +/- 0.12 compared with 1.95 +/- 0.65 mm(2), P=0.003; and maximal intimal thickness, 0.13 +/- 0.04 compared with 0.30 +/- 0.10 m m, P = 0.003. Conclusions Implantation of biodegradable polymer-coated (Hyper) stents results in significantly less neointima formation 1 and 4 weeks after intracoronary implantation than with bare Megaflex stents. Taking advantage of the good collateralization of femoral and carotid arteries of pigs, the use of different arterial accesses allows serial angiographic and 3D IVUS measurements on neointimal development without sacrificing the animals.
引用
收藏
页码:409 / 412
页数:4
相关论文
共 50 条
  • [41] The outcome of ultrathin-strut biodegradable polymer-coated sirolimus-eluting stents in coronary artery disease patients - A feasibility study
    Panduranga, Prashanth
    Mohammed, Azzam
    HEART VIEWS, 2023, 24 (01): : 1 - 5
  • [42] Biodegradable polymer-coated versus durable polymer-coated sirolimus-eluting stents: the final 5-year outcomes of the I-LOVE-IT 2 trial
    Xu, Kai
    Xu, Bo
    Guan, Changdong
    Jing, Quanmin
    Zheng, Qiangsun
    Li, Xueqi
    Zhao, Xianxian
    Wang, Haichang
    Zhao, Xuezhong
    Li, Yi
    Li, Jing
    Yang, Yuejin
    Han, Yaling
    EUROINTERVENTION, 2021, 16 (18) : E1518 - +
  • [43] Bare Metal Stents on Resveratrol-Coated Balloons in Porcine Coronary and Peripheral Arteries
    Kamann, Stefanie
    Haase, Tobias
    Stolzenburg, Nicola
    Loechel, Melanie
    Peters-Berg, Daniel
    Schuett, Denise
    Schnorr, Joerg
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (23)
  • [44] Effect of stents coated by an autologous vein graft on intimal hyperplasia in porcine coronary arteries
    Toutouzas, K
    Stefanadis, C
    Tsiamis, E
    Vlachopoulos, C
    Vaina, S
    Tsekoura, D
    Haldi, L
    Kostomitsopoulos, N
    Toutouzas, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 414A - 414A
  • [45] HOW LONG ARE STENTS NEEDED IN CORONARY-ARTERIES AFTER IMPLANTATION
    WANG, MU
    TAMAI, H
    DOI, T
    HSU, YS
    UEDA, K
    MOTOHARA, S
    UEHATA, H
    IGAKI, K
    MATSUSHIMA, M
    TSUJII, T
    CIRCULATION, 1995, 92 (08) : 2562 - 2562
  • [46] LONG-TERM EFFECTS OF BIODEGRADABLE VERSUS DURABLE POLYMER-COATED SIROLIMUS-ELUTING STENTS ON CORONARY ARTERIAL WALL MORPHOLOGY ASSESSED BY VIRTUAL HISTOLOGY INTRAVASCULAR ULTRASOUND IN PATIENTS WITH ACUTE CORONARY SYNDROME
    Jin Zhi-Geng
    Liu Hui-Liang
    Luo Jian-Ping
    Ma Dong-Xing
    Yang Sheng-Li
    Liu Ying
    Han Wei
    Jing Li-Min
    Meng Rong-Ying
    HEART, 2011, 97
  • [47] Thin, Very Thin, or Ultrathin Strut Biodegradable or Durable Polymer-Coated Drug-Eluting Stents
    Buiten, Rosaly A.
    Ploumen, Eline H.
    Zocca, Paolo
    Doggen, Carine J. M.
    Danse, Peter W.
    Schotborgh, Carl E.
    Scholte, Martijn
    van Houwelingen, K. Gert
    Stoel, Martin G.
    Hartmann, Marc
    Gin, R. Melvyn Tjon Joe
    Somi, Samer
    Linssen, Gerard C. M.
    Kok, Marlies M.
    von Birgelen, Clemens
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (17) : 1650 - 1660
  • [48] A randomised comparison of biodegradable polymer- and permanent polymer-coated platinum-chromium everolimus-eluting coronary stents in China: the EVOLVE China study
    Han, Yaling
    Liu, Haiwei
    Yang, Yuejin
    Zhang, Jian
    Xu, Kai
    Fu, Guosheng
    Su, Xi
    Jiang, Tiemin
    Pang, Wenyue
    Chen, Jiyan
    Yuan, Zuyi
    Li, Hui
    Wang, Haichang
    Hong, Tao
    Liu, Huiliang
    Sun, Fucheng
    Allocco, Dominic J.
    Zhang, Mingdong
    Dawkins, Keith D.
    EUROINTERVENTION, 2017, 13 (10) : 1210 - 1217
  • [49] Early vascular responses to abluminal biodegradable polymer-coated versus circumferential durable polymer-coated newer-generation drug-eluting stents in humans: a pathologic study
    Kawagoe, Y.
    Otuka, F.
    Onozuka, D.
    Ueda, H.
    Ikeda, Y.
    Ogo, K.
    Matsumoto, M.
    Amemiya, K.
    Asaumim, Y.
    Kataoka, Y.
    Nishimura, K.
    Miyamoto, Y.
    Noguchi, T.
    Hatakeyama, K.
    Yasuda, S.
    EUROPEAN HEART JOURNAL, 2022, 43 : 2056 - 2056
  • [50] Decrease Of Neointimal Proliferation After Implantation of Activated Protein C (Xigris)-Coated Stent In Porcine Coronary Arteries
    Gyongyosi, Mariann
    Nyolczas, Noemi
    Posa, Aniko
    Petrasi, Zsolt
    Petnehazy, Oers
    Glogar, Dietmar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A73 - A73