The outcome of ultrathin-strut biodegradable polymer-coated sirolimus-eluting stents in coronary artery disease patients - A feasibility study

被引:0
|
作者
Panduranga, Prashanth [1 ]
Mohammed, Azzam [1 ]
机构
[1] Royal Hosp, Natl Heart Ctr, Dept Cardiol, Post Box 1331, Muscat 111, Oman
来源
HEART VIEWS | 2023年 / 24卷 / 01期
关键词
Biodegradable polymer; stent; ultrathin strut; OPTICAL COHERENCE TOMOGRAPHY; HYPERSENSITIVITY; THROMBOSIS; RISK;
D O I
10.4103/heartviews.heartviews_46_22
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Drug-eluting coronary stents with ultrathin struts and biodegradable polymers have been shown to reduce inflammation, neointimal proliferation, and thrombus formation, leading to less early and late complications in patients with coronary artery disease as compared to thinner strut and durable polymer second-generation stents. In Oman, currently, second-generation stents are used for all patients.Objective: The purpose of this feasibility study was to evaluate the clinical safety and performance of ultrathin-strut (60 mu m) biodegradable polymer-coated sirolimus-eluting stents in an all-comers patient population.Methods: This was a prospective, observational, single-center, and single-arm investigator-initiated study from August 2018 to August 2019. Inclusion criteria: 18 years of age, patients with symptomatic coronary artery disease indicated for percutaneous coronary intervention, and stenting of at least one coronary lesion. All patients were followed clinically or telephonically at 12 months after the index procedure.Results: A total of 88 patients were recruited in the study, but 10 patients were lost to follow-up and hence excluded from the analysis. The overall mean age was 63 +/- 13 years and 78% were males. The main comorbid conditions were hypertension (58%), diabetes mellitus (49%), and hyperlipidemia (26%). Fifty-three percent presented with unstable angina or non-ST elevation myocardial infarction (MI), 10% with ST elevation MI, recent MI 16%, 18% with stable angina, and 1.3% in cardiogenic shock. The mean left ventricular ejection fraction of the cohort was 46 +/- 14%. Angiographically, Type A lesions were seen in 25%, Type B in 32%, and Type C in 42%. Left anterior descending stenting was done in 44%, right coronary artery in 32%, left circumflex artery in 14%, left main in 5%, and graft stenting in 4%. Device success was 96%. Procedural success was seen in 97% of patients. At 1-year follow-up, 93% were asymptomatic; overall device-oriented clinical events were 6.8% including cardiac death in 2.7%, target-vessel MI in 2.7%, and target-lesion revascularization in 1.3% which all occurred in uncontrolled diabetic patients.Conclusions: At index admission and 1 year, ultrathin-strut biodegradable polymer-coated sirolimus-eluting stent study showed low device-related adverse clinical events which are comparable to published data for the second-generation stents. This feasibility study shows that these stents can be used in all types of stent-indicated patients with added advantages of biodegradable polymer and ultrathin struts. In addition, measures to prevent, diagnose, and control diabetes need to be taken in Oman as this cohort of patients develop ST after stenting.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [1] Real-World Use Of Ultrathin-Strut Biodegradable Polymer-Coated Sirolimus-Eluting Stents In Patients With Coronary Artery Disease: 6-Month Clinical Outcomes
    Ajmera, Prakash
    Pothineni, Ramesh
    Chawla, Kamal Kumar
    Mantravadi, Sai Sudhakar
    Jariwala, Pankaj Vinod
    Vijan, Vinod
    Vijan, Vikrant
    VASCULAR HEALTH AND RISK MANAGEMENT, 2019, 15 : 439 - 447
  • [2] Thin, very thin, or ultrathin-strut biodegradable or durable polymer-coated drug-eluting stents
    Buiten, Rosaly A.
    Zocca, Paolo
    von Birgelen, Clemens
    CURRENT OPINION IN CARDIOLOGY, 2020, 35 (06) : 705 - 711
  • [3] Ultrathin Strut Biodegradable Polymer-Coated Sirolimus-Eluting Coronary Stents: Patient-Level Pooled Analysis From Two Indian Registries
    Pothineni, Ramesh Babu
    Ajmera, Prakash
    Chawla, Kamal Kumar
    Mantravadi, Sai Sudhakar
    Pathak, Abhijit
    Inamdar, Manohar K.
    V. Jariwala, Pankaj
    Vijan, Vikrant
    Vijan, Vinod
    Potdar, Anil
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [4] Efficacy and safety of domestic biodegradable polymer sirolimus-eluting stents and durable polymer sirolimus-eluting stents in the treatment of coronary artery disease
    Fang, Yi
    Bin, Wang
    Jing, Li
    Qiu Miaohan
    Han Yaling
    Shuang, Wang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (16) : C106 - C107
  • [5] Initial Experience With Ultrathin Strut Biodegradable Polymer-Coated Everolimus-Eluting Coronary Stent in Coronary Artery Disease Patients
    Sivaprasad, K.
    Arneja, Jaspal Singh
    Kumar, Dilip
    Arora, Parneesh
    Balakrishnan, Madanmohan
    Raghu, T. R.
    Davidson, Deepak
    Roy, Sanjeeb
    Chandra, Subhash
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B220 - B220
  • [6] Clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease
    Patted, Suresh, V
    Thakkar, Ashok S.
    ARYA ATHEROSCLEROSIS, 2020, 16 (03) : 130 - 135
  • [7] Preferable vascular healing of ultrathin strut biodegradable-polymer sirolimus-eluting stents in patients with acute coronary syndrome
    Akito Kawamura
    Yasuyuki Egami
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Hitoshi Nakamura
    Yutaka Matsuhiro
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masamichi Yano
    Masami Nishino
    Jun Tanouchi
    Cardiovascular Intervention and Therapeutics, 2022, 37 : 681 - 690
  • [8] Preferable vascular healing of ultrathin strut biodegradable-polymer sirolimus-eluting stents in patients with acute coronary syndrome
    Kawamura, Akito
    Egami, Yasuyuki
    Kawanami, Shodai
    Sugae, Hiroki
    Ukita, Kohei
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Nishino, Masami
    Tanouchi, Jun
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (04) : 681 - 690
  • [9] Ultrathin strut biodegradable-polymer sirolimus-eluting stents: being wary or going with the flow?
    Cassese, Salvatore
    Lahmann, Anna Lena
    Joner, Michael
    JOURNAL OF THORACIC DISEASE, 2018, 10 (02) : 688 - 692
  • [10] Thin Composite -Wire -Strut Zotarolimus-Eluting Stents Versus Ultrathin-Strut Sirolimus-Eluting Stents in BIONYX at 2 Years
    Buiten, Rosaly A.
    Ploumen, Eline H.
    Zocca, Paolo
    Doggen, Carine J. M.
    Jessurun, Gillian A. J.
    Schotborgh, Carl E.
    Roguin, Ariel
    Danse, Peter W.
    Benit, Edouard
    Aminian, Adel
    van Houwelingen, K. Gert
    Schramm, Alexander R.
    Stoel, Martin G.
    Somi, Samer
    Hartmann, Marc
    Linssen, Gerard C. M.
    von Birgelen, Clemens
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (09) : 1100 - 1109