Serial intravascular ultrasonographic measurements after implantation of biodegradable polymer-coated stents in porcine coronary arteries

被引:2
|
作者
Fröhlich, G
Strehblow, C
Sperker, W
Yahya, N
Shirazi, M
Hevesi, A
Garamvölgyi, R
Hadjiev, J
Scherzer, T
Glogar, D
Gyöngyösi, M
机构
[1] Univ Vienna, Dept Cardiol, A-1090 Vienna, Austria
[2] Univ Kaposvar, Inst Diagnost Imaging & Radiat Oncol, Kaposvar, Hungary
关键词
coronary stent; drug-eluting stent; biodegradable polymer coating; intimal hyperplasia; in-stent restenosis;
D O I
10.1097/00019501-200308000-00009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Biodegradable stent coatings provide a potential for local drug delivery at the time of vascular injury, while possible tissue toxicity is avoided through constant degradation, leaving behind a bare metal stent. Design Serial three-dimensional (3D) intravascular ultrasonographic results on bare Megaflex stents; and biodegradable polymer-coated Megaflex stents (Hyper stents) (Eurocor, Bonn, Germany) were compared 1 and 4 weeks after intracoronary implantation in pigs. Methods Under general anaesthesia, the left anterior descending and circumflex coronary arteries of domestic pigs were stented with Megaflex and Hyper stents, using right femoral artery access. Control coronary angiography and intravascular ultrasonography (IVUS) were performed 1 and 4 weeks after stent implantation using left femoral artery access and right carotid artery access. After recording of angiographic and IVUS data, the pigs were allowed to recover. Results The 1- and 4-week IVUS follow-ups revealed less neointima formation with Hyper stents than with Megaflex stents: 1-week intimal volume, 11.8 +/- 0.93 compared with 15.02 +/- 4.18 mm(3), P=0.065; intimal area, 0.81 +/- 0.06 compared with 1.1 +/- 0.16 mm(2), p = 0.003; maximal intimal thickness, 0.12 +/- 0.01 compared with 0.14 +/- 0.02 mm, P =0.049; 4-week intimal volume, 12.4 +/- 1.77 compared with 27.32 +/- 12.79 mm(3), P =0.016; intimal area, 0.82 +/- 0.12 compared with 1.95 +/- 0.65 mm(2), P=0.003; and maximal intimal thickness, 0.13 +/- 0.04 compared with 0.30 +/- 0.10 m m, P = 0.003. Conclusions Implantation of biodegradable polymer-coated (Hyper) stents results in significantly less neointima formation 1 and 4 weeks after intracoronary implantation than with bare Megaflex stents. Taking advantage of the good collateralization of femoral and carotid arteries of pigs, the use of different arterial accesses allows serial angiographic and 3D IVUS measurements on neointimal development without sacrificing the animals.
引用
收藏
页码:409 / 412
页数:4
相关论文
共 50 条
  • [21] Comparison of coronary angioscopic findings 8 months after stent implantation between two kinds of biodegradable polymer-coated and one durable polymer-coated drug-eluting stent
    Yasumura, Keisuke
    Shutta, Ryu
    Matsunaga-Lee, Yasuharu
    Nakamura, Daisuke
    Yano, Masamichi
    Yamato, Masaki
    Egami, Yasuyuki
    Sakata, Yasushi
    Nishino, Masami
    Tanouchi, Jun
    CORONARY ARTERY DISEASE, 2021, 32 (02) : 91 - 95
  • [22] Cobalt-chromium stents in porcine coronary arteries: angiographic and ultrasonographic outcomes
    Buszman, P.
    Zurakowski, A.
    Milewski, K.
    EUROPEAN HEART JOURNAL, 2005, 26 : 417 - 417
  • [23] Different Vessel Healing Patterns Following Delivery of Everolimus and Paclitaxel Eluted from Biodegradable Polymer Coated Stents Implanted in Porcine Coronary Arteries
    Buszman, Piotr
    Milewski, Krzysztof
    Pajak, Jacek
    Jelonek, Michal
    Gwiazdowka-Olech, Beata
    Suchodolska, Agata
    Pawel, Gasior
    Wojakowski, Wojciech
    Tellez, Armando
    Granada, Juan
    Buszman, Pawel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B167 - B167
  • [24] Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation
    Koppara, Tobias
    Joner, Michael
    Bayer, Gerd
    Steigerwald, Kristin
    Diener, Tobias
    Wittchow, Eric
    THROMBOSIS AND HAEMOSTASIS, 2012, 107 (06) : 1161 - 1171
  • [25] Phosphorylcholine coated stents: Angiographic and morphometric assessment in porcine coronary arteries
    Malik, N
    Gunn, J
    Newman, C
    Crossman, DC
    Cumberland, DC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 414A - 414A
  • [26] Long-Term Efficacy of Biodegradable Metal-Polymer Composite Stents After the First and the Second Implantations into Porcine Coronary Arteries
    Li, Xin
    Zhang, Wanqian
    Lin, Wenjiao
    Qiu, Hong
    Qi, Yongli
    Ma, Xun
    Qi, Haiping
    He, Yao
    Zhang, Hongjie
    Qian, Jie
    Zhang, Gui
    Gao, Runlin
    Zhang, Deyuan
    Ding, Jiandong
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (13) : 15703 - 15715
  • [27] Three-dimensional intravascular ultrasound assessment after the implantation of estrogen-eluting PC-coated stents, in human coronary arteries
    Costa, MA
    Sousa, JEM
    Abizaid, AA
    Abizaid, AS
    Staico, R
    Mattos, LA
    Fares, F
    Pinto, I
    Bass, TA
    Sousa, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 5A - 6A
  • [28] The serial intravascular ultrasound findings of a new biodegradable self-expanding coronary stents
    Komori, H
    Tamai, H
    Igaki, K
    Kyo, E
    Kosuga, K
    Hata, T
    Okada, M
    Nakamura, T
    Tsuji, T
    Takeda, S
    Motohara, S
    Uehata, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 1A - 1A
  • [29] Serial Optical Coherence Tomography Evaluation at 6, 12, and 24 Months After Biolimus A9-Eluting Biodegradable Polymer-Coated Stent Implantation
    Konishi, Akihide
    Shinke, Toshiro
    Otake, Hiromasa
    Takaya, Tomofumi
    Osue, Tsuyoshi
    Kinutani, Hiroto
    Kuroda, Masaru
    Takahashi, Hachidai
    Terashita, Daisuke
    Shite, Junya
    Hirata, Ken-ichi
    CANADIAN JOURNAL OF CARDIOLOGY, 2015, 31 (08) : 980 - 988
  • [30] Chronic arterial responses to stent implantation: A serial intravascular ultrasound analysis of Palmaz-Schatz stents in native coronary arteries
    Hoffmann, R
    Mintz, GS
    Popma, JJ
    Satler, LF
    Pichard, AD
    Kent, KM
    Walsh, C
    Mackell, P
    Leon, MB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) : 1134 - 1139