Comparison of doses for bedside examinations of the chest with conventional screen-film and computed radiography: Results of a randomized controlled trial

被引:27
|
作者
Weatherburn, GC [1 ]
Bryan, S [1 ]
Davies, JG [1 ]
机构
[1] Brunel Univ, Hlth Econ Res Grp, Uxbridge UB8 3PH, Middx, England
关键词
radiations; exposure to patients and personnel; radiography; bedside; comparative studies; computer-assisted; storage phosphor; thorax; abnormalities;
D O I
10.1148/radiology.217.3.r00dc12707
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the radiation doses received by patients during bedside chest radiography when a computed radiography system was used and when a 400-speed screen-film system was used. MATERIALS AND METHODS: A randomized controlled trial was performed whereby all patients who were admitted to an intensive care unit were randomly assigned at admission to have all radiographic chest images obtained with either computed or conventional screen-film radiography. Doses were measured for 1 year, during which 269 patients underwent imaging. For these patients, surface entry doses were measured by means of individual thermoluminescent dosimeters placed on the skin at the center of the radiation beam. In addition, data were collected relating to the patient and examination characteristics, as well as to repeat examinations. Effective doses were calculated. RESULTS: The patients in the two arms of the study were well matched. The surface entry doses were higher in the computed radiography group (median, 0.21 mGy for computed radiography and 0.16 mGy for conventional radiography), and the effective doses were also higher (median, 0.036 mSv for computed radiography and 0.027 mSv for conventional radiography). Fewer examinations were repeated when computed radiography was used. CONCLUSION: When computed radiography was used, patient doses increased. The speed of this computed radiography system, which uses phosphor plate imaging, equates approximately to a 300-speed screen-film system.
引用
收藏
页码:707 / 712
页数:6
相关论文
共 50 条
  • [41] Comparison of testing of collimator and beam alignment, focal spot size with slit camera, and tube current consistency using computed radiography and conventional screen-film systems
    Meechai, Tipvimol
    Chousangsuntorn, Khaisang
    Owasiriku, Wiwat
    Mongkolsuk, Manus
    Iampa, Woranut
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 160 - 169
  • [42] Interobserver agreement and performance score comparison in quality control using a breast phantom: screen-film mammography vs computed radiography
    Kazuhiro Shimamoto
    Mitsuru Ikeda
    Hiroko Satake
    Satoko Ishigaki
    Akiko Sawaki
    Takeo Ishigaki
    European Radiology, 2002, 12 : 2192 - 2197
  • [43] Interobserver agreement and performance score comparison in quality control using a breast phantom: screen-film mammography vs computed radiography
    Shimamoto, K
    Ikeda, M
    Satake, H
    Ishigaki, S
    Sawaki, A
    Ishigaki, T
    EUROPEAN RADIOLOGY, 2002, 12 (09) : 2192 - 2197
  • [44] Performance of a new digital flat panel detector in the detection of artificial bone lesions: A comparison with conventional screen-film radiography and phosphor-storage radiography
    Ludwig, K
    Lenzen, H
    Kamm, K
    Link, TM
    Diederich, S
    Wormanns, D
    RADIOLOGY, 2000, 217 : 517 - 517
  • [45] Comparison of model predictions of image quality with results of clinical trials in chest and lumbar spine screen-film imaging
    Sandborg, M
    McVey, G
    Dance, DR
    Carlsson, GA
    RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 173 - 176
  • [46] Detection of CT-proved pulmonary nodules: Comparison of selenium-based digital and conventional screen-film chest radiographs
    Woodard, PK
    Slone, RM
    Sagel, SS
    Fleishman, MJ
    Gutierrez, FR
    Reiker, GG
    Pilgram, TK
    Jost, RG
    RADIOLOGY, 1998, 209 (03) : 705 - 709
  • [47] COST COMPARISON BETWEEN STORAGE-PHOSPHOR COMPUTED RADIOGRAPHY AND CONVENTIONAL FILM-SCREEN RADIOGRAPHY IN INTENSIVE-CARE MEDICINE
    PETERS, PE
    DYKSTRA, DE
    WIESMANN, W
    SCHLUCHTERMANN, J
    ADAM, D
    RADIOLOGE, 1992, 32 (11): : 536 - 540
  • [48] Comparison of image quality and patient dose for chest x-ray examinations on conventional and low cost computed radiography systems
    Muhogora, W. E.
    Trianni, A.
    Toso, F.
    Devetti, A.
    Padovani, R.
    Msaki, P.
    Kazema, R.
    RADIOGRAPHY, 2012, 18 (04) : 275 - 278
  • [49] Performance of a flat-panel detector in detecting artificial bone lesions: Comparison with conventional screen-film and storage-phosphor radiography
    Ludwig, K
    Lenzen, H
    Kamm, KF
    Link, TM
    Diederich, S
    Wormanns, D
    Heindel, W
    RADIOLOGY, 2002, 222 (02) : 453 - 459
  • [50] Performance of a flat-panel detector in the detection of artificial erosive changes: comparison with conventional screen-film and storage-phosphor radiography
    Ludwig, K
    Henschel, A
    Bernhardt, TM
    Lenzen, H
    Wormanns, D
    Diederich, S
    Heindel, W
    EUROPEAN RADIOLOGY, 2003, 13 (06) : 1316 - 1323