Comparison of doses for bedside examinations of the chest with conventional screen-film and computed radiography: Results of a randomized controlled trial

被引:27
|
作者
Weatherburn, GC [1 ]
Bryan, S [1 ]
Davies, JG [1 ]
机构
[1] Brunel Univ, Hlth Econ Res Grp, Uxbridge UB8 3PH, Middx, England
关键词
radiations; exposure to patients and personnel; radiography; bedside; comparative studies; computer-assisted; storage phosphor; thorax; abnormalities;
D O I
10.1148/radiology.217.3.r00dc12707
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the radiation doses received by patients during bedside chest radiography when a computed radiography system was used and when a 400-speed screen-film system was used. MATERIALS AND METHODS: A randomized controlled trial was performed whereby all patients who were admitted to an intensive care unit were randomly assigned at admission to have all radiographic chest images obtained with either computed or conventional screen-film radiography. Doses were measured for 1 year, during which 269 patients underwent imaging. For these patients, surface entry doses were measured by means of individual thermoluminescent dosimeters placed on the skin at the center of the radiation beam. In addition, data were collected relating to the patient and examination characteristics, as well as to repeat examinations. Effective doses were calculated. RESULTS: The patients in the two arms of the study were well matched. The surface entry doses were higher in the computed radiography group (median, 0.21 mGy for computed radiography and 0.16 mGy for conventional radiography), and the effective doses were also higher (median, 0.036 mSv for computed radiography and 0.027 mSv for conventional radiography). Fewer examinations were repeated when computed radiography was used. CONCLUSION: When computed radiography was used, patient doses increased. The speed of this computed radiography system, which uses phosphor plate imaging, equates approximately to a 300-speed screen-film system.
引用
收藏
页码:707 / 712
页数:6
相关论文
共 50 条
  • [31] COMPARISON OF STEREOSCOPICALLY ACQUIRED CHEST IMAGES BY USING STORAGE PHOSPHOR RADIOGRAPHY AND AN ASYMMETRIC SCREEN-FILM SYSTEM
    HARTMAN, TE
    AUGHENBAUGH, GL
    BROWN, LR
    HARMS, GF
    KARSELL, PR
    MILLER, WE
    RADIOLOGY, 1995, 197 : 341 - 341
  • [32] COMPARISON OF STEREOSCOPICALLY ACQUIRED CHEST IMAGES WITH USE OF STORAGE PHOSPHOR RADIOGRAPHY AND AN ASYMMETRIC SCREEN-FILM SYSTEM
    HARTMAN, TE
    AUGHENBAUGH, GL
    BROWN, LR
    HARMS, GF
    KARSELL, PR
    MILLER, WE
    RADIOLOGY, 1995, 197 : 525 - 525
  • [33] Comparison of selenium-based digital and conventional screen-film chest radiographs for the detection of pulmonary nodules
    Woodard, PK
    Slone, RM
    Sagel, SS
    Fleishman, MJ
    Gutierrez, FR
    Reiker, GG
    RADIOLOGY, 1997, 205 : 1633 - 1633
  • [34] X-RAY EXAMINATIONS OF PERIPHERAL JOINTS - COMPARISON OF DIGITAL LUMINESCENT RADIOGRAPHY (DLR) AND SCREEN-FILM SYSTEM COMBINATIONS
    KRUG, B
    FISCHBACH, R
    HERRMANN, S
    DIETLEIN, M
    KUPPER, T
    DOLKEN, W
    HARNISCHMACHER, U
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (02): : 133 - 140
  • [35] COMPARISON OF THE LOW-CONTRAST DETECTABILITY OF A SCREEN-FILM SYSTEM AND 3RD-GENERATION COMPUTED RADIOGRAPHY
    COOK, LT
    INSANA, MF
    MCFADDEN, MA
    HALL, TJ
    COX, GG
    MEDICAL PHYSICS, 1994, 21 (05) : 691 - 695
  • [36] VOLUME DETECTION THRESHOLD - QUANTITATIVE COMPARISON OF COMPUTED RADIOGRAPHY AND SCREEN-FILM RADIOGRAPHY IN DETECTION OF PNEUMOTHORACES IN AN ANIMAL-MODEL THAT SIMULATES THE NEONATE
    DON, S
    COHEN, MD
    KRUGER, RA
    WINKLER, TA
    KATZ, BP
    LI, W
    DREESEN, RG
    KENNAN, N
    TARVER, R
    KLATTE, EC
    RADIOLOGY, 1995, 194 (03) : 727 - 730
  • [37] A prospective randomized clinical trial comparing two film-screen systems for chest radiography
    Lefcoe, MS
    Cunningham, IA
    Vanderburgh, LC
    Sparrow, RK
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1996, 47 (03): : 213 - 219
  • [38] Patient dose reduction with a digital amorphous silicon flat panel detector compared to conventional screen-film and phosphor-based computed radiography systems in chest imaging
    Bacher, K
    Smeets, PV
    De Hauwere, A
    Verstraete, KL
    Thierens, H
    RADIOLOGY, 2002, 225 : 643 - 643
  • [39] Image quality and dose comparison among screen-film, computed, and CT scanned projection radiography: Applications to CT urography
    McCollough, CH
    Bruesewitz, MR
    Vrtiska, TJ
    King, BF
    LeRoy, AJ
    Quam, JP
    Hattery, RR
    RADIOLOGY, 2001, 221 (02) : 395 - 403
  • [40] Comparison of a newly developed dual screen computed radiography (CR) system with conventional single screen CR in the evaluation of the chest radiograph
    Sabloff, BS
    Lai, C
    Munden, RF
    Gladish, GW
    Truong, MT
    Shaw, CC
    RADIOLOGY, 2002, 225 : 382 - 382