Study on Reciprocal Models for Magneto-Acousto-Electrical Tomography With Coil Detection

被引:1
|
作者
Gong, Likun [1 ]
Yang, Lan [1 ]
Yang, Siyi [1 ]
Wang, Yuanze [1 ]
Zhong, Minjing [1 ]
Guo, Liang [2 ]
机构
[1] China Univ Petr, Coll Informat & Control Engn, Qingdao 266580, Peoples R China
[2] China Univ Petr, Coll Control Sci & Engn, Qingdao 266580, Peoples R China
关键词
MAET-MI; forward problem; filtered back projection method; reciprocity theorem; MAGNETOACOUSTIC TOMOGRAPHY; LORENTZ FORCE;
D O I
10.1109/ACCESS.2019.2948731
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Magneto-Acousto-Electric Tomography with coil detection, known as Magneto-AcoustoElectric Tomography with Magnetic Induction (MAET-MI), is a non-contact resistivity-based imaging method that employs a coil to detect the induced current generated by the ultrasound in biological tissue, which lie under a static magnetic field. To reconstruct an image of the tissue's conductivity, we propose a reciprocal model to describe the relationship between the inducted voltage of a coil and its conductivity. Previous work on the reciprocal theorem demonstrates that reconstructing conductivity using this method is effective. The forward and inverse problem are usually not verified both numerically and experimentally. In this paper, different approaches are adopted to calculate the forward and the inverse problems for verification of the reciprocal model. This verifies that the reconstruction method based on electrode detection can be applied to MAET-MI. This means that the inverse problem of MAET-MI can be transformed into an inverse source reconstruction of a wave equation based on the coil detection. In the forward problem, the moment method is employed to calculate the Radon transform and generate the ultrasonic signals. For the inverse problem, the filtered back projection method is chosen to reconstruct the ultrasound sources, which are related to the curl of the current density in the reciprocal process. Based on the curl of the current density in the reciprocal process, four sets of correlation coefficients of the original and reconstructed images' model are all greater than 90%. The uniform error criterion is obtained via multiple reconstructions and comparison of multiple models. The reciprocal model exhibits a good uniformity and stability when describing the actual physical process. It also provides additional effective ideas for solving the inverse problem quickly to reconstruct the ultrasonic sources, which is corresponding to the actual distribution of the conductivity.
引用
收藏
页码:154076 / 154083
页数:8
相关论文
共 50 条
  • [41] Performance improvement of magneto-acousto-electrical tomography for biological tissues with sinusoid-Barker coded excitation
    Yu, Zheng-Feng
    Zhou, Yan
    Li, Yu-Zhi
    Ma, Qing-Yu
    Guo, Ge-Pu
    Tu, Juan
    Zhang, Dong
    CHINESE PHYSICS B, 2018, 27 (09)
  • [42] An Acoustic Characteristic Study of Magneto-Acousto-Electrical Tomography A new method to reconstruct current density distribution at every point of a sample
    Zeng, Xiaoping
    Liu, Guoqing
    Xia, Hui
    Xu, Xiaoyu
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 95 - 98
  • [43] Simulation of Lung Tissue Imaging Based on Magneto-Acousto-Electrical Technology
    Li C.
    Li Y.
    Liu G.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 (04): : 732 - 737
  • [44] Rapid rotational magneto-acousto-electrical tomography with filtered back-projection algorithm based on plane waves
    Sun, Tong
    Hao, Penghui
    Chin, Chien Ting
    Deng, Dingqian
    Chen, Tiemei
    Chen, Yi
    Chen, Mian
    Lin, Haoming
    Lu, Minhua
    Gao, Yi
    Chen, Siping
    Chang, Chunqi
    Chen, Xin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (09):
  • [45] A new magneto-acousto-electrical detection method for defects in high conductivity non-ferromagnetic materials
    Yan, Xiaoheng
    Xu, Chuwen
    Lv, Jingxiang
    Yang, Yanju
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (43)
  • [46] Noise reduction in Magneto-acousto-electrical NDT using analytic wavelet thresholding
    Lv Jingxiang
    Liu, Guoqiang
    2017 IEEE 3RD INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC), 2017, : 585 - 588
  • [47] Iterative Reconstruction Algorithms in Magneto-Acousto-Electrical Computed Tomography (MAE-CT) for Image Quality Improvement
    Sun, Tong
    Yu, Mengmeng
    Yu, Linguo
    Deng, Dingqian
    Chen, Mian
    Lin, Haoming
    Chen, Siping
    Chang, Chunqi
    Chen, Xin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (02) : 669 - 678
  • [48] Numerical Studies for Magneto-Acousto-Electrical Tomography with Magnetic Field Measurement Using Linear Frequency Modulated Excitation
    Gozu, Mehmet Soner
    Tetik, Ahmet Onder
    Gencer, Nevzat Guneri
    2022 MEDICAL TECHNOLOGIES CONGRESS (TIPTEKNO'22), 2022,
  • [49] Removing the Effect of the Transfer Function of a Coil with High Q factor on Signals of Magneto-Acousto-Electrical Tomograpy with Magnetic Field Measurement
    Tetik, Ahmet Onder
    Gozu, Mehmet Soner
    Gencer, Nevzat Guneri
    2022 MEDICAL TECHNOLOGIES CONGRESS (TIPTEKNO'22), 2022,
  • [50] A 2D Magneto-Acousto-Electrical Tomography Method to Detect Conductivity Variation Using Multifocus Image Method
    Dai, Ming
    Chen, Xin
    Sun, Tong
    Yu, Lingyao
    Chen, Mian
    Lin, Haoming
    Chen, Siping
    SENSORS, 2018, 18 (07)