Study on Reciprocal Models for Magneto-Acousto-Electrical Tomography With Coil Detection

被引:1
|
作者
Gong, Likun [1 ]
Yang, Lan [1 ]
Yang, Siyi [1 ]
Wang, Yuanze [1 ]
Zhong, Minjing [1 ]
Guo, Liang [2 ]
机构
[1] China Univ Petr, Coll Informat & Control Engn, Qingdao 266580, Peoples R China
[2] China Univ Petr, Coll Control Sci & Engn, Qingdao 266580, Peoples R China
关键词
MAET-MI; forward problem; filtered back projection method; reciprocity theorem; MAGNETOACOUSTIC TOMOGRAPHY; LORENTZ FORCE;
D O I
10.1109/ACCESS.2019.2948731
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Magneto-Acousto-Electric Tomography with coil detection, known as Magneto-AcoustoElectric Tomography with Magnetic Induction (MAET-MI), is a non-contact resistivity-based imaging method that employs a coil to detect the induced current generated by the ultrasound in biological tissue, which lie under a static magnetic field. To reconstruct an image of the tissue's conductivity, we propose a reciprocal model to describe the relationship between the inducted voltage of a coil and its conductivity. Previous work on the reciprocal theorem demonstrates that reconstructing conductivity using this method is effective. The forward and inverse problem are usually not verified both numerically and experimentally. In this paper, different approaches are adopted to calculate the forward and the inverse problems for verification of the reciprocal model. This verifies that the reconstruction method based on electrode detection can be applied to MAET-MI. This means that the inverse problem of MAET-MI can be transformed into an inverse source reconstruction of a wave equation based on the coil detection. In the forward problem, the moment method is employed to calculate the Radon transform and generate the ultrasonic signals. For the inverse problem, the filtered back projection method is chosen to reconstruct the ultrasound sources, which are related to the curl of the current density in the reciprocal process. Based on the curl of the current density in the reciprocal process, four sets of correlation coefficients of the original and reconstructed images' model are all greater than 90%. The uniform error criterion is obtained via multiple reconstructions and comparison of multiple models. The reciprocal model exhibits a good uniformity and stability when describing the actual physical process. It also provides additional effective ideas for solving the inverse problem quickly to reconstruct the ultrasonic sources, which is corresponding to the actual distribution of the conductivity.
引用
收藏
页码:154076 / 154083
页数:8
相关论文
共 50 条
  • [31] 2D magneto-acousto-electrical tomography system based on reciprocity theorem
    Xia, Hui
    Liu, Guoqiang
    Huang, Xin
    Chen, Jing
    Liu, G., 1600, China Machine Press (28): : 163 - 168
  • [32] Magneto-acousto-electrical Measurement Based Electrical Conductivity Reconstruction for Tissues
    Zhou, Yan
    Ma, Qingyu
    Guo, Gepu
    Tu, Juan
    Zhang, Dong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (05) : 1086 - 1094
  • [33] Effect of the secondary process on mass point vibration velocity propagation in magneto-acoustic tomography and magneto-acousto-electrical tomography
    Sun, Zhishen
    Liu, Guoqiang
    Guo, Liang
    Xia, Hui
    Wang, Xinli
    TECHNOLOGY AND HEALTH CARE, 2016, 24 : S683 - S689
  • [34] Noninvasive Treatment-Efficacy Evaluation for HIFU Therapy Based on Magneto-Acousto-Electrical Tomography
    Zhou, Yan
    Yu, Zhengfeng
    Ma, Qingyu
    Guo, Gepu
    Tu, Juan
    Zhang, Dong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (03) : 666 - 674
  • [35] Aluminum alloy defects testing using Magneto-acousto-electrical
    Lv, Jingxiang
    Liu, Guoqiang
    PROCEEDINGS OF 2018 IEEE 3RD ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC 2018), 2018, : 1371 - 1375
  • [36] Magneto-Acousto-Electrical Tomography with Magnetic Induction Based on Laser-Generated Ultrasound Transducer
    Xia, Hui
    Ding, Guangxin
    Liu, Guoqiang
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (01) : 183 - 187
  • [37] Numerical implementation of magneto-acousto-electrical tomography (MAET) using a linear phased array transducer
    Gozu, Mehmet Soner
    Zengin, Reyhan
    Gencer, Nevzat Guneri
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):
  • [38] Performance improvement of magneto-acousto-electrical tomography for biological tissues with sinusoid-Barker coded excitation
    余正风
    周䶮
    李禹志
    马青玉
    郭各朴
    屠娟
    章东
    Chinese Physics B, 2018, (09) : 350 - 357
  • [39] Optimization of multi-angle Magneto-Acousto-Electrical Tomography (MAET) based on a numerical method
    Sun, Tong
    Zeng, Xin
    Hao, Penghui
    Chin, Chien Ting
    Chen, Mian
    Yan, Jiejie
    Dai, Ming
    Lin, Haoming
    Chen, Siping
    Chen, Xin
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2020, 17 (04) : 2864 - 2880
  • [40] Conductivity reconstruction algorithms and numerical simulations for magneto-acousto-electrical tomography with piston transducer in scan mode
    Guo Liang
    Liu Guo-Qiang
    Xia Hui
    Liu Yu
    Lu Min-Hua
    CHINESE PHYSICS B, 2014, 23 (10)