Numerical implementation of magneto-acousto-electrical tomography (MAET) using a linear phased array transducer

被引:11
|
作者
Gozu, Mehmet Soner [1 ]
Zengin, Reyhan [1 ,2 ]
Gencer, Nevzat Guneri [1 ]
机构
[1] Middle East Tech Univ, Dept Elect & Elect Engn, Ankara, Turkey
[2] Selcuk Univ, Dept Elect & Elect Engn, Konya, Turkey
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 03期
关键词
Hall effect imaging; electrical conductivity imaging; ultrasound; linear phased array transducer; magneto-acousto-electrical tomography; INDUCED LORENTZ FORCE; DIELECTRIC-PROPERTIES; BIOLOGICAL TISSUES; MODELS;
D O I
10.1088/1361-6560/aa9f3b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, the performance and implementation of magneto-acousto-electrical tomography (MAET) is investigated using a linear phased array (LPA) transducer. The goal of MAET is to image the conductivity distribution in biological bodies. It uses the interaction between ultrasound and a static magnetic field to generate velocity current density distribution inside the body. The resultant voltage due to velocity current density is sensed by surface electrodes attached on the body. In this study, the theory of MAET is reviewed. A 16-element LPA transducer with 1 MHz excitation frequency is used to provide beam directivity and steerability of acoustic waves. Different two-dimensional numerical models of breast and tumour are formed to analyze the multiphysics problem coupled with acoustics and electromagnetic fields. In these models, velocity current density distributions are obtained for pulse type ultrasound excitations. The static magnetic field is assumed as 1 T. To sense the resultant voltage caused by the velocity current density, it is assumed that two electrodes are attached on the surface of the body. The performance of MAET is shown through sensitivity matrix analysis. The sensitivity matrix is obtained for two transducer positions with 13 steering angles between -30 degrees to 30 degrees with 5 degrees angular intervals. For the reconstruction of the images, truncated singular value decomposition method is used with different signal-to-noise ratio (SNR) values (20 dB, 40 dB, 60 dB and 80 dB). The resultant images show that the perturbation (5 mm x 5 mm) placed 35 mm depth can be detected even if the SNR is 20 dB.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Optimization of multi-angle Magneto-Acousto-Electrical Tomography (MAET) based on a numerical method
    Sun, Tong
    Zeng, Xin
    Hao, Penghui
    Chin, Chien Ting
    Chen, Mian
    Yan, Jiejie
    Dai, Ming
    Lin, Haoming
    Chen, Siping
    Chen, Xin
    [J]. MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2020, 17 (04) : 2864 - 2880
  • [2] Numerical Simulations and Experimental Study of Magneto-Acousto-Electrical Tomography With Plane Transducer
    Li, Yuanyuan
    Liu, Guoqiang
    Xia, Hui
    Xia, Zhengwu
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (03)
  • [3] Conductivity reconstruction algorithms and numerical simulations for magneto-acousto-electrical tomography with piston transducer in scan mode
    Guo Liang
    Liu Guo-Qiang
    Xia Hui
    Liu Yu
    Lu Min-Hua
    [J]. CHINESE PHYSICS B, 2014, 23 (10)
  • [4] Numerical Studies for Magneto-Acousto-Electrical Tomography with Magnetic Field Measurement Using Linear Frequency Modulated Excitation
    Gozu, Mehmet Soner
    Tetik, Ahmet Onder
    Gencer, Nevzat Guneri
    [J]. 2022 MEDICAL TECHNOLOGIES CONGRESS (TIPTEKNO'22), 2022,
  • [5] A method of the forward problem for magneto-acousto-electrical tomography
    Lv, Jingxiang
    Liu, Guoqiang
    Wang, Xinli
    Xia, Hui
    [J]. TECHNOLOGY AND HEALTH CARE, 2016, 24 : S733 - S738
  • [6] Magneto-Acousto-Electrical Tomography with Magnetic Induction Based on Laser-Generated Ultrasound Transducer
    Xia, Hui
    Ding, Guangxin
    Liu, Guoqiang
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (01) : 183 - 187
  • [7] Three-dimensional magneto-acousto-electrical tomography (3D MAET) with single-element ultrasound transducer and coded excitation: A phantom validation study
    Sun, Tong
    Yu, Linguo
    Deng, Dingqian
    Yu, Mengmeng
    Chen, Yi
    Chang, Chunqi
    Chen, Mian
    Chen, Siping
    Chen, Xin
    Lin, Haoming
    [J]. NEUROCOMPUTING, 2023, 536 : 80 - 89
  • [8] Simulation of Magneto-Acousto-Electrical Tomography Based on Approximately Realistic Numerical Breast Model
    Zhang, Wenwei
    Liu, Guoqiang
    Xia, Hui
    Li, Yuanyuan
    Li, Shiqiang
    Li, Xiaonan
    [J]. PROCEEDINGS OF 2023 INTERNATIONAL CONFERENCE ON WIRELESS POWER TRANSFER, VOL 1, ICWPT 2023, 2024, 1158 : 706 - 713
  • [9] Magneto-acousto-electrical tomography using nonlinearly frequency-modulated ultrasound
    Cheng, Zhizhuo
    Sun, Zhishen
    Wang, Jianfei
    Jia, Kebin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (08):
  • [10] Research on Pneumothorax Detection Based on Magneto-Acousto-Electrical Tomography
    Li, Cailian
    Li, Yuanyuan
    Liu, Guoqiang
    [J]. Progress In Electromagnetics Research M, 2021, 106 : 71 - 82