Determination of Nitrite and Nitrate in Freshwaters using Flow Injection Luminol Chemiluminescence Detection

被引:0
|
作者
Attiq-ur-Rehman [1 ]
Yaqoob, Mohammad [1 ]
Waseem, Amir [2 ]
Nabi, Abdul [1 ]
机构
[1] Univ Balochistan, Dept Chem, Quetta 87300, Pakistan
[2] COMSATS Inst Informat Technol, Dept Chem, Abbottabad 22060, Pakistan
关键词
Flow injection analysis; chemiluminescence; nitrite; nitrate; freshwaters; SPECTROPHOTOMETRIC METHOD; NANOMOLAR CONCENTRATIONS; PHOTODEGRADATION; REDUCTION; AMMONIA;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A flow injection method for determination of nitrite and nitrate in freshwaters is described based on luminol-hypochlorite chemiluminescence (CL) system. Nitrate is reduced on-line with a cadmium reduction column to nitrite and its inhibition effect on luminol CL emission was measured. The effects of chemical and physical parameters such as buffer pH and concentration, luminol, sodium hypochlorite and sulfuric acid concentrations, flow rate, and sample volume were investigated. The calibration graphs were linear over the range 0.1-50 mu M (R-2 = 0.9989 and 0.9984) for nitrite and nitrate respectively with a limit of detection (S/N = 3) of 4.0 x 10(-8) M and a sample throughput of 120 samples per hour. The effect of foreign ions was studied and the method was successfully applied to the determination of nitrite and nitrate in water samples. The results obtained were in good agreement with those achieved by a spectrophotometric reference method at the 95% confidence level. Standard addition method was also applied to the freshwater samples and the recovery values were found in the range of 92-109% and 94-105% for nitrite and nitrate respectively.
引用
收藏
页码:569 / 575
页数:7
相关论文
共 50 条
  • [21] Determination of subnanomolar concentrations of vanadium in environmental water samples using flow injection with luminol chemiluminescence detection
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    LUMINESCENCE, 2011, 26 (06) : 403 - 409
  • [22] Determination of epinephrine by flow-injection analysis using luminol-hexacyanoferrate(III) chemiluminescence detection
    Kojlo, A
    Nalewajko, E
    CHEMIA ANALITYCZNA, 2004, 49 (05): : 653 - 663
  • [23] Flow Injection Chemiluminescence Determination of Paraquat using Luminol and Ag(III) Complex
    Liu, Fei
    Shi, Hongmei
    Xu, Xiangdong
    Kang, Weijun
    Li, Zhanhua
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (02) : 795 - 798
  • [24] Simultaneous determination of nitrite and nitrate in various samples using flow injection with spectrophotometric detection
    Ensafi, AA
    Kazemzadeh, A
    ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) : 15 - 21
  • [25] A chemiluminescence flow injection system for nitrite ion determination
    M. K. Amini
    M. Pourhossein
    M. Talebi
    Journal of the Iranian Chemical Society, 2005, 2 : 305 - 314
  • [26] A chemiluminescence flow injection system for nitrite ion determination
    Amini, M. K.
    Pourhossein, M.
    Talebi, M.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2005, 2 (04) : 305 - 314
  • [27] Flow injection biamperometric determination of nitrite and nitrate
    Danet, AF
    David, V
    ANALYTICAL LETTERS, 1998, 31 (05) : 751 - 764
  • [28] Determination of methyltestosterone using flow injection with chemiluminescence detection
    Xie, ZH
    Ouyang, XQ
    Guo, LQ
    Lin, XC
    Chen, GN
    LUMINESCENCE, 2005, 20 (03) : 231 - 235
  • [30] SIMULTANEOUS FLOW-INJECTION DETERMINATION OF NITRATE AND NITRITE IN WATER BY GAS-PHASE CHEMILUMINESCENCE
    AOKI, T
    WAKABAYASHI, M
    ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 308 - 312