A chemiluminescence flow injection system for nitrite ion determination

被引:0
|
作者
M. K. Amini
M. Pourhossein
M. Talebi
机构
[1] University of Isfahan,Chemistry Department
关键词
Chemiluminescence; Liquid-gas separator; Nitrite; Nitric oxide; Water analysis; Ozone generator;
D O I
暂无
中图分类号
学科分类号
摘要
A chemiluminescence system is described for the determination of nitrite ion based on new designs for an ozone generator, liquid-gas separator and chemiluminescence reaction cell. The method is based on the gas-phase chemiluminescence reaction between ozone and nitric oxide, which is generated from the reduction of nitrite with iodide in sulfuric acid solution. The efficiency of the system was evaluated by investigation of the analytical performance characteristics of the system for nitrite determination in batch and flow injection procedures. Under optimal conditions, the chemiluminescence response of the system was linear against the nitrite concentration over the range 1 to 1 × 104 ng ml−1 in the batch procedure and 10 to 5 × 103 ng ml−1 in the flow injection procedure, with detection limits of 1 and 10 ng ml−1, respectively. The method is highly selective and allows for the determination of nitrite in the presence of high concentrations of several cationic, anionic and nitrogen containing species. It has been successfully applied to the analysis of nitrite in natural water and soil extracts.
引用
收藏
页码:305 / 314
页数:9
相关论文
共 50 条
  • [1] A chemiluminescence flow injection system for nitrite ion determination
    Amini, M. K.
    Pourhossein, M.
    Talebi, M.
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2005, 2 (04) : 305 - 314
  • [2] Determination of nitrite by inhibition of the chemiluminescence of acriflavine in a flow-injection assembly
    Icardo, MC
    Mateo, JVG
    Calatayud, JM
    [J]. ANALYST, 2001, 126 (08) : 1423 - 1427
  • [3] A flow injection chemiluminescence system for the determination of isoniazid
    Huang, YM
    Zhang, ZJ
    Zhang, DJ
    Lv, J
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04): : 429 - 431
  • [4] A flow injection chemiluminescence system for the determination of isoniazid
    Y. Huang
    Z. Zhang
    D. Zhang
    J. Lv
    [J]. Fresenius' Journal of Analytical Chemistry, 2000, 368 : 429 - 431
  • [5] Chemiluminescence microflow injection analysis system on a chip for the determination of nitrite in food
    He, Deyong
    Zhang, Zhujun
    Huang, Ying
    Hu, Yufei
    [J]. FOOD CHEMISTRY, 2007, 101 (02) : 667 - 672
  • [6] Chemiluminescence flow system for the determination of ammonium ion
    Qin, W
    Zhang, ZJ
    Li, BX
    Peng, YY
    [J]. TALANTA, 1999, 48 (01) : 225 - 229
  • [7] Determination of Nitrite and Nitrate in Freshwaters using Flow Injection Luminol Chemiluminescence Detection
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    [J]. ACTA CHIMICA SLOVENICA, 2011, 58 (03) : 569 - 575
  • [8] Determination of trivalent terbium ion in mineral by flow injection chemiluminescence
    Wang, XL
    Zhao, HC
    Li, X
    Chen, S
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (05) : 647 - 649
  • [9] A Novel Flow Injection Chemiluminescence System for the Determination of Reserpine
    庄惠生
    王琼娥
    魏巧华
    吴言林
    [J]. Journal of Donghua University(English Edition), 2004, (06) : 7 - 9
  • [10] Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection
    Yaqoob, Mohammad
    Biot, Beatriz Folgado
    Nabi, Abdul
    Worsfold, Paul J.
    [J]. LUMINESCENCE, 2012, 27 (05) : 419 - 425