A novel flow-injection method for the determination of epinephrine in pharmaceutical preparations has been proposed. Detection of the drug is based on the enhancement of chemiluminescence of the luminol-potassium hexacyanoferrate(III) system by epinephrine in the alkaline medium. Linear calibration plot is observed for epinephrine concentration ranging from 20-260 mug L-1. The detection limit was 12 mug L-1 and the relative standard deviation was 0.9% for 140 mug L-1 epinephrine (n = 22). The sampling throughput of 160 samples h(-1) was achieved. The proposed method has been successfully applied to the determination of epinephrine in pharmaceutical injections.
引用
收藏
页码:653 / 663
页数:11
相关论文
共 50 条
  • [1] Determination of dopamine by flow-injection analysis coupled with luminol-hexacyanoferrate(III) chemiluminescence detection
    Nalewajko, E
    Ramírez, RB
    Kojlo, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (01) : 219 - 223
  • [2] Flow-injection electrogenerated chemiluminescence determination of epinephrine using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    ANALYTICA CHIMICA ACTA, 2001, 441 (01) : 81 - 86
  • [3] Determination of α,4-dihydroxy-3-methoxybenzeneacetic acid (vanilmandelic acid) by flow injection analysis coupled with luminol-hexacyanoferrate(III) chemiluminescence detection
    Barnett, NW
    Francis, PS
    Lewis, SW
    Lim, KF
    ANALYTICAL COMMUNICATIONS, 1999, 36 (04): : 131 - 134
  • [4] Determination of Epinephrine by Flow Injection Analysis Coupled Ag(III) Complex-Luminol Chemiluminescence Detection
    Bai Jiangbo
    Shi Hongmei
    Zhang Yingze
    Tian Dehu
    Xu Xiangdong
    Kang Weijun
    CHINESE JOURNAL OF CHEMISTRY, 2009, 27 (04) : 745 - 750
  • [5] Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection
    Yaqoob, Mohammad
    Biot, Beatriz Folgado
    Nabi, Abdul
    Worsfold, Paul J.
    LUMINESCENCE, 2012, 27 (05) : 419 - 425
  • [6] Cetyltrimethylammonium Bromide-Enhanced Chemiluminescence Determination of Uric Acid Using a Luminol-Hexacyanoferrate(III)-Hexacyanoferrate(II) System
    Suqin Han
    Erbao Liu
    Hua Li
    Analytical Sciences, 2005, 21 : 111 - 114
  • [7] Cetyltrimethylammonium bromide-enhanced chemiluminescence determination of uric acid using a luminol-hexacyanoferrate(III)-hexacyanoferrate(II) system
    Han, SQ
    Liu, EB
    Li, H
    ANALYTICAL SCIENCES, 2005, 21 (02) : 111 - 114
  • [8] Flow-injection electrogenerated chemiluminescence determination of isoniazid using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    ANALYTICAL SCIENCES, 2001, 17 (09) : 1095 - 1099
  • [9] Flow-Injection Electrogenerated Chemiluminescence Determination of Isoniazid Using Luminol
    Xingwang Zheng
    Zhihui Guo
    Zhujun Zhang
    Analytical Sciences, 2001, 17 : 1095 - 1099
  • [10] Photodegradation and flow-injection determination of simetryn herbicide by luminol chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL SCIENCES, 2008, 24 (08) : 979 - 983