Orthopaedic and non-orthopaedic applications of a single-energy iterative metal artefact reduction technique and other metal artefact reduction techniques explained

被引:2
|
作者
Khor, Robert [1 ]
Buchan, Kevin [2 ]
Kuganesan, Ahilan [1 ]
Ardley, Nicholas [1 ]
Lau, Kenneth K. [3 ]
机构
[1] Monash Hlth, Monash Med Ctr, Dept Diagnost Imaging, Melbourne, Vic, Australia
[2] Philips Healthcare, CT Clin Sci, Macquarie Pk, NSW, Australia
[3] Monash Univ, Fac Med Nursing & Hlth Sci, Clayton, Vic, Australia
来源
BRITISH JOURNAL OF RADIOLOGY | 2016年 / 89卷 / 1064期
关键词
COMPUTED-TOMOGRAPHY; UNITED-STATES; CT; ALGORITHM; MRI; HIP;
D O I
10.1259/bjr.20160171
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Metal within the CT field of view causes artefact that degrades the diagnostic quality of the processed images. This is related to the high atomic number of most metals and is due to a combination of beam hardening, scatter, edge effects and photon starvation. Both software and hardware metal artefact reduction (MAR) techniques have been developed. Iterative reconstruction software MAR techniques can be applied on raw CT data sets and show improved image quality in the setting of sparse projection data when compared with filtered back-projection methods. Recently, a novel single-energy iterative metal artefact reduction technique (IMART) was released for use with large orthopaedic devices. The aim of this pictorial essay was to demonstrate the usefulness of IMART in the setting of both orthopaedic and non-orthopaedic metallic objects and devices.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Metal artefact reduction from dental hardware in carotid CT angiography using iterative reconstructions
    Morsbach, Fabian
    Wurnig, Moritz
    Kunz, Daniel M.
    Krauss, Andreas
    Schmidt, Bernhard
    Kollias, Spyros S.
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2013, 23 (10) : 2687 - 2694
  • [22] Evaluation of efficacy of metal artefact reduction technique using contrast media in Computed Tomography
    Yusob, Diana
    Zukhi, Jihan
    Tajuddin, Abd Aziz
    Zainon, Rafidah
    10TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS & 1ST AMDI INTERNATIONAL ONCOLOGY SYMPOSIUM, 2017, 851
  • [23] Comparison and Combination of Dual-Energy- and Iterative-Based Metal Artefact Reduction on Hip Prosthesis and Dental Implants
    Bongers, Malte N.
    Schabel, Christoph
    Thomas, Christoph
    Raupach, Rainer
    Notohamiprodjo, Mike
    Nikolaou, Konstantin
    Bamberg, Fabian
    PLOS ONE, 2015, 10 (11):
  • [24] Metal Artifact Reduction on Chest Computed Tomography Examinations: Comparison of the Iterative Metallic Artefact Reduction Algorithm and the Monoenergetic Approach
    Pagniez, Julien
    Legrand, Louise
    Khung, Suonita
    Faivre, Jean-Baptiste
    Duhamel, Alain
    Krauss, Andreas
    Remy, Jacques
    Remy-Jardin, Martine
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (03) : 446 - 454
  • [25] Combined Dual-Energy and Single-Energy Metal Artifact Reduction Techniques Versus Single-Energy Techniques Alone for Lesion Detection Near an Arthroplasty
    Chandrasekar, Suraj
    Colak, Ceylan
    Obuchowski, Nancy A.
    Primak, Andrew N.
    Karim, Wadih
    Subhas, Naveen
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 425 - 432
  • [26] Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms
    Aissa, Joel
    Boos, Johannes
    Sawicki, Lino Morris
    Heinzler, Niklas
    Krzymyk, Karl
    Sedlmair, Martin
    Kroepil, Patric
    Antoch, Gerald
    Thomas, Christoph
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1079):
  • [27] Combined application of single-energy metal artifact reduction and reconstruction techniques in patients with Cochlear implants
    Wei, Fanqin
    Li, Jiahui
    Zhou, Chunxiang
    Li, Yun
    Wang, Xianren
    Huang, Bixue
    Sun, Qiyang
    Xiong, Guanxia
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2020, 49 (01)
  • [28] Combined application of single-energy metal artifact reduction and reconstruction techniques in patients with Cochlear implants
    Fanqin Wei
    Jiahui Li
    Chunxiang Zhou
    Yun Li
    Xianren Wang
    Bixue Huang
    Qiyang Sun
    Guanxia Xiong
    Journal of Otolaryngology - Head & Neck Surgery, 49
  • [29] Impact of dual energy cardiac CT for metal artefact reduction post aortic valve replacement
    Schwartz, Fides Regina
    Tailor, Tina
    Gaca, Jeffrey G.
    Kiefer, Todd
    Harrison, Kevin
    Hughes, G. Chad
    Ramirez-Giraldo, Juan-Carlos
    Marin, Daniele
    Hurwitz, Lynne M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129
  • [30] Structure delineation in the presence of metal - A comparative phantom study using single and dual-energy computed tomography with and without metal artefact reduction
    Pettersson, Erik
    Back, Anna
    Bjork-Eriksson, Thomas
    Lindencrona, Ulrika
    Petruson, Karin
    Thilander-Klang, Anne
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 9 : 43 - 49