Comparison and Combination of Dual-Energy- and Iterative-Based Metal Artefact Reduction on Hip Prosthesis and Dental Implants

被引:78
|
作者
Bongers, Malte N. [1 ]
Schabel, Christoph [1 ]
Thomas, Christoph [2 ]
Raupach, Rainer [3 ]
Notohamiprodjo, Mike [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
机构
[1] Univ Hosp Tubingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[2] Univ Hosp Dusseldorf, Dept Diagnost & Intervent Radiol, D-40225 Dusseldorf, Germany
[3] Siemens AG, Healthcare Sect, D-91301 Forchheim, Germany
来源
PLOS ONE | 2015年 / 10卷 / 11期
关键词
COMPUTED-TOMOGRAPHY; ORTHOPEDIC IMPLANTS; CT; RECONSTRUCTIONS; IMAGES;
D O I
10.1371/journal.pone.0143584
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To compare and combine dual-energy based and iterative metal artefact reduction on hip prosthesis and dental implants in CT. Material and Methods A total of 46 patients (women: 50%, mean age: 63+/-15years) with dental implants or hip prostheses (n = 30/20) were included and examined with a second-generation Dual Source Scanner. 120kV equivalent mixed-images were derived from reconstructions of the 100/Sn140kV source images using no metal artefact reduction (NOMAR) and iterative metal artefact reduction (IMAR). We then generated monoenergetic extrapolations at 130keV from source images without IMAR (DEMAR) or from source images with IMAR, (IMAR + DEMAR). The degree of metal artefact was quantified for NOMAR, IMAR, DEMAR and IMAR+DEMAR using a Fourier-based method and subjectively rated on a five point Likert scale by two independent readers. Results In subjects with hip prosthesis, DEMAR and IMAR resulted in significantly reduced artefacts compared to standard reconstructions (33% vs. 56%; for DEMAR and IMAR; respectively, p<0.005), but the degree of artefact reduction was significantly higher for IMAR (all p<0.005). In contrast, in subjects with dental implants only IMAR showed a significant reduction of artefacts whereas DEMAR did not (71%, vs. 8% p<0.01 and p = 0.1; respectively). Furthermore, the combination of IMAR with DEMAR resulted in additionally reduced artefacts (Hip prosthesis: 47%, dental implants 18%; both p<0.0001). Conclusion IMAR allows for significantly higher reduction of metal artefacts caused by hip prostheses and dental implants, compared to a dual energy based method. The combination of DE-source images with IMAR and subsequent monoenergetic extrapolation provides an incremental benefit compared to both single methods.
引用
收藏
页数:12
相关论文
共 33 条
  • [1] Evaluation of dual energy CT and iterative metal artefact reduction (iMAR) for artefact reduction in radiation therapy
    P. Lim
    J. Barber
    J. Sykes
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 1025 - 1032
  • [2] Evaluation of dual energy CT and iterative metal artefact reduction (iMAR) for artefact reduction in radiation therapy
    Lim, P.
    Barber, J.
    Sykes, J.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 1025 - 1032
  • [3] Dual energy CT and iterative metal artefact reduction for accurate tumour delineation
    Kovacs, D.
    Rechner, L.
    Bangsgaard, J.
    Berthelsen, A.
    Costa, J.
    Friborg, J.
    Persson, G.
    Specht, L.
    Vogelius, I.
    Aznar, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S70 - S70
  • [4] Computed Tomography Imaging of a Hip Prosthesis Using Iterative Model-Based Reconstruction and Orthopaedic Metal Artefact Reduction: A Quantitative Analysis
    Wellenberg, Ruud H. H.
    Boomsma, Martijn F.
    van Osch, Jochen A. C., Jr.
    Vlassenbroek, Alain
    Milles, Julien
    Edens, Mireille A.
    Streekstra, Geert J.
    Slump, Cornelis H.
    Maas, Mario
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 971 - 978
  • [5] Combined dual energy and iterative metal artefact reduction for PET/CT in head and neck cancer
    Kovacs, D. G.
    Ladefoged, C. N.
    Berthelsen, A. K.
    Fischer, B. M.
    Andersen, F. L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [6] Combined dual energy and iterative metal artefact reduction for PET/CT in head and neck cancer
    Kovacs, D.G.
    Ladefoged, C.N.
    Berthelsen, A.K.
    Fischer, B.M.
    Andersen, F.L.
    Kovacs, D.G. (david.gergely.kovacs@regionh.dk), 1600, IOP Publishing Ltd (65):
  • [7] Comparison of dual-energy computed tomography (DECT) polychromatic and monochromatic images with and without iterative metal artifact reduction algorithm in patients with dental implants
    Huang, Shiqi
    Liang, Yuhong
    Yao, Xinqun
    Qin, Xiangyun
    He, Changguang
    Luo, Li'an
    Huang, Lveqin
    Lv, Yaping
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (07) : 4688 - 4702
  • [8] Visibility of bony structures around hip prostheses in dual-energy CT: With or without metal artefact reduction software
    Jeong, Jewon
    Kim, Hyun-joo
    Oh, Eunsun
    Cha, Jang Gyu
    Hwang, Jiyoung
    Hong, Seong Sook
    Chang, Yun Woo
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2018, 62 (05) : 634 - 641
  • [9] Quantitative Effect of Metal Artefact Reduction on CT-based attenuation correction in FDG PET/CT in patients with hip prosthesis
    Maarten Haemels
    Delphine Vandendriessche
    Jeroen De Geeter
    James Velghe
    Maxence Vandekerckhove
    Frank De Geeter
    EJNMMI Physics, 8
  • [10] Quantitative Effect of Metal Artefact Reduction on CT-based attenuation correction in FDG PET/CT in patients with hip prosthesis
    Haemels, Maarten
    Vandendriessche, Delphine
    De Geeter, Jeroen
    Velghe, James
    Vandekerckhove, Maxence
    De Geeter, Frank
    EJNMMI PHYSICS, 2021, 8 (01)