Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CT

被引:53
|
作者
Zammit-Maempel, I [1 ]
Chadwick, CL [1 ]
Willis, SP [1 ]
机构
[1] Newcastle Gen Hosp, Newcastle Upon Tyne NE4 6BE, Tyne & Wear, England
来源
BRITISH JOURNAL OF RADIOLOGY | 2003年 / 76卷 / 906期
关键词
D O I
10.1259/bjr/82798696
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
CT has become an established examination in the evaluation of the paranasal sinuses. Until recently this was achieved by the direct coronal technique on conventional and single slice helical scanners. With the advent of multislice technology, thin slice axial CT with excellent coronal and sagittal reconstructions is now the norm. We describe a study designed to evaluate the radiation dose to the lens of the eye and thyroid gland in the axial and coronal planes on a Siemens Volume Zoom quad slice scanner at 140 kV and effective mAs of 100 using 1 mm collimation. Thermoluminescent dosimeters were placed on the eyelid and thyroid gland of 29 patients scanned axially in the supine position and a further 28 patients scanned coronally in the prone position with gantry tilt. The results show mean doses of 35.1 mGy (lens) and 2.9 mGy (thyroid gland) in the coronal plane compared with 24.5 mGy (lens) and 1.4 mGy (thyroid gland) in the axial plane. Results obtained from a head phantom and from using the ImPACT CT dose calculator were comparable. The kV and mAs were then reduced to 120 and 40, respectively, and the axial study repeated using the head phantom and predicted doses using the ImPACT CT dose calculator. The low dose scanning technique revealed a lens dose of 9.2 mGy and thyroid dose of 0.4 mGy. The eye dose on a multislice scanner is still substantially less than the threshold dose of 0.5-2 Gy for detectable lens opacities. These results indicate that, in addition to the established perceived advantages of multislice axial sinus CT, i.e. patient comfort, no artefact from dental amalgam and reproducible true coronal images, should be included a decreased radiation dose to both the eye lens and thyroid gland compared with direct coronal scanning.
引用
收藏
页码:418 / 420
页数:3
相关论文
共 50 条
  • [21] Doses in eye lens, thyroid, and gonads, due to scattered radiation, during a CT radiodiagnosis study
    Vazquez-Banuelos, Joel
    Eduardo Campillo-Rivera, Guillermo
    Garcia-Duran, Angel
    Reyes Rivera, Eric
    Vasquez Arteaga, Marcial
    Baltazar Raigosa, Antonio
    Rene Veg-Carrillo, Hector
    [J]. APPLIED RADIATION AND ISOTOPES, 2019, 147 : 31 - 34
  • [22] Mean glandular dose in the mammary gland and dose of radiation in the thyroid gland and lens in women with and without breast implants during different modalities of mammography
    Perez Fuentes, J. A.
    Roldan Sanchez, V. S.
    Gordillo Ledesma, A. K.
    Mena, A. F.
    Brito, S.
    Soteldo, C.
    [J]. RADIOLOGIA, 2022, 64 : S11 - S19
  • [23] Evaluation of the Image Quality of Ultra-Low-Dose Paranasal Sinus CT
    Aksamoglu, Melih
    Menzilcioglu, Mehmet Sait
    [J]. EUROPEAN JOURNAL OF THERAPEUTICS, 2023, 29 (02): : 143 - 148
  • [24] Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT
    Kaatsch, Hanns Leonhard
    Fulisch, Florian
    Dillinger, Daniel
    Kubitscheck, Laura
    Becker, Benjamin V.
    Piechotka, Joel
    Brockmann, Marc A.
    Froelich, Matthias F.
    Schoenberg, Stefan O.
    Overhoff, Daniel
    Waldeck, Stephan
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (01) : 103 - 108
  • [25] Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT
    Kaatsch, Hanns Leonhard
    Fulisch, Florian
    Dillinger, Daniel
    Kubitscheck, Laura
    Becker, Benjamin, V
    Piechotka, Joel
    Brockmann, Marc A.
    Froelich, Matthias F.
    Schoenberg, Stefan O.
    Overhoff, Daniel
    Waldeck, Stephan
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (02) : 103 - 108
  • [26] Application Of organ dose modulation technique in CT scanning Of children paranasal sinus
    Zhuang, Xunhui
    Song, Xiufeng
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 127 : 57 - 58
  • [27] Occupational radiation dose to the lens of the eye of medical staff who assist in diagnostic CT scans
    Nagamoto, Keisuke
    Moritake, Takashi
    Nakagami, Koichi
    Morota, Koichi
    Matsuzaki, Satoru
    Nihei, Shun-ichi
    Kamochi, Masayuki
    Kunugita, Naoki
    [J]. HELIYON, 2021, 7 (01)
  • [28] IRRADIATION DOSE TO THE LENS OF THE EYE DURING CT OF THE HEAD
    LUND, E
    HALABURT, H
    [J]. NEURORADIOLOGY, 1982, 22 (04) : 181 - 184
  • [29] ESTIMATED FETAL RADIATION-DOSE FROM MULTISLICE CT STUDIES
    FELMLEE, JP
    GRAY, JE
    LEETZOW, ML
    PRICE, JC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (01) : 185 - 190
  • [30] Radiation dose in coronary multislice CT: A comparison with conventional diagnostic angiography
    Coles, DR
    Smail, M
    Negus, I
    Wilde, P
    Oberhoff, M
    Karsch, KR
    Baumbach, A