Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT

被引:0
|
作者
Kaatsch, Hanns Leonhard [1 ]
Fulisch, Florian [1 ]
Dillinger, Daniel [2 ]
Kubitscheck, Laura [1 ,3 ]
Becker, Benjamin, V [1 ,4 ]
Piechotka, Joel [1 ]
Brockmann, Marc A. [4 ]
Froelich, Matthias F. [5 ]
Schoenberg, Stefan O. [5 ]
Overhoff, Daniel [1 ,5 ]
Waldeck, Stephan [1 ,4 ]
机构
[1] Bundeswehr Cent Hosp Koblenz, Dept Radiol & Neuroradiol, R?ubenacher Str 170, D-56072 Koblenz, Germany
[2] Bundeswehr Cent Hosp, Dept Vasc Surg & Endovasc Surg, D-56072 Koblenz, Germany
[3] Ulm Univ, Bundeswehr Inst Radiobiol, D-80937 Munich, Germany
[4] Univ Med Ctr Mainz, Dept Neuroradiol, D-55131 Mainz, Germany
[5] Univ Med Ctr Mannheim, Dept Radiol & Nucl Med, Mannheim, Germany
关键词
photon-counting computed tomography; cone-beam computed tomography; paranasal sinus imaging; radiation dose; image quality; COMPUTED-TOMOGRAPHY; REDUCTION; PHANTOM; REGION; HEAD; CBCT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy. Methods: This single-centre retrospective study included 100 patients, who underwent either clinically indicated PCCT or CBCT of the paranasal sinus. Two blinded experienced ENT radiologists graded image quality and delineation of specific anatomical structures on a 5-point Likert scale. In addition, contrast-to-noise ratio (CNR) and applied radiation doses were compared among both techniques. Results: Image quality and delineation of bone structures in paranasal sinus PCCT was subjectively rated superior by both readers compared to CBCT (P < .001). CNR was significantly higher for photon-counting CT (P < .001). Mean effective dose for PCCT examinations was significantly lower than for CBCT (0.038 mSv +/- 0.009 vs. 0.14 mSv +/- 0.011; P < .001). Conclusion: In a performance comparison of PCCT and a modern CBCT scanner in paranasal sinus imaging, we demonstrated that first-use PCCT in clinical routine provides higher subjective image quality accompanied by higher CNR at close to a quarter of the dose exposure compared to CBCT.
引用
下载
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [1] Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT
    Kaatsch, Hanns Leonhard
    Fulisch, Florian
    Dillinger, Daniel
    Kubitscheck, Laura
    Becker, Benjamin V.
    Piechotka, Joel
    Brockmann, Marc A.
    Froelich, Matthias F.
    Schoenberg, Stefan O.
    Overhoff, Daniel
    Waldeck, Stephan
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (01) : 103 - 108
  • [2] Evaluation of the Image Quality of Ultra-Low-Dose Paranasal Sinus CT
    Aksamoglu, Melih
    Menzilcioglu, Mehmet Sait
    EUROPEAN JOURNAL OF THERAPEUTICS, 2023, 29 (02): : 143 - 148
  • [3] Ultra-Low-Dose Photon-Counting CT Imaging of the Paranasal Sinus With Tin Prefiltration How Low Can We Go?
    Grunz, Jan-Peter
    Petritsch, Bernhard
    Luetkens, Karsten Sebastian
    Kunz, Andreas Steven
    Lennartz, Simon
    Ergun, Suleyman
    Bley, Thorsten Alexander
    Huflage, Henner
    INVESTIGATIVE RADIOLOGY, 2022, 57 (11) : 728 - 733
  • [4] Ultra-low-dose cone-beam CT compared to standard dose in the assessment for acute fractures
    M. C. Murphy
    B. Gibney
    J. Walsh
    G. Orpen
    E. Kenny
    F. Bolster
    P. J. MacMahon
    Skeletal Radiology, 2022, 51 : 153 - 159
  • [5] Ultra-low-dose cone-beam CT compared to standard dose in the assessment for acute fractures
    Murphy, M. C.
    Gibney, B.
    Walsh, J.
    Orpen, G.
    Kenny, E.
    Bolster, F.
    MacMahon, P. J.
    SKELETAL RADIOLOGY, 2022, 51 (01) : 153 - 159
  • [6] Potential of Unenhanced Ultra-Low-Dose Abdominal Photon-Counting CT with Tin Filtration: A Cadaveric Study
    Huflage, Henner
    Grunz, Jan-Peter
    Patzer, Theresa Sophie
    Pannenbecker, Pauline
    Feldle, Philipp
    Sauer, Stephanie Tina
    Petritsch, Bernhard
    Erguen, Sueleyman
    Bley, Thorsten Alexander
    Kunz, Andreas Steven
    DIAGNOSTICS, 2023, 13 (04)
  • [7] Image Quality and Dose Measurement for Partial Cone-Beam CT
    Abouei, E.
    Ford, N.
    MEDICAL PHYSICS, 2014, 41 (06) : 143 - 143
  • [8] Deep learning-based enhancement of ultra-low-dose cone-beam CT image using simulated data
    Kim, Sunjung
    Lee, Hyunwoo
    Yi, Won-Jin
    Cho, Min Kook
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [9] Low-Dose High-Resolution Photon-Counting CT of the Lung: Radiation Dose and Image Quality in the Clinical Routine
    Woeltjen, Matthias Michael
    Niehoff, Julius Henning
    Michael, Arwed Elias
    Horstmeier, Sebastian
    Moenninghoff, Christoph
    Borggrefe, Jan
    Kroeger, Jan Robert
    DIAGNOSTICS, 2022, 12 (06)
  • [10] Patient dose and image quality of a cone-beam CT system for SPECT/CT: comparison with 16 slice CT
    Vandevoorde, C.
    Vandendriessche, D.
    D'Asseler, Y.
    Lambert, B.
    Goethals, I.
    Bacher, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S222 - S222