Mean glandular dose in the mammary gland and dose of radiation in the thyroid gland and lens in women with and without breast implants during different modalities of mammography

被引:0
|
作者
Perez Fuentes, J. A. [1 ]
Roldan Sanchez, V. S. [2 ]
Gordillo Ledesma, A. K. [1 ]
Mena, A. F. [1 ]
Brito, S. [1 ]
Soteldo, C. [2 ]
机构
[1] Ctr Clin Estereotaxia CECLINES, Caracas, Venezuela
[2] Inst Venezolano Invest Cient, Edo, Miranda, Venezuela
来源
RADIOLOGIA | 2022年 / 64卷
关键词
Radiation dose; Thyroid; Lens; Mean glandular dose; Mammography; Breast implant; TOMOSYNTHESIS;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
There have always been concerns about the secondary effects of diagnostic methods that use ionizing radiation. During mammography, the parameters to be concerned about are the mean glandular dose and the scatter dose. We evaluated the dose of radiation to the breast, thyroid gland, and lens in digital mammography in women with and without implants, in tomosynthesis in women with and without implants, and in contrast-enhanced mammography. Materials and methods: The study included 212 women with and without disease who were attended at the Centro Clinico de Estereotaxia, CECLINES, in Caracas, Venezuela, between June 2017 and August 2017; the women were classified into five groups according to the mammographic modality used to evaluate them and whether or not they had implants. The statistical analysis included descriptive statistics for the study population. We used the Mann-Whitney U to compare the mean glandular dose and dose in the thyroid gland and lens between groups. Results: The mean glandular dose and the dose of radiation received in the thyroid and lens were within the acceptable range. In a few exceptions, the mean glandular dose per view was slightly higher than 3 mGy. The scatter dose to the thyroid gland and the lens during mammography has a very small contribution to the annual dose equivalent. Conclusion: The mean glandular dose and the scatter dose to the thyroid gland and lens delivered during tomosynthesis and 2D mammography in women with implants were higher than those delivered during other mammographic techniques in women without implants. (C) 2021 SERAM. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:S11 / S19
页数:9
相关论文
共 22 条
  • [1] Mean glandular dose in digital mamography in women with breast implants
    Couto, Lilian Soares
    Freitas-Junior, Ruffo
    Correa, Rosangela Silveira
    Peixoto, Joao Emilio
    Almeida, Claudio Domingues
    Netto Rodrigues, Danielle Cristina
    Glassman, Leonard M.
    Soares, Leonardo Ribeiro
    JOURNAL OF RADIOLOGICAL PROTECTION, 2019, 39 (02) : 498 - 510
  • [2] Evaluating dose to thyroid gland in women with breast cancer during radiotherapy with different radiation energies at supraclavicular fossa region
    Mirsadraei, Marjaneh
    Toosi, Mehdi Seilanian
    Mohebbi, Shokoufeh
    Khalili-Hezarjaribi, Hojjat
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (04) : 373 - 376
  • [3] Assessment of scatter radiation dose and absorbed doses in eye lens and thyroid gland during digital breast tomosynthesis
    Chusin, Thunyarat
    Matsubara, Kosuke
    Takemura, Akihiro
    Okubo, Rena
    Ogawa, Yoshinori
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 340 - 347
  • [4] An estimate of radiation dose to the lens of the eyes, parotid gland, and thyroid gland in dental panoramic radiography
    Naserpour F.
    Hassanpour N.
    Panahi F.
    Karami V.
    Gholami M.
    Iranian Journal of Medical Physics, 2019, 16 (06): : 425 - 429
  • [5] Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CT
    Zammit-Maempel, I
    Chadwick, CL
    Willis, SP
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (906): : 418 - 420
  • [6] CHARACTERISATION OF TLDS-200 AND OSLDS AT LOW X-RAY ENERGIES AND DETERMINATION OF EYE LENS DOSE, THYROID DOSE AND MEAN GLANDULAR DOSE DURING STANDARD MAMMOGRAPHY AND TOMOSYNTHESIS
    Pirchio, R.
    Stefanic, A.
    Rojas, R. R.
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (04) : 469 - 478
  • [7] RADIATION-DOSE TO THE OCULAR LENS AND THYROID-GLAND DURING HIGH-RESOLUTION CT OF THE TEETH
    SCHULLER, H
    KOSTER, O
    EWEN, K
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (02): : 189 - 192
  • [8] Evaluation of the radiation dose in the thyroid gland using different protective collars in panoramic imaging
    Hafezi, Ladan
    Arianezhad, S. Marjan
    Pooya, Seyed Mahdi Hosseini
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (06)
  • [9] Radiation Dose to the Thyroid Gland and Breast From Multidetector Computed Tomography of the Cervical Spine: Does Bismuth Shielding With and Without a Cervical Collar Reduce Dose?
    Gunn, Martin L.
    Kanal, Kalpana M.
    Kolokythas, Orpheus
    Anzai, Yoshimi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (06) : 987 - 990
  • [10] Dose Fractionation During Puberty Is More Detrimental to Mammary Gland Development Than an Equivalent Acute Dose of Radiation Exposure
    Wiedmeyer, Brandi
    To, Jennifer
    Sridharan, Deepa M.
    Chien, Lung-Chang
    Snijders, Antoine M.
    Mori, Hidetoshi
    Pluth, Janice M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 109 (05): : 1521 - 1532