MRI-Compatible Optically-Sensed Cello

被引:0
|
作者
Hollinger, Avrum D. [1 ]
Wanderley, Marcelo M. [1 ]
机构
[1] McGill Univ, Schulich Sch Mus, Input Devices & Mus Interact Lab IDMIL, Ctr Interdisciplinary Res Mus Media & Technol CIR, Montreal, PQ, Canada
来源
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An opto-acoustic cello has been designed to investigate the neural correlates of cello performance using functional magnetic resonance imaging (MRI). Through the design of specialized optical sensors, for the first time, we are able to synchronously capture a cellist's acoustic performance and musical gestures within the MRI scanner. The electromagnetic constraints and confined space of the scanner were overcome through the design of a minimalist composite cello body, a bridge and transparent fingerboard embedded with optical fibers, and a sensorized shortened bow. Using an array of fibers embedded in the fingerboard, we captured finger position and vibrato. Bending losses in fibers placed between the bridge and string, as a contact microphone, allowed us to capture the acoustic performance. Bow displacement was acquired separately using an optical flow sensor and by measuring Faraday rotation in an optical crystal within the magnetic field of the scanner.
引用
收藏
页码:1928 / 1931
页数:4
相关论文
共 50 条
  • [41] MRI-compatible procedures for behavioral pharmacology in squirrel monkeys
    Delatte, Marcus Sherode
    Brimson, Melanie
    Rohan, Michael
    Kaufman, Marc
    Bergman, Jack
    FASEB JOURNAL, 2007, 21 (05): : A411 - A411
  • [42] Development of an MRI-compatible digital SiPM detector stack for simultaneous PET/MRI
    Duppenbecker, Peter M.
    Weissler, Bjoern
    Gebhardt, Pierre
    Schug, David
    Wehner, Jakob
    Marsden, Paul K.
    Schulz, Volkmar
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (01):
  • [43] MRI-compatible Micromanipulator: Positioning Repeatability Tests & Kinematic Calibration
    Koseki, Yoshihiko
    Tanikawa, Tamio
    Chinzei, Kiyoyuki
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5118 - +
  • [44] A SiPM-Based Clinical MRI-Compatible SPECT Insert
    Carminati, M.
    D'Adda, I.
    Morahan, A. J.
    Erlandsson, K.
    Nagy, K.
    Nyitrai, Z.
    Czeller, M.
    Moresco, R.
    Savi, A.
    Van Mullekom, P.
    Hutton, B. F.
    Fiorini, C.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [45] Development of a QCT- and MRI-compatible Muscle Phantom.
    Wong, Andy Kin On
    Merali, Zamir
    Adachi, Jonathan
    JOURNAL OF BONE AND MINERAL RESEARCH, 2014, 29 : S341 - S342
  • [46] A very inexpensive MRI-compatible method for dichoptic visual stimulation
    Schurger, Aaron
    JOURNAL OF NEUROSCIENCE METHODS, 2009, 177 (01) : 199 - 202
  • [47] Design and Analysis of A Novel MRI-compatible Breast Biopsy Robot
    Lu, Mingyue
    Zhang, Yongde
    Hu, Zhaoli
    Du, Haiyan
    Niu, Suoliang
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2018, : 1238 - 1243
  • [48] MRI-compatible pneumatic robot for transperineal prostate needle placement
    Fischer, Gregory S.
    Iordachita, Iulian
    Csoma, Csaba
    Tokuda, Junichi
    DiMaio, Simon P.
    Tempany, Clare M.
    Hata, Nobuhiko
    Fichtinger, Gabor
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2008, 13 (03) : 295 - 305
  • [49] Comparison of MRI-compatible mechatronic systems with hydrodynamic and pneumatic actuation
    Yu, Ningbo
    Hollnagel, Christoph
    Blickenstorfer, Armin
    Kollias, Spyros S.
    Riener, Robert
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2008, 13 (03) : 268 - 277
  • [50] MRI-compatible audio/visual system: impact on pediatric sedation
    Harned, RK
    Strain, JD
    PEDIATRIC RADIOLOGY, 2001, 31 (04) : 247 - 250