MRI-Compatible Optically-Sensed Cello

被引:0
|
作者
Hollinger, Avrum D. [1 ]
Wanderley, Marcelo M. [1 ]
机构
[1] McGill Univ, Schulich Sch Mus, Input Devices & Mus Interact Lab IDMIL, Ctr Interdisciplinary Res Mus Media & Technol CIR, Montreal, PQ, Canada
来源
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An opto-acoustic cello has been designed to investigate the neural correlates of cello performance using functional magnetic resonance imaging (MRI). Through the design of specialized optical sensors, for the first time, we are able to synchronously capture a cellist's acoustic performance and musical gestures within the MRI scanner. The electromagnetic constraints and confined space of the scanner were overcome through the design of a minimalist composite cello body, a bridge and transparent fingerboard embedded with optical fibers, and a sensorized shortened bow. Using an array of fibers embedded in the fingerboard, we captured finger position and vibrato. Bending losses in fibers placed between the bridge and string, as a contact microphone, allowed us to capture the acoustic performance. Bow displacement was acquired separately using an optical flow sensor and by measuring Faraday rotation in an optical crystal within the magnetic field of the scanner.
引用
收藏
页码:1928 / 1931
页数:4
相关论文
共 50 条
  • [11] A modular approach to MRI-compatible robotics
    Elhawary, Haytham
    Zivanovic, Aleksandar
    Rea, Marc
    Davies, Brian L.
    Besant, Collin
    McRobbie, Donald
    Desouza, Nandita M.
    Young, Ian
    Lamperth, Michael U.
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2008, 27 (03): : 35 - 41
  • [12] Silicon photomultiplier modules for MRI-compatible PET
    Sul, Woo-Suk
    Kim, Hyoungtaek
    Cho, Gyuseong
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [13] The modelling and design of an MRI-compatible cryosurgical probe
    Kossel, L.
    Pfotenhauer, J.
    Harter, R.
    ADVANCES IN CRYOGENIC ENGINEERING, 2020, 755
  • [14] Design of MRI-Compatible Hemiparesis Rehabilitation Device
    Lacey, Lauren
    Maliki, Arnold
    Bhattacharjee, Debapriya
    Veldhorst, James
    Ueda, Jun
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2014, 8 (02):
  • [15] Accuracy of MRI-Compatible Contrast Media Injectors
    Saake, M.
    Wuest, W.
    Becker, S.
    Uder, M.
    Janka, R.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (03): : 253 - 259
  • [16] An MRI-compatible hand sensory vibrotactile system
    Wang, Fa
    Lakshminarayanan, Kishor
    Slota, Gregory P.
    Seo, Na Jin
    Webster, John G.
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (01) : N15 - N21
  • [17] MRI-compatible pneumatic stimulator for sensorimotor mapping
    Lolli, Valentina
    Rovai, Antonin
    Trotta, Nicola
    Bourguignon, Mathieu
    Goldman, Serge
    Sadeghi, Niloufar
    Jousmaki, Veikko
    De Tiege, Xavier
    JOURNAL OF NEUROSCIENCE METHODS, 2019, 313 : 29 - 36
  • [18] MRI-compatible Fluid-Powered Medical Devices
    Ueda, Jun
    Comber, David B.
    Slightam, Jonathon
    Turkseven, Melih
    Gervasi, Vito
    Webster, Robert J., III
    Barth, Eric J.
    MECHANICAL ENGINEERING, 2013, 135 (06) : 71 - 74
  • [19] MRI-compatible wearable actuator for measuring sense of agency
    Tanaka, Shota
    Suzumori, Koichi
    Nabae, Hiroyuki
    Yoshida, Takako
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 2016, 51 : 1025 - 1025
  • [20] An MRI-compatible defibrillator: initial testing in volunteers and swine
    Ehud J Schmidt
    Ronald D Watkins
    Menekhem M Zviman
    Michael Guttman
    Wei Wang
    Henry Halperin
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)