MRI-Compatible Optically-Sensed Cello

被引:0
|
作者
Hollinger, Avrum D. [1 ]
Wanderley, Marcelo M. [1 ]
机构
[1] McGill Univ, Schulich Sch Mus, Input Devices & Mus Interact Lab IDMIL, Ctr Interdisciplinary Res Mus Media & Technol CIR, Montreal, PQ, Canada
来源
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An opto-acoustic cello has been designed to investigate the neural correlates of cello performance using functional magnetic resonance imaging (MRI). Through the design of specialized optical sensors, for the first time, we are able to synchronously capture a cellist's acoustic performance and musical gestures within the MRI scanner. The electromagnetic constraints and confined space of the scanner were overcome through the design of a minimalist composite cello body, a bridge and transparent fingerboard embedded with optical fibers, and a sensorized shortened bow. Using an array of fibers embedded in the fingerboard, we captured finger position and vibrato. Bending losses in fibers placed between the bridge and string, as a contact microphone, allowed us to capture the acoustic performance. Bow displacement was acquired separately using an optical flow sensor and by measuring Faraday rotation in an optical crystal within the magnetic field of the scanner.
引用
收藏
页码:1928 / 1931
页数:4
相关论文
共 50 条
  • [21] MRI-compatible ultrasonic probe for minimally invasive therapy
    Azuma, T
    Sasaki, K
    Kawabata, KI
    Osada, A
    Itagaki, H
    Komura, K
    Takahashi, T
    Ishida, K
    Satoh, Y
    Umemura, SI
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1465 - 1468
  • [22] Design and evaluation of an MRI-compatible linear motion stage
    Tavallaei, Mohammad Ali
    Johnson, Patricia M.
    Liu, Junmin
    Drangova, Maria
    MEDICAL PHYSICS, 2016, 43 (01) : 62 - 71
  • [23] MRI-compatible titanium ventriculostomy kit: Technical note
    Schaller, C
    Pavlidis, C
    ACTA NEUROCHIRURGICA, 1996, 138 (11) : 1320 - 1322
  • [24] Design and Analysis of an MRI-Compatible Soft Needle Manipulator
    Chen, Jie
    Zhang, Jingyu
    Jiang, Tianyu
    Dang, Yu
    Han, Jianda
    ACTUATORS, 2024, 13 (02)
  • [25] Development of MRI-Compatible Nuclear Medicine Imaging Detectors
    Wagenaar, D. J.
    Nalcioglu, O.
    Muftuler, L. T.
    Szawlowski, M.
    Kapusta, M.
    Pavlov, N.
    Meier, D.
    Maehlum, G.
    Patt, B. E.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1825 - 1828
  • [26] MRI-compatible micromanipulator - Design and implementation and MRI-compatibility tests
    Koseki, Yoshihiko
    Tanikawa, Tamio
    Chinzei, Kiyoyuki
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 465 - +
  • [27] Design and Fabrication of an MRI-Compatible, Autonomous Incubation System
    Vahid Khalilzad-Sharghi
    Huihui Xu
    Annals of Biomedical Engineering, 2015, 43 : 2406 - 2415
  • [28] Improved methods for MRI-compatible implants in nonhuman primates
    Ortiz-Rios, Michael
    Haag, Marcus
    Balezeau, Fabien
    Frey, Stephen
    Thiele, Alex
    Murphy, Kathy
    Schmid, Michael Christoph
    JOURNAL OF NEUROSCIENCE METHODS, 2018, 308 : 377 - 389
  • [29] Development of a sterilizable MRI-compatible manipulator for stereotactic neurosurgery
    Nakamura, R
    Masamune, K
    Nishikawa, Y
    Kobayashi, E
    Sakuma, I
    Dohi, T
    Iseki, H
    Takakura, K
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 1019 - 1019
  • [30] MRI-Compatible Injection System for Magnetic Microparticle Embolization
    Li, Ning
    Michaud, Francois
    Nosrati, Zeynab
    Loghin, Dumitru
    Tremblay, Charles
    Plantefeve, Rosalie
    Saatchi, Katayoun
    Hafeli, Urs O.
    Martel, Sylvain
    Soulez, Gilles
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (08) : 2331 - 2340