MRI-Compatible Optically-Sensed Cello

被引:0
|
作者
Hollinger, Avrum D. [1 ]
Wanderley, Marcelo M. [1 ]
机构
[1] McGill Univ, Schulich Sch Mus, Input Devices & Mus Interact Lab IDMIL, Ctr Interdisciplinary Res Mus Media & Technol CIR, Montreal, PQ, Canada
来源
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An opto-acoustic cello has been designed to investigate the neural correlates of cello performance using functional magnetic resonance imaging (MRI). Through the design of specialized optical sensors, for the first time, we are able to synchronously capture a cellist's acoustic performance and musical gestures within the MRI scanner. The electromagnetic constraints and confined space of the scanner were overcome through the design of a minimalist composite cello body, a bridge and transparent fingerboard embedded with optical fibers, and a sensorized shortened bow. Using an array of fibers embedded in the fingerboard, we captured finger position and vibrato. Bending losses in fibers placed between the bridge and string, as a contact microphone, allowed us to capture the acoustic performance. Bow displacement was acquired separately using an optical flow sensor and by measuring Faraday rotation in an optical crystal within the magnetic field of the scanner.
引用
收藏
页码:1928 / 1931
页数:4
相关论文
共 50 条
  • [1] The Design, Implementation, and Testing of a Sensorized MRI-Compatible Cello
    Hollinger, Avrum D.
    Wanderley, Marcelo M.
    IEEE SENSORS JOURNAL, 2015, 15 (11) : 6125 - 6134
  • [2] MRI-compatible robotics
    Gassert, Roger
    Burdet, Etienne
    Chinzei, Kiyoyuki
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2008, 27 (03): : 12 - 14
  • [3] The MRI-compatible mammotome
    Daniel, BL
    Freeman, LJ
    Pyzoha, JM
    McCoy, TD
    Birdwell, RL
    Bouley, D
    RADIOLOGY, 2000, 217 : 266 - 267
  • [4] Characterization of optically actuated MRI-compatible active needles for medical interventions
    Black, Richard J.
    Ryu, Seokchang
    Moslehi, Behzad
    Costa, Joannes M.
    BEHAVIOR AND MECHANICS OF MULTIFUNCTIONAL MATERIALS AND COMPOSITES 2014, 2014, 9058
  • [5] MRI-compatible Pacemaker System
    Ridder, Karsten
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (10): : 971 - 971
  • [6] Special MRI-Compatible Leads
    Hansky, Bert
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2012, 109 (39): : 643 - 644
  • [7] The MRI-compatible neonatal incubator in practice
    Lane, Annah
    Chuk, Lai-Man R.
    Colditz, Paul B.
    Coulthard, Alan
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2013, 49 (09) : E377 - E380
  • [8] MRI-compatible cardiac pacing catheter
    Hofman, MBM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) : 612 - 612
  • [9] Special MRI-Compatible Leads Reply
    Zobel, Carsten
    Bovenschulte, Henning
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2012, 109 (39): : 644 - 644
  • [10] A MRI-compatible system for whisker stimulation
    Li, Limin
    Weiss, Craig
    Talk, Andrew C.
    Disterhoft, John F.
    Wyrwicz, Alice M.
    JOURNAL OF NEUROSCIENCE METHODS, 2012, 205 (02) : 305 - 311