3D-OSEM reconstruction from truncated data in pinhole SPECT

被引:0
|
作者
Zeniya, Tsutomu [1 ]
Watabe, Hiroshi [1 ]
Sohlberg, Antti [2 ,3 ]
Inomata, Toru [1 ]
Kudo, Hiroyuki [4 ]
Iida, Hidehiro [1 ]
机构
[1] Natl Cardiovasc Ctr, Res Inst, Adv Med Engn Ctr, Dept Investigat Radiol, 5-7-1 Fujishirodai, Osaka 5658565, Japan
[2] Natl Cardiovasc Ctr Hosp & Res Inst, Osaka, Japan
[3] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, Kuopio, Finland
[4] Univ Tsukuba, Grad Sch Syst & Informat Engn, Dept Comp Sci, Tsukuba, Ibaraki, Japan
基金
日本科学技术振兴机构;
关键词
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
Pinhole SPECT can provide high-resolution image with high sensitivity when a collimator is close to an object. However, truncation causes artifact and decreases quantitative accuracy. Defrise et al proposed new reconstruction theory to prevent overestimation due to truncation. In this paper, we applied Defrise theory to three-dimensional pinhole SPECT reconstruction and validated our implementation by computer simulation.
引用
收藏
页码:4205 / 4207
页数:3
相关论文
共 50 条
  • [31] A comparison of the 3D-OSEM, 3DRP and rebinning algorithms for brain lesion detectability.
    Baghaei, H
    Uribe, J
    Li, H
    Wang, Y
    Liu, Y
    Xing, T
    Farrell, R
    Xie, S
    Wong, WH
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 278P - 279P
  • [32] Exact emission SPECT reconstruction with truncated transmission data
    Zeng, Gengsheng
    Gullberg, Grant
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [33] A method of overlap correction for fully 3D OSEM reconstruction of PET data
    Ross, S
    Stearns, C
    Manjeshwar, R
    Iatrou, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3497 - 3500
  • [34] Communication optimization and auto load balancing in parallel OSEM algorithm for fully 3-D SPECT reconstruction
    Ma Tianyu
    Zhou Rong
    Jin Yongjie
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2695 - 2699
  • [35] SPECT region of interest reconstruction with truncated transmission and emission data
    Zeng, Gengsheng L.
    Gullberg, Grant T.
    MEDICAL PHYSICS, 2010, 37 (09) : 4627 - 4633
  • [36] Attenuation map and emission activity reconstruction from truncated SPECT emission data.
    Panin, VY
    Zeng, GL
    Gullberg, GT
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 134P - 134P
  • [37] 3D-OSEM transition matrix for high resolution PET imaging with modeling of the gamma-event detection
    Ortuño, JE
    Kontaxakis, G
    Guerra, P
    Santos, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3046 - 3050
  • [38] Optimizing the number of equivalent iterations of 3D OSEM in SPECT reconstruction of I-131 focal activities
    Koral, Kenneth F.
    Kritzmaan, James N.
    Rogers, Virginia E.
    Ackermann, Robert J.
    Fessler, Jeffrey A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 326 - 329
  • [39] Analysis of a SPECT OSEM reconstruction method with 3D beam modeling and optional attenuation correction: Phantom studies
    Vija, AH
    Hawman, EG
    Engdahl, JC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2662 - 2666
  • [40] HeinzelCluster:: accelerated reconstruction for FORE and OSEM3D
    Vollmar, S
    Michel, C
    Treffert, JT
    Newport, DF
    Casey, M
    Knöss, C
    Wienhard, K
    Liu, X
    Defrise, M
    Heiss, WD
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1766 - 1770