3D-OSEM reconstruction from truncated data in pinhole SPECT

被引:0
|
作者
Zeniya, Tsutomu [1 ]
Watabe, Hiroshi [1 ]
Sohlberg, Antti [2 ,3 ]
Inomata, Toru [1 ]
Kudo, Hiroyuki [4 ]
Iida, Hidehiro [1 ]
机构
[1] Natl Cardiovasc Ctr, Res Inst, Adv Med Engn Ctr, Dept Investigat Radiol, 5-7-1 Fujishirodai, Osaka 5658565, Japan
[2] Natl Cardiovasc Ctr Hosp & Res Inst, Osaka, Japan
[3] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, Kuopio, Finland
[4] Univ Tsukuba, Grad Sch Syst & Informat Engn, Dept Comp Sci, Tsukuba, Ibaraki, Japan
基金
日本科学技术振兴机构;
关键词
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
Pinhole SPECT can provide high-resolution image with high sensitivity when a collimator is close to an object. However, truncation causes artifact and decreases quantitative accuracy. Defrise et al proposed new reconstruction theory to prevent overestimation due to truncation. In this paper, we applied Defrise theory to three-dimensional pinhole SPECT reconstruction and validated our implementation by computer simulation.
引用
收藏
页码:4205 / 4207
页数:3
相关论文
共 50 条
  • [21] Parallel OSEM reconstruction algorithm for fully 3-D SPECT on a beowulf cluster
    Zhou Rong
    Ma Tianyu
    Jin Yongjie
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1834 - 1837
  • [22] Image reconstruction from truncated data in SPECT with uniform attenuation
    Noo, Frederic
    Defrise, Michel
    Pack, Jed D.
    Clackdoyle, Rolf
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2288 - 2292
  • [23] Quantification of cerebral blood flow (CBF) by means of SPECT-CT with 3D-OSEM reconstruction algorithm: A comparison with H215O PET measurement
    Okusu, Ikuko
    Shimosegawa, Eku
    Fujino, Kouichi
    Kato, Hiroki
    Watabe, Hiroshi
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [24] Fast reconstruction of truncated transmission SPECT data
    Riddell, C
    Savi, A
    Gilardi, MC
    Fazio, F
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1107 - 1110
  • [25] Comparison of Myocardial Blood Flow quantification for 13NH3 and 3D-PET by using different image reconstruction algorithms (3D-Reprojection, 3D-OSEM, 3D-OSEM with Time-of-Fligth and 3D-Point-Spread-Function) and De-Grado Model.
    Presotto, L.
    Busnardo, E.
    Bettinardi, V.
    Landoni, C.
    Todeschini, P.
    Rimoldi, O.
    Gilardi, M. C.
    Gianolli, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S500 - S501
  • [26] Comparison of 10 versus 20 mm SPECT 99mTc-MDP bone scans: use of 3D-OSEM image reconstruction with distance-dependent resolution modelling
    Livieratos, Lefteris
    Mohan, Hosahalli
    Gnanasegaran, Gopinath
    Fogelman, Ignac
    NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (12) : 1045 - 1053
  • [27] Development of fully 3D image reconstruction techniques for pinhole SPECT imaging
    Zhang XueZhu
    Qi YuJin
    CHINESE SCIENCE BULLETIN, 2011, 56 (03): : 340 - 348
  • [28] Development of fully 3D image reconstruction techniques for pinhole SPECT imaging
    ZHANG XueZhu1
    2 Graduate University of Chinese Academy of Sciences
    Science Bulletin, 2011, (03) : 340 - 348
  • [29] Image Quality and Data Quantification in Dopamine Transporter SPECT Advantage of 3-Dimensional OSEM Reconstruction?
    Winz, Oliver H.
    Hellwig, Sabine
    Mix, Michael
    Weber, Wolfgang A.
    Mottaghy, Felix M.
    Schaefer, Wolfgang M.
    Meyer, Philipp T.
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (09) : 866 - 871
  • [30] Exact emission SPECT reconstruction with truncated transmission data
    Zeng, Gengsheng L.
    Gullberg, Grant T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (11): : 3329 - 3340