Hand-held steerable needle device

被引:0
|
作者
Ebrahimi, R [1 ]
Okazawa, S [1 ]
Rohling, R [1 ]
Salcudean, SE [1 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V5Z 1M9, Canada
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents a novel handheld device for steerable needle insertions for minimally invasive percutaneous procedures. Controlled lateral deflection of over 30mm during a 100mm axial insertion is demonstrated with a 20 gauge needle. A handheld, motorized device has been built to control the direction and rate of steering according to a two-axis miniature joystick input. To facilitate interventions with this steerable needle, two methods of locating the needle and its tip using ultrasound imaging are presented. One uses needle tip vibration for colour/power Doppler-based localization, the other is based on real-time segmentation of B-mode images.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [21] Hand-Held Robotic Device for Laparoscopic Surgery and Training
    Pereira, Ricardo
    Moreira, Antonio H. J.
    Leite, Mariana
    Rodrigues, Pedro L.
    Queiros, Sandro
    Rodrigues, Nuno F.
    Leao, Pedro
    Vilaca, Joao L.
    2014 IEEE 3RD INTERNATIONAL CONFERENCE ON SERIOUS GAMES AND APPLICATIONS FOR HEALTH (SEGAH), 2014,
  • [22] A Smart Haptic Hand-Held Device for Neurosurgical Microdissection
    Christopher J. Payne
    Hani J. Marcus
    Guang-Zhong Yang
    Annals of Biomedical Engineering, 2015, 43 : 2185 - 2195
  • [23] Alternative sensor for the screening of cannabinoids with a hand-held device
    Tay, Li-Lin
    Jorgenson, Emma
    Poirier, Shawn
    Hulse, John
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [24] Surface normal imaging with a hand-held NMR device
    Brown, MCA
    Verganelakis, DA
    Mallett, MJD
    Mitchell, J
    Blümler, P
    JOURNAL OF MAGNETIC RESONANCE, 2004, 169 (02) : 308 - 312
  • [25] Development and Assessment of a Hand-Held Dust Measuring Device
    Khan K.
    Bano Z.
    Dixit J.
    Peerzada H.A.
    Ali M.
    Journal of The Institution of Engineers (India): Series A, 2024, 105 (3) : 499 - 505
  • [26] A novel hand-held device for the measurement of ocular alignment
    Altiparmak, Ugur E.
    Karabulut, Esra
    Eggenberger, Eric R.
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2010, 40 (04) : 511 - 514
  • [27] HAND-HELD - UPWARD MOBILITY THROUGH HAND-HELD TRANSCEIVERS
    GUSTAFSON, D
    AIR PROGRESS, 1985, 47 (03): : 30 - 32
  • [28] A Smart Haptic Hand-Held Device for Neurosurgical Microdissection
    Payne, Christopher J.
    Marcus, Hani J.
    Yang, Guang-Zhong
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (09) : 2185 - 2195
  • [29] Fatigue evaluation of a hand-held device for the automated colonoscope
    Sheerer, Corey
    Choi, JungHun
    Medical Devices and Sensors, 2019, 2 (5-6):
  • [30] Diagnostics Hand-held device monitors blood clotting
    Dorey, Emma
    CHEMISTRY & INDUSTRY, 2011, (06) : 8 - 8