Hand-held steerable needle device

被引:0
|
作者
Ebrahimi, R [1 ]
Okazawa, S [1 ]
Rohling, R [1 ]
Salcudean, SE [1 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V5Z 1M9, Canada
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents a novel handheld device for steerable needle insertions for minimally invasive percutaneous procedures. Controlled lateral deflection of over 30mm during a 100mm axial insertion is demonstrated with a 20 gauge needle. A handheld, motorized device has been built to control the direction and rate of steering according to a two-axis miniature joystick input. To facilitate interventions with this steerable needle, two methods of locating the needle and its tip using ultrasound imaging are presented. One uses needle tip vibration for colour/power Doppler-based localization, the other is based on real-time segmentation of B-mode images.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [42] A HAND-HELD KERATOMETER
    LAM, AKC
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1995, 15 (03) : 227 - 230
  • [43] HAND-HELD MYOMETRY
    BOHANNON, RW
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1992, 55 (10): : 982 - 982
  • [44] A SIMPLE HAND-HELD DEVICE FOR THE ND-YAG LASER
    BARRIOLA, JA
    SHAPSHAY, SM
    SURGERY GYNECOLOGY & OBSTETRICS, 1986, 163 (05): : 489 - 490
  • [45] Robust cDNA microarray image processing on a hand-held device
    Gomez, P.
    Diaz, F.
    Belean, B.
    Malutan, R.
    Stetter, B.
    Martinez, R.
    Rodellar, V.
    RECONFIG 2006: PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL CONFERENCE ON RECONFIGURABLE COMPUTING AND FPGA'S, 2006, : 245 - +
  • [46] Validation of a hand-held ultrasound device in the evaluation of aortic stenosis
    Zamacola, J. Zubiaur
    De Castro, A. Margarida
    Barquin, R. Perez
    Gonzalez, M. Lozano
    Ruiz, N. Gutierrez
    Alarcos, H.
    Vilchez, F. Gonzalez
    Villar, C. Ruisanchez
    Serrano, D.
    Cosgaya, J. M. Cuesta
    Coroas, C.
    Prejigueiro, L. Munoz
    Abia, L.
    De la Torre, J. M.
    De Prada, J. A. Vazquez
    EUROPEAN HEART JOURNAL, 2024, 45
  • [47] POCKET PERMEAMETER - HAND-HELD DEVICE FOR RAPID MEASUREMENT OF PERMEABILITY
    BRADLEY, JS
    DUSCHATK.RW
    HINCH, HH
    AMERICAN ASSOCIATION OF PETROLEUM GEOLOGISTS BULLETIN, 1972, 56 (03): : 568 - &
  • [48] HAND-HELD GRAFTING DEVICE FOR MAKING UNIFORM WEDGE CUTS
    WHITE, MC
    AGRONOMY JOURNAL, 1979, 71 (01) : 141 - 144
  • [49] Using acoustic structure in a hand-held audio playback device
    Schmandt, C
    Roy, D
    IBM SYSTEMS JOURNAL, 1996, 35 (3-4) : 453 - 472
  • [50] Assessment of exhaled nitric oxide by a new hand-held device
    Antus, Balazs
    Horvath, Ildiko
    Barta, Imre
    RESPIRATORY MEDICINE, 2010, 104 (09) : 1377 - 1380