Fatigue evaluation of a hand-held device for the automated colonoscope

被引:0
|
作者
Sheerer, Corey [1 ]
Choi, JungHun [2 ]
机构
[1] Department of Mechanical Engineering, Ohio University, Athens,OH, United States
[2] Department of Mechanical Engineering, Georgia Southern University, Statesboro,GA, United States
来源
Medical Devices and Sensors | 2019年 / 2卷 / 5-6期
关键词
Diseases;
D O I
10.1002/mds3.10051
中图分类号
学科分类号
摘要
As knowledge about the colorectal disease becomes more widespread, an increasing demand for screening and high standards arises. This study focuses on the fatigue measurement of a prototype colonoscope that incorporates a holding structure to support the colonoscope and a hand-held device that actuates distal tip steering. Experimentation was performed to compare the fatigue and learning curve of the prototype scope to a conventional scope. Fatigue was measured as a reduction in force corresponding to the maximum voluntary contraction of the left thumb and forearm. Results show that subjects using the conventional scope did not experience significant reduction in force in either the thumb or the forearm, while the prototype scope resulted in a force reduction of 17% and 16% in the forearm and thumb, respectively. Caecal intubation time and learning rate showed no significant decrease while using the prototype scope compared with a conventional scope to ensure the functionality of the prototype scope. © 2019 Wiley Periodicals, Inc.
引用
收藏
相关论文
共 50 条
  • [1] A Hand-Held Device for Controlling a Mounted, Motor Driven Colonoscope
    Sheerer, Corey D.
    Drozek, David
    Choi, Junghun
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (03):
  • [2] Hand-Held Device
    Hadas, Rachel
    HUDSON REVIEW, 2019, 71 (04): : 791 - 794
  • [3] Hand-held ECG device
    Mohan, Alladi
    NATIONAL MEDICAL JOURNAL OF INDIA, 2018, 31 (06): : 382 - 382
  • [4] Evaluation of an electronic hand-held device for measurement of β-hydroxybutyrate in ewes
    Pichler, M.
    Gasteiner, J.
    Schwendenwein, I.
    Damberger, A.
    Drillich, M.
    Iwersen, M.
    REPRODUCTION IN DOMESTIC ANIMALS, 2012, 47 : 69 - 69
  • [5] EVALUATION OF MECHANIZED FLOSSING DEVICE COMPARED TO HAND-HELD FLOSSING
    BARTON, R
    DIAMOND, B
    JOURNAL OF DENTAL RESEARCH, 1980, 59 : 537 - 537
  • [6] Validation of a hand-held ultrasound device in the evaluation of aortic stenosis
    Jon Zubiaur
    Adrián de Margarida Castro
    Raquel Pérez-Barquín
    Manuel Lozano Gonzalez
    Gonzalo Martin Gorria
    Luis Javier Ruiz Guerrero
    Andrea Teira Calderon
    Ignacio Santiago Setien
    David Serrano Lozano
    Francisco González Vílchez
    Jose Antonio Vázquez de Prada Tiffe
    The International Journal of Cardiovascular Imaging, 2025, 41 (2) : 377 - 385
  • [7] Evaluation of a coulometric hand-held blood glucose monitoring device
    Toffaletti, JG
    McDonnell, EH
    CLINICAL CHEMISTRY, 2005, 51 : A32 - A32
  • [8] Hand-held steerable needle device
    Ebrahimi, R
    Okazawa, S
    Rohling, R
    Salcudean, SE
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 223 - 230
  • [9] Hand-held steerable needle device
    Okazawa, S
    Ebrahimi, R
    Chuang, J
    Salcudean, SE
    Rohling, R
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2005, 10 (03) : 285 - 296
  • [10] Hand-held device tests for drugs
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 31 : X - X