Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CT

被引:1
|
作者
Zucca, Sergio
Carau, Barbara
Solla, Ignazio
Garibaldi, Elisabetta
Farace, Paolo [1 ]
Lay, Giancarlo
Meleddu, Gianfranco
Gabriele, Pietro [1 ]
机构
[1] Reg Oncol Hosp, Dept Radiooncol, I-09121 Cagliari, Italy
关键词
Megavolt cone-beam CT; IGRT; Prostate; Radiotherapy; INTENSITY-MODULATED RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; FIDUCIAL MARKERS; GOLD MARKERS; BONY ANATOMY; LOCALIZATION; ONLINE; CANCER; SETUP;
D O I
10.1007/s00066-011-2241-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To test megavolt cone-beam CT (MV-CBCT) in order to evaluate setup errors in prostate radiotherapy. Patients and Methods: The setup of 9 patients was verified weekly by electronic portal imaging (EPI) and MV-CBCT, both performed in the same treatment session. EPI were compared with digitally reconstructed radiographies (DRRs). MV-CBCTs were matched to simulation CTs by manual registration based on bone markers (BMR), by manual registration based on soft tissues (STR) - rectum, bladder, and seminal vesicles - and by automatic registration (AR) performed by a mutual information algorithm. Shifts were evaluated along the three main axes: anteroposterior (AP), craniocaudal (CC), and laterolateral (LL). Finally, in 4 additional patients showing intraprostatic calcifications, the calcification mismatch error was used to evaluate the three MV-CBCT matching methods. Results: A total of 50 pairs of orthogonal EPIs and 50 MV-CBCTs were analyzed. Assuming an overall tolerance of 2 mm, no significant differences were observed comparing EPI vs BMR in any axis. A significant difference (p<0.001) was observed along the AP axis comparing EPI vs AR and EPI vs STR. On the calcification data set (22 measures), the calcification mismatch along the AP direction was significantly lower (p<0.05) after STR than after BMR or AR. Conclusion: Bone markers were not an effective surrogate of the target position and significant differences were observed comparing EPI or BMR vs STR, supporting the assessment of soft tissue position by MVCBs to verify and correct patient setup in prostate radiotherapy.
引用
收藏
页码:473 / 478
页数:6
相关论文
共 50 条
  • [41] Fusion of Intraoperative Cone-Beam CT and Endoscopic Video for Image-Guided Procedures
    Daly, M. J.
    Chan, H.
    Prisman, E.
    Vescan, A.
    Nithiananthan, S.
    Qiu, J.
    Weersink, R.
    Irish, J. C.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [42] Kilo-voltage cone-beam CT for image-guided radiation therapy
    Sonke, JJ
    Remeijer, P
    Betgen, A
    Lebesque, J
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S70 - S70
  • [43] An Optimized Protocol for Using Small Field MV Cone-Beam CT Imaging in Image-Guided Radiotherapy (IGRT)
    Yembi-Goma, G.
    Lu, L.
    Li, K.
    Wang, J.
    Zhang, H.
    Martin, D.
    Gupta, N.
    MEDICAL PHYSICS, 2009, 36 (06) : 2478 - +
  • [44] Precision of three dimensional image-guided radiotherapy (IGRT) using cone-beam CT and hexapod in clinical practice
    Guckenberge, M.
    Wilbert, J.
    Richter, A.
    Baier, K.
    Meyer, J.
    Sauer, O.
    Flentje, M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S146 - S146
  • [45] Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors
    Guckenberger, Matthias
    Meyer, Juergen
    Wilbert, Juergen
    Richter, Anne
    Baier, Kurt
    Mueller, Gerd
    Flentje, Michael
    RADIOTHERAPY AND ONCOLOGY, 2007, 83 (01) : 57 - 64
  • [46] Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy
    Grills, Inga S.
    Hugo, Geoffrey
    Kestfn, Larry L.
    Galerani, Ana Paula
    Chao, K. Kenneth
    Wloch, Jennifer
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1045 - 1056
  • [47] CORRECTION STRATEGIES FOR CONE-BEAM CT GUIDED RADIOTHERAPY
    Remeijer, P.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S141 - S142
  • [48] Clinical implementation of cone-beam CT guided radiotherapy
    van Herk, M
    Jaffray, D
    Remeijer, P
    Sonke, JJ
    Lebesque, JV
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S17 - S17
  • [49] Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment
    Paluska, Petr
    Hanus, Josef
    Sefrova, Jana
    Rouskova, Lucie
    Grepl, Jakub
    Jansa, Jan
    Kasaova, Linda
    Hodek, Miroslav
    Zouhar, Milan
    Vosmik, Milan
    Petera, Jiri
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2012, 17 (03) : 134 - 140
  • [50] Image-guided radiotherapy for prostate cancer with cone beam CT: dosimetric effects of imaging frequency and PTV margin
    Ariyaratne, Hemal
    Chesham, Hayley
    Pettingell, John
    Alonzi, Roberto
    RADIOTHERAPY AND ONCOLOGY, 2016, 121 (01) : 103 - 108