Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors

被引:117
|
作者
Guckenberger, Matthias [1 ]
Meyer, Juergen [1 ]
Wilbert, Juergen [1 ]
Richter, Anne [1 ]
Baier, Kurt [1 ]
Mueller, Gerd [1 ]
Flentje, Michael [1 ]
机构
[1] Univ Wurzburg, Dept Radiat Oncol, D-97080 Wurzburg, Germany
关键词
image-guided radiotherapy (IGRT); stereotactic body radiotherapy (SBRT); intra-fractional errors; cone-beam CT;
D O I
10.1016/j.radonc.2007.01.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Intra-fractional variability of tumor position and breathing motion was evaluated in cone-beam CT (CB-CT) based image-guided radiotherapy (IGRT) of pulmonary tumors. Materials and methods: Twenty-four patients (27 lesions: prim. NSCLC n = 6; metastases n = 21) were treated with stereotactic body radiotherapy (SBRT) (one to eight fractions). Prior to every treatment fraction (n = 66) and immediately after treatment a CB-CT was acquired. Patient motion, absolute drift and drift of the tumor relative to the bony anatomy were measured. Tumor motion was investigated based on the density distribution in the CB-CT. Results: Absolute intra-fractional drift (31) vector) of the tumor position was 2.8 mm 1.6 mm (mean +/- SD), maximum 7.2 mm. Poor correlation between patient motion and absolute tumor drift was observed. Changes of the tumor position due to patient motion and due to drifts independently from the bony anatomy were of similar magnitude with 2.1 mm +/- 1.4 mm and 2.3 mm +/- 1.6 mm, respectively. No systematic increase or decrease of breathing motion was seen. The intra-fractional change of breathing motion was more than 2 mm and 3 mm in 39% and 16%, respectively. Conclusion: Intra-fractional tumor position and breathing motion were stable. In IGRT of pulmonary tumors we suggest an ITV-to-PTV margin of 5 mm to compensate intra-fractional changes. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [1] Clinical introduction of image-guided radiotherapy, IGRT with cone beam CT
    Sorcini, B
    Odh, R
    Näfstadius, P
    Näslund, I
    Wersäll, P
    Tilikidis, A
    Severin, AC
    Isoz, A
    Fjällman, P
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S103 - S103
  • [2] Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CT
    Zucca, Sergio
    Carau, Barbara
    Solla, Ignazio
    Garibaldi, Elisabetta
    Farace, Paolo
    Lay, Giancarlo
    Meleddu, Gianfranco
    Gabriele, Pietro
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 473 - 478
  • [3] Hypofractionated online image-guided radiotherapy (IGRT) via cone-beam CT (CBCT) for prostate cancer
    Kestin, L.
    Yan, D.
    Ghilezan, M.
    Wu, Q.
    Wloch, J.
    Vicini, F.
    Martinez, A.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S169 - S169
  • [4] Cone-beam CT (CBCT) image-guided radiotherapy (IGRT) significantly reduces margins required for stereotactic
    Grills, I.
    Kestin, L.
    Yan, D.
    Chao, K.
    Wloch, J.
    Hugo, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S62 - S62
  • [5] An Optimized Protocol for Using Small Field MV Cone-Beam CT Imaging in Image-Guided Radiotherapy (IGRT)
    Yembi-Goma, G.
    Lu, L.
    Li, K.
    Wang, J.
    Zhang, H.
    Martin, D.
    Gupta, N.
    MEDICAL PHYSICS, 2009, 36 (06) : 2478 - +
  • [6] IMAGE-GUIDED RADIOTHERAPY (IGRT) BY CONE-BEAM CT (CBCT) IN PROSTATE CANCER PATIENTS: DAILY OR WEEKLY VERIFICATION?
    Ferrer Gonzalez, F.
    Ballivy, O.
    Sancho, I.
    Boladeras Inglada, A. M.
    Leon, P. R.
    Gutierrez, C.
    Martinez, E.
    Gonzalez Imhoff, M. N.
    Prat, X.
    Pera, J.
    Guedea, F.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S404 - S405
  • [7] Precision of three dimensional image-guided radiotherapy (IGRT) using cone-beam CT and hexapod in clinical practice
    Guckenberge, M.
    Wilbert, J.
    Richter, A.
    Baier, K.
    Meyer, J.
    Sauer, O.
    Flentje, M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S146 - S146
  • [8] Cone-beam CT: Applications in image-guided external beam radiotherapy and brachytherapy
    Jaffray, DA
    Siewerdsen, JH
    Edmundson, GE
    Wong, JW
    Martinez, A
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2044 - 2044
  • [9] Towards optimization of megavoltage cone-beam CT for image-guided radiotherapy
    Pang, G
    O'Brien, P
    Mei, X
    Tambasco, M
    Yeboah, C
    Beachey, D
    Rowlands, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S623 - S623
  • [10] Patient dose in KV cone-beam CT image-guided radiotherapy
    Islam, M
    Purdie, T
    Moseley, D
    Alasti, H
    Norrlinger, B
    Sharpe, M
    Siewerdsen, J
    Jaffray, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1830 - 1830