Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors

被引:117
|
作者
Guckenberger, Matthias [1 ]
Meyer, Juergen [1 ]
Wilbert, Juergen [1 ]
Richter, Anne [1 ]
Baier, Kurt [1 ]
Mueller, Gerd [1 ]
Flentje, Michael [1 ]
机构
[1] Univ Wurzburg, Dept Radiat Oncol, D-97080 Wurzburg, Germany
关键词
image-guided radiotherapy (IGRT); stereotactic body radiotherapy (SBRT); intra-fractional errors; cone-beam CT;
D O I
10.1016/j.radonc.2007.01.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Intra-fractional variability of tumor position and breathing motion was evaluated in cone-beam CT (CB-CT) based image-guided radiotherapy (IGRT) of pulmonary tumors. Materials and methods: Twenty-four patients (27 lesions: prim. NSCLC n = 6; metastases n = 21) were treated with stereotactic body radiotherapy (SBRT) (one to eight fractions). Prior to every treatment fraction (n = 66) and immediately after treatment a CB-CT was acquired. Patient motion, absolute drift and drift of the tumor relative to the bony anatomy were measured. Tumor motion was investigated based on the density distribution in the CB-CT. Results: Absolute intra-fractional drift (31) vector) of the tumor position was 2.8 mm 1.6 mm (mean +/- SD), maximum 7.2 mm. Poor correlation between patient motion and absolute tumor drift was observed. Changes of the tumor position due to patient motion and due to drifts independently from the bony anatomy were of similar magnitude with 2.1 mm +/- 1.4 mm and 2.3 mm +/- 1.6 mm, respectively. No systematic increase or decrease of breathing motion was seen. The intra-fractional change of breathing motion was more than 2 mm and 3 mm in 39% and 16%, respectively. Conclusion: Intra-fractional tumor position and breathing motion were stable. In IGRT of pulmonary tumors we suggest an ITV-to-PTV margin of 5 mm to compensate intra-fractional changes. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [41] Comparison of Acuity Cone-Beam CT Based Image Guided HDR with the Conventional CT-Simulator Based Image-Guided HDR
    Lu, L.
    Gupta, N.
    Martin, D.
    Hattie, T.
    Carpenter, A.
    Weldon, M.
    Woollard, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S909 - S909
  • [42] Inter-breath-hold motion in gated cone-beam CT introducing uncertainties in image-guided radiotherapy for breath-hold treatment
    Zhuang, Tingliang
    Magnelli, Anthony
    Liu, Han
    Qi, Peng
    Djemil, Toufik
    Stephans, Kevin
    Videtic, Gregory
    Xia, Ping
    JOURNAL OF RADIATION ONCOLOGY, 2014, 3 (03) : 321 - 330
  • [43] Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors
    Jensen, Nikolaj K. G.
    Stewart, Errol
    Lock, Michael
    Fisher, Barbara
    Kozak, Roman
    Chen, Jeff
    Lee, Ting-Yim
    Wong, Eugene
    MEDICAL PHYSICS, 2014, 41 (05)
  • [44] Intraoperative cone-beam CT for image-guided tibial plateau fracture reduction
    Khoury, A.
    Siewerdsen, J. H.
    Whyne, C. M.
    Daly, M. J.
    Kreder, H. J.
    Moseley, D. J.
    Jaffray, D. A.
    COMPUTER AIDED SURGERY, 2007, 12 (04) : 195 - 207
  • [45] Fusion of Intraoperative Cone-Beam CT and Endoscopic Video for Image-Guided Procedures
    Daly, M. J.
    Chan, H.
    Prisman, E.
    Vescan, A.
    Nithiananthan, S.
    Qiu, J.
    Weersink, R.
    Irish, J. C.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [46] Kilo-voltage cone-beam CT for image-guided radiation therapy
    Sonke, JJ
    Remeijer, P
    Betgen, A
    Lebesque, J
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S70 - S70
  • [47] Feasability Study of Low-dose Intra-operative Cone-beam CT for Image-guided Surgery
    Han, Xiao
    Shi, Shuanghe
    Bian, Junguo
    Helm, Patrick
    Sidky, Emil Y.
    Pan, Xiaochuan
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [48] Ultrasound versus Cone-beam CT image-guided radiotherapy for prostate and post-prostatectomy pretreatment localization
    Fargier-Voiron, Marie
    Presles, Benoit
    Pommier, Pascal
    Munoz, Alexandre
    Rit, Simon
    Sarrut, David
    Biston, Marie-Claude
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 997 - 1004
  • [49] Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy
    Grills, Inga S.
    Hugo, Geoffrey
    Kestfn, Larry L.
    Galerani, Ana Paula
    Chao, K. Kenneth
    Wloch, Jennifer
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1045 - 1056
  • [50] Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CTBildgeführte Radiotherapie der Prostata mit Megavolt-Cone-Beam-CT
    Sergio Zucca
    Barbara Carau
    Ignazio Solla
    Elisabetta Garibaldi
    Paolo Farace
    Giancarlo Lay
    Gianfranco Meleddu
    Pietro Gabriele
    Strahlentherapie und Onkologie, 2011, 187 (8) : 473 - 478