Analysis of sensitivity and optical path-length in non-invasive measurement of glucose with near infrared spectroscopy

被引:4
|
作者
Luo, YH [1 ]
Liu, R [1 ]
Chen, WL [1 ]
Cui, HX [1 ]
Xu, KX [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
关键词
glucose monitoring; ratio of effective photons; sensitivity; source-detector separation; Monte Carlo;
D O I
10.1117/12.596172
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Non-invasive glucose monitoring with optical methods has obtained increasing interest, in that the methods have shown great benefit for diabetes. Nevertheless, low sensitivity and signal to noise ratio (ratio of effective photons) are two major difficulties in non-invasively NIR spectral monitoring of blood glucose concentration. Designing the optical probe properly is one of the effective ways to improve measuring sensitivity and ratio of effective photons. In this paper, definition about ratio of effective photons in measurement of glucose is introduced. And then effect of glucose on optical properties of human skin is analyzed, based on this, two kind of sensitivities for diffuse reflectance, namely sensitivity to absorption and that to scattering, is derived. To investigate the ratio of effective photons and sensitivities, Monte Carlo simulations have been performed on a three-layered media with optical parameters similar to those of human skin. The results have shown that (1) high ratio of effective photons, even as high as 60%, can be obtained by choosing proper the separation between source and detector; (2) sensitivity of diffuse reflectance to absorption and scattering has different dependence on source-detector separation, which enables one can have different options by making use of different effect from glucose level changing. In the end, some suggestions have been put forward to improve precision of measurement of blood glucose.
引用
收藏
页码:205 / 214
页数:10
相关论文
共 50 条
  • [21] Extraction of glucose information in blood glucose measurement by non-invasive near-infrared spectra
    Liu, R
    Chen, WL
    Gu, XY
    Luo, YH
    Xu, KX
    OPTICAL DIAGNOSTICS AND SENSING V, 2005, 5702 : 30 - 38
  • [22] Effect of Path-Length Variations on PLSR Calibration Model in Noninvasive Measurement of Blood Glucose by Mid-Infrared Spectroscopy
    Wang Dong-min
    Lu Qi-peng
    Ding Hai-quan
    Huang Fu-rong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (04) : 930 - 933
  • [23] Research on the background correction in the non-invasive sensing of glucose by near-infrared spectroscopy
    Liu Rong
    Gu Xiao-yu
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (08) : 1772 - 1775
  • [24] A CMOS Sensor for Measurement of Cerebral Optical Coefficients Using Non-Invasive Frequency Domain Near Infrared Spectroscopy
    Sthalekar, Chirag Chaitanya
    Koomson, Valencia Joyner
    IEEE SENSORS JOURNAL, 2013, 13 (09) : 3166 - 3174
  • [25] Application of genetic algorithms in fundamental study of non-invasive measurement of human blood glucose concentration with near infrared spectroscopy
    Wang, H
    Li, QB
    Liu, ZY
    Xu, KX
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (07) : 779 - 783
  • [26] Preliminary study of mechanism of non-invasive blood glucose measurement based on near-infrared diffuse reflectance spectroscopy
    Chen, WL
    Liu, R
    Luo, YH
    Han, YH
    Xu, KX
    Complex Dynamics and Fluctuations in Biomedical Photonics II, 2005, 5696 : 91 - 100
  • [27] Non-Invasive Blood Glucose Measurement Using Near Infra-Red Spectroscopy
    Priyoti, Anika Tabassum
    Jim, Salman Jubair
    Hossain, Sushmit
    Mahmud, Shafkat
    Salvin, Sujana
    Bhattacharjee, Arnab
    PROCEEDINGS OF 2019 IEEE R10 HUMANITARIAN TECHNOLOGY CONFERENCE (IEEE R10 HTC 2019), 2019, : 1 - 4
  • [28] NIR Photoacoustic Spectroscopy for Non-Invasive Glucose Measurement
    Pai, Praful P.
    Sanki, Pradyut Kumar
    De, Arijit
    Banerjee, Swapna
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 7978 - 7981
  • [29] In vivo measurement of the local optical properties of tissue by use of differential path-length spectroscopy
    Amelink, A
    Sterenborg, HJCM
    Bard, MPL
    Burgers, SA
    OPTICS LETTERS, 2004, 29 (10) : 1087 - 1089
  • [30] Feasibility research on non-invasive analysis of Tanreqing injection with near infrared spectroscopy
    Li, Wenlong
    Cheng, Zhiwei
    Wang, Yuefei
    Qu, Haibin
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2012, 20 (06) : 667 - 674