NIR Photoacoustic Spectroscopy for Non-Invasive Glucose Measurement

被引:0
|
作者
Pai, Praful P. [1 ]
Sanki, Pradyut Kumar [1 ]
De, Arijit [1 ]
Banerjee, Swapna [1 ]
机构
[1] Indian Inst Technol, Dept Elect & Elect Commun Engn, Kharagpur 721302, W Bengal, India
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of near infra red (NIR) photoacoustic spectroscopy (PAS) for continuous non-invasive glucose measurement is outlined in the paper. A photoacoustic (PA) measurement apparatus was constructed and PA measurements were made on glucose solutions at multiple NIR excitation wavelengths. A variety of time and frequency domain features, including amplitude and area based features, were extracted from the PA measurements. These features were observed to be proportional to the glucose concentration of the sample. PA measurements from samples of whole blood at different glucose concentrations showed similar results. Subsequently, in vivo PA measurements made on a cohort of 30 volunteers were calibrated using a quadratic fit, and the results were compared to reference glucose concentrations made using a regular blood glucose meter. A comparison of 196 measurement pairs of predicted and reference glucose concentrations using a Clarke Error Grid gave a point distribution of 87.24% and 12.76% over zones A and B of the grid, with no measurement pairs falling in unacceptable zones C-E of the error grid. The predicted measurements had a mean absolute difference (MAD) of 12.57 +/- 13.90 mg/dl and a mean absolute relative difference (MARD) of 9.61% +/- 10.55%. This is an improvement over previous results obtained using PAS and other non-invasive techniques, validating the potential of PAS for continuous non-invasive glucose monitoring.
引用
收藏
页码:7978 / 7981
页数:4
相关论文
共 50 条
  • [1] Instrumental Requirements for Non-Invasive Blood Glucose Measurement Using NIR Spectroscopy
    Hidenobu Arimoto
    Masatoshi Tarumi
    Yukio Yamada
    [J]. Optical Review, 2003, 10 : 161 - 165
  • [2] Instrumental requirements for non-invasive blood glucose measurement using NIR spectroscopy
    Arimoto, H
    Tarumi, M
    Yamada, Y
    [J]. OPTICAL REVIEW, 2003, 10 (03) : 161 - 165
  • [3] Research on Non-invasive Glucose Concentration Measurement by NIR Transmission
    Li, Xiaoli
    Li, Chengwei
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATIONS (ICCC), 2015, : 223 - 228
  • [4] INFLUENCE OF THE STRATUM CORNEUM THICKNESS ON NON-INVASIVE GLUCOSE MEASUREMENT BY MIDDLE INFRARED PHOTOACOUSTIC SPECTROSCOPY
    von Lilienfeld-Toal, H.
    Lieblein, T.
    Bauer, A.
    Hertzberg, O.
    Pleitez, M.
    Maentele, W.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A80 - A80
  • [5] Differential Continuous Wave Photoacoustic Spectroscopy for Non-Invasive Glucose Monitoring
    Tanaka, Yujiro
    Tajima, Takuro
    Seyama, Michiko
    Waki, Kayo
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (08) : 4453 - 4458
  • [6] Non-invasive blood glucose in vivo detection based on photoacoustic spectroscopy
    Lü, Peng-Fei
    Lu, Zhi-Qian
    He, Qiao-Zhi
    Wang, Qian
    Zhao, Hui
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (06): : 1301 - 1308
  • [7] Non-Invasive Blood Glucose Monitoring Device Using Photoacoustic Spectroscopy
    Jahana, Takahito
    Higa, Hiroki
    [J]. 2020 5TH INTERNATIONAL CONFERENCE ON INTELLIGENT INFORMATICS AND BIOMEDICAL SCIENCES (ICIIBMS 2020), 2020, : 85 - 88
  • [8] Photoacoustic depth profiling of a skin model for non-invasive glucose measurement
    Wadamori, Naoki
    Shinohara, Ryou
    Ishihara, Yasutoshi
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5644 - 5647
  • [9] Photoacoustic Sensor Using Silicon Piezoresistor for Non-Invasive Measurement of Glucose
    Noda, Kentaro
    Tsukagoshi, Takuya
    Shimoyama, Isao
    [J]. IEEJ Transactions on Sensors and Micromachines, 2023, 143 (07) : 171 - 175
  • [10] A non-invasive photoacoustic and ultrasonic method for the measurement of glucose solution concentration
    Zhao, Siwei
    Tao, Wei
    He, Qiaozhi
    Zhao, Hui
    Cao, Wenwu
    [J]. AIP ADVANCES, 2017, 7 (03)