Instrumental requirements for non-invasive blood glucose measurement using NIR spectroscopy

被引:13
|
作者
Arimoto, H
Tarumi, M
Yamada, Y
机构
[1] Natl Inst Adv Ind Sci & Technol, Inst Human Sci & Biomed Engn, Tsukuba, Ibaraki 3058564, Japan
[2] Nikkiso Co Ltd, Haibara, Sizuoka 4210496, Japan
[3] Univ Electrocommun, Dept Mech Engn & Intelligent Syst, Chofu, Tokyo 1828585, Japan
关键词
blood glucose measurement; non-invasive measurement; Monte Carlo simulation; NIR spectroscopy; scattering;
D O I
10.1007/s10043-003-0161-1
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The magnitude of spectral change in blood glucose measurements with diffuse reflectance spectroscopy is investigated. Spectral change is estimated by simulation of light propagation in skin tissue and measurements of absorbance spectra of aqueous glucose solution. Required sensitivity of spectrophotometers for monitoring change in the blood glucose concentration as small as 10 mg/dL has been obtained using the estimated change in the absorbance spectrum and mean pathlength of light in tissue.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 50 条
  • [1] Instrumental Requirements for Non-Invasive Blood Glucose Measurement Using NIR Spectroscopy
    Hidenobu Arimoto
    Masatoshi Tarumi
    Yukio Yamada
    Optical Review, 2003, 10 : 161 - 165
  • [2] NIR Photoacoustic Spectroscopy for Non-Invasive Glucose Measurement
    Pai, Praful P.
    Sanki, Pradyut Kumar
    De, Arijit
    Banerjee, Swapna
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 7978 - 7981
  • [3] Non-invasive Blood Glucose Measurement Using Transmission Spectroscopy
    Khawam, Yahya
    Ali, Muddassar
    Shazada, Haris
    Kanan, Sofian
    Nashash, Hasan
    2013 FIRST INTERNATIONAL CONFERENCE ON COMMUNICATIONS SIGNAL PROCESSING, AND THEIR APPLICATIONS (ICCSPA'13), 2013,
  • [4] A precise non-invasive blood glucose measurement system using NIR spectroscopy and Huber's regression model
    Jain, Prateek
    Maddila, Ravi
    Joshi, Amit M.
    OPTICAL AND QUANTUM ELECTRONICS, 2019, 51 (02)
  • [5] A precise non-invasive blood glucose measurement system using NIR spectroscopy and Huber’s regression model
    Prateek Jain
    Ravi Maddila
    Amit M. Joshi
    Optical and Quantum Electronics, 2019, 51
  • [6] Development of Portable Non-invasive Blood Glucose Measuring Device Using NIR Spectroscopy
    Asekar, Megha S.
    PROCEEDINGS OF THE 2018 SECOND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL SYSTEMS (ICICCS), 2018, : 572 - 575
  • [7] A Survey on Non-Invasive Blood Glucose Monitoring Using NIR
    Menon, K. A. Unnikrishna
    Hemachandran, Deepak
    Abhishek, T. K.
    2013 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), 2013, : 1069 - 1072
  • [8] Influence of cholesterol on non-invasive blood glucose sensing studied with NIR spectroscopy
    Jiang, Jingying
    Zhang, Lingling
    Gong, Qiliang
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VIII, 2011, 7898
  • [9] Development of NIR Spectroscopy Based Non-invasive Blood Glucose Measuring Device
    Asekar, Megha Shyam
    Sonawane, D. N.
    2018 4TH INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2018,
  • [10] Non-Invasive Glucose Measurement Using Spectrography In Near Infrared (NIR)
    Castro-Pimentel, Luis
    Tellez-Anguiano, Adriana
    Guerra-Alvarado, Osmar
    Hernandez-Franco, Kevin
    IEEE LATIN AMERICA TRANSACTIONS, 2019, 17 (11) : 1754 - 1760