Analysis of sensitivity and optical path-length in non-invasive measurement of glucose with near infrared spectroscopy

被引:4
|
作者
Luo, YH [1 ]
Liu, R [1 ]
Chen, WL [1 ]
Cui, HX [1 ]
Xu, KX [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
关键词
glucose monitoring; ratio of effective photons; sensitivity; source-detector separation; Monte Carlo;
D O I
10.1117/12.596172
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Non-invasive glucose monitoring with optical methods has obtained increasing interest, in that the methods have shown great benefit for diabetes. Nevertheless, low sensitivity and signal to noise ratio (ratio of effective photons) are two major difficulties in non-invasively NIR spectral monitoring of blood glucose concentration. Designing the optical probe properly is one of the effective ways to improve measuring sensitivity and ratio of effective photons. In this paper, definition about ratio of effective photons in measurement of glucose is introduced. And then effect of glucose on optical properties of human skin is analyzed, based on this, two kind of sensitivities for diffuse reflectance, namely sensitivity to absorption and that to scattering, is derived. To investigate the ratio of effective photons and sensitivities, Monte Carlo simulations have been performed on a three-layered media with optical parameters similar to those of human skin. The results have shown that (1) high ratio of effective photons, even as high as 60%, can be obtained by choosing proper the separation between source and detector; (2) sensitivity of diffuse reflectance to absorption and scattering has different dependence on source-detector separation, which enables one can have different options by making use of different effect from glucose level changing. In the end, some suggestions have been put forward to improve precision of measurement of blood glucose.
引用
收藏
页码:205 / 214
页数:10
相关论文
共 50 条
  • [41] UTILIZATION OF FUNCTIONAL NEAR INFRARED SPECTROSCOPY FOR NON-INVASIVE EVALUATION
    Halim, A. A. A.
    Laili, M. H.
    Aziz, N. A.
    Laili, A. R.
    Salikin, M. S.
    Rusop, M.
    INTERNATIONAL CONFERENCE ON NANO-ELECTRONIC TECHNOLOGY DEVICES AND MATERIALS (IC-NET 2015), 2016, 1733
  • [42] Functional near-infrared spectroscopy in non-invasive neuromodulation
    Huo, Congcong
    Xu, Gongcheng
    Xie, Hui
    Chen, Tiandi
    Shao, Guangjian
    Wang, Jue
    Li, Wenhao
    Wang, Daifa
    Li, Zengyong
    NEURAL REGENERATION RESEARCH, 2024, 19 (07) : 1517 - 1522
  • [43] Non-invasive monitoring of dough mixing by near infrared spectroscopy
    Wesley, IJ
    Larsen, N
    Osborne, BG
    Skerritt, JH
    JOURNAL OF CEREAL SCIENCE, 1998, 27 (01) : 61 - 69
  • [44] Optical path-length spectroscopy of wave propagation in random media
    Popescu, G
    Dogariu, A
    OPTICS LETTERS, 1999, 24 (07) : 442 - 444
  • [45] Determination of the reference position in the near-infrared non-invasive blood glucose measurement in vivo
    Han, Guang
    Liu, Jin
    Liu, Rong
    Xu, Kexin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024
  • [46] Application of O-PLS in fundamental study of non-invasive measurement of human blood glucose concentration with near infrared spectroscopy
    Lü, LN
    Liu, R
    Zhou, DW
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (12) : 1950 - 1954
  • [47] INFLUENCE OF THE STRATUM CORNEUM THICKNESS ON NON-INVASIVE GLUCOSE MEASUREMENT BY MIDDLE INFRARED PHOTOACOUSTIC SPECTROSCOPY
    von Lilienfeld-Toal, H.
    Lieblein, T.
    Bauer, A.
    Hertzberg, O.
    Pleitez, M.
    Maentele, W.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A80 - A80
  • [48] Non-Invasive Measurement of Water Content in Engine Lubricant Using Visible and Near Infrared Spectroscopy
    Zhang Yu
    Jiang Lu-lu
    Wu Di
    Tan Li-hong
    He Yong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (08) : 2111 - 2114
  • [49] Feasibility of non-invasive measurement of tissue pH using near-infrared reflectance spectroscopy
    Soller, BR
    Micheels, RH
    Coen, J
    Parikh, B
    Chu, L
    Hsi, C
    JOURNAL OF CLINICAL MONITORING, 1996, 12 (05): : 387 - 395
  • [50] Feasibility of non-invasive measurement of tissue pH using near-infrared reflectance spectroscopy
    Center for Advanced Clinical Technology, Worcester, MA 01655, United States
    不详
    不详
    不详
    J. CLIN. MONIT., 5 (387-395):