Transducer modeling for accurate acoustic simulations of transcranial focused ultrasound stimulation

被引:24
|
作者
Pasquinelli, Cristina [1 ,2 ,3 ]
Montanaro, Hazael [3 ,4 ,5 ]
Lee, Hyunjoo J. [6 ]
Hanson, Lars G. [1 ,2 ]
Kim, Hyungkook [6 ]
Kuster, Niels [4 ,5 ]
Siebner, Hartwig R. [1 ,7 ]
Neufeld, Esra [4 ]
Thielscher, Axel [1 ,2 ]
机构
[1] Copenhagen Univ Hosp Hvidovre, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, Hvidovre, Denmark
[2] Tech Univ Denmark, Dept Hlth Technol, Ctr Magnet Resonance, Lyngby, Denmark
[3] Fdn Res Informat Technol Soc ITIS, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[5] Korea Adv Inst Sci & Technol, Sch Elect Engn, Daejeon, South Korea
[6] Copenhagen Univ Hosp Bispebjerg, Dept Neurol, Copenhagen, Denmark
[7] Univ Copenhagen, Inst Clin Med, Fac Hlth & Med Sci, Copenhagen, Denmark
关键词
transcranial focused ultrasound stimulation; single element focused transducer; finite difference time domain; computational dosimetry; gamma method; FREQUENCY-DEPENDENCE; SPEED; SOUND; TRANSMISSION; ATTENUATION;
D O I
10.1088/1741-2552/ab98dc
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Low-intensity transcranial ultrasound stimulation (TUS) is emerging as a non-invasive brain stimulation technique with superior spatial resolution and the ability to reach deep brain areas. Medical image-based computational modeling could be an important tool for individualized TUS dose control and targeting optimization, but requires further validation. This study aims to assess the impact of the transducer model on the accuracy of the simulations.Approach. Using hydrophone measurements, the acoustic beam of a single-element focused transducer (SEFT) with a flat piezoelectric disc and an acoustic lens was characterized. The acoustic beam was assessed in a homogeneous water bath and after transmission through obstacles (3D-printed shapes and skull samples). The acoustic simulations employed the finite-difference time-domain method and were informed by computed tomography (CT) images of the obstacles. Transducer models of varying complexity were tested representing the SEFT either as a surface boundary condition with variable curvature or also accounting for its internal geometry. In addition, a back-propagated pressure distribution from the first measurement plane was used as source model. The simulations and measurements were quantitatively compared using key metrics for peak location, focus size, intensity and spatial distribution.Main results. While a surface boundary with an adapted, 'effective' curvature radius based on the specifications given by the manufacturer could reproduce the measured focus location and size in a homogeneous water bath, it regularly failed to accurately predict the beam after obstacle transmission. In contrast, models that were based on a one-time calibration to the homogeneous water bath measurements performed substantially better in all cases with obstacles. For one of the 3D-printed obstacles, the simulated intensities deviated substantially from the measured ones, irrespective of the transducer model. We attribute this finding to a standing wave effect, and further studies should clarify its relevance for accurate simulations of skull transmission.Significance. Validated transducer models are important to ensure accurate simulations of the acoustic beam of SEFTs, in particular in the presence of obstacles such as the skull.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Computational modeling of a single-element transcranial focused ultrasound transducer for subthalamic nucleus stimulation
    Samoudi, Mohammed A.
    Van Renterghem, Timothy
    Botteldooren, Dick
    JOURNAL OF NEURAL ENGINEERING, 2019, 16 (02)
  • [2] Pitfalls in acoustic transducer modeling for focused ultrasound (FUS)
    Pasquinelli, C.
    Montanaro, H.
    Neufeld, E.
    Poni, R.
    Kuster, N.
    Thielscher, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (05) : 501 - 501
  • [3] Ultrasound Transducer and Amplifier Design in Transcranial Ultrasound Stimulation System
    Shi, Xun
    Zhang, Shuai
    Wang, Zhuo
    Xu, Guizhi
    2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2016, : 828 - 830
  • [4] Simultaneous acoustic stimulation of human primary and secondary somatosensory cortices using transcranial focused ultrasound
    Lee, Wonhye
    Chung, Yong An
    Jung, Yujin
    Song, In-Uk
    Yoo, Seung-Schik
    BMC NEUROSCIENCE, 2016, 17
  • [5] Simultaneous acoustic stimulation of human primary and secondary somatosensory cortices using transcranial focused ultrasound
    Wonhye Lee
    Yong An Chung
    Yujin Jung
    In-Uk Song
    Seung-Schik Yoo
    BMC Neuroscience, 17
  • [6] Transcranial Focused Ultrasound Stimulation of Periaqueductal Gray for Analgesia
    Zhang Tao
    Wang Zhen
    Liang, Huageng
    Wu, Zhengjie
    Li, Jiapu
    Ou-Yang Jun
    Yang, Xiaofei
    Peng Yuan Bo
    Zhu, Benpeng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (10) : 3155 - 3162
  • [7] Transcranial focused ultrasound stimulation with high spatial resolution
    Kim, Seongyeon
    Jo, Yehhyun
    Kook, Geon
    Pasquinelli, Cristina
    Kim, Hyunggug
    Kim, Kipom
    Hoe, Hyang-Sook
    Choe, Youngshik
    Rhim, Hyewhon
    Thielscher, Axel
    Kim, Jeongyeon
    Lee, Hyunjoo Jenny
    BRAIN STIMULATION, 2021, 14 (02) : 290 - 300
  • [8] A transducer positioning method for transcranial focused ultrasound treatment of brain tumors
    Gao, Penghao
    Sun, Yue
    Zhang, Gongsen
    Li, Chunsheng
    Wang, Linlin
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [9] Skull Impact on the Ultrasound Beam Profile of Transcranial Focused Ultrasound Stimulation
    Tsai, Pin-Chien
    Gougheri, Hesam Sadeghi
    Kiani, Mehdi
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 5188 - 5191
  • [10] The impact of CT image parameters and skull heterogeneity modeling on the accuracy of transcranial focused ultrasound simulations
    Montanaro, Hazael
    Pasquinelli, Cristina
    Lee, Hyunjoo J.
    Kim, Hyunggug
    Siebner, Hartwig R.
    Kuster, Niels
    Thielscher, Axel
    Neufeld, Esra
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (04)