Experimental study on the operating characteristics of a display refrigerator phasing out R134a to R1234ze(E) and its binary blends

被引:11
|
作者
Ramirez-Hernandez, H. G. [1 ]
Morales-Fuentes, A. [1 ]
Sanchez-Cruz, F. A. [1 ]
Mendez-Diaz, S. [1 ]
Garcia-Lara, H. D. [1 ]
Martinez-Martinez, S. [1 ]
机构
[1] Univ Autonoma Nuevo Leon, Fac Ingn Mecan & Elect FIME, Lab Res & Innovat Energy Technol LIITE, Av Univ S-N,Ciudad Univ, San Nicolas De Los Garza 66455, Nuevo Leon, Mexico
关键词
R1234ze(E)-R134a blends; Drop-in refrigerants; Vertical display refrigerator; Refrigerant charge; ENERGY PERFORMANCE EVALUATION; DROP-IN; R1234YF; REPLACEMENTS; R450A; ALTERNATIVES; R-134A;
D O I
10.1016/j.ijrefrig.2022.03.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
In recent years, the refrigerant drop-in replacement of R134a has been mainly motivated due to environmental issues. This study aims to experimentally compare the operating characteristics in light commercial refrigeration using a display refrigerator when R134a is substituted with pure R1234ze(E) and R1234ze(E)-R134a blends. The refrigerants R450A (R1234ze(E)-R134a 58-42wt% blend), and R1234ze(E)-R134a 90-10wt% blend with GWP of 547 and 150 respectively are evaluated. The adequate refrigerant charge is determined, and the performance evaluation is carried on under controlled ambient temperatures of 24, 32, and 40 degrees C. The results show a slightly reduced refrigerant charge for higher operating temperatures. Pure R1234ze(E) and its mixtures with R134a are a suitable short-term solution in light commercial refrigeration, satisfying ambient regulations with the maximum electric energy input increase by 6% under ambient temperature of 40 degrees C. Its reduced operating pressure of 36% at the condenser might result of interest for some applications.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [31] Experimental study on R1234yf/R134a mixture (R513A) as R134a replacement in a domestic refrigerator
    Yang, Meng
    Zhang, Hua
    Meng, Zhaofeng
    Qin, Yanbin
    APPLIED THERMAL ENGINEERING, 2019, 146 : 540 - 547
  • [32] Evaporation of R1234yf, R1234ze(E) and R1234ze(Z) on Cu surface: A molecular dynamics study
    Deng, Xinxin
    Xiao, Yitian
    Li, Qibin
    He, Chao
    Wang, Shukun
    JOURNAL OF MOLECULAR LIQUIDS, 2021, 344
  • [33] Drop-in energy performance evaluation of R1234yf and R1234ze(E) in a vapor compression system as R134a replacements
    Mota-Babiloni, Adrian
    Navarro-Esbri, Joaquin
    Barragan, Angel
    Moles, Francisco
    Peris, Bernardo
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 259 - 265
  • [34] Comparative evaluation of R1234yf, R1234ze(E) and R450A as alternatives to R134a in a variable speed reciprocating compressor
    Mendoza-Miranda, J. M.
    Mota-Babiloni, A.
    Ramirez-Minguela, J. J.
    Munoz-Carpio, V. D.
    Carrera-Rodriguez, M.
    Navarro-Esbri, J.
    Salazar-Hernandez, C.
    ENERGY, 2016, 114 : 753 - 766
  • [35] High heat flux flow boiling of R1234yf, R1234ze(E) and R134a in high aspect ratio microchannels
    Criscuolo, Gennaro
    Markussen, Wiebke Brix
    Meyer, Knud Erik
    Kaern, Martin Ryhl
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 186
  • [36] R134a and R1234ze(E) liquid and flow boiling heat transfer in a high porosity copper foam
    Mancin, Simone
    Diani, Andrea
    Doretti, Luca
    Rossetto, Luisa
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 74 : 77 - 87
  • [37] 微细通道内R1234ze(E)和R134a冷凝特性的数值模拟
    顾昕
    文键
    张星
    王斯民
    厉彦忠
    高校化学工程学报, 2020, 34 (01) : 96 - 103
  • [38] Comparison of the New Refrigerant R1336mzz(E) with R1234ze(E) as an Alternative to R134a for Use in Heat Pumps
    Drofenik, Jan
    Urbancl, Danijela
    Goricanec, Darko
    PROCESSES, 2022, 10 (02)
  • [39] First experimental results of the use of R1234yf and R1234ze(E) as drop-in substitutes for R134a in a water-to-water heat pump
    Molinaroli, L.
    Lucchini, A.
    Colombo, L. P. M.
    Bocchinfuso, F.
    37TH UIT HEAT TRANSFER CONFERENCE, 2020, 1599
  • [40] Condensation heat transfer of R134a, R1234ze(E) and R290 on horizontal plain and enhanced titanium tubes
    Ji, Wen-Tao
    Chong, Guo-Hun
    Zhao, Chuang-Yao
    Zhang, Hu
    Tao, Wen-Quan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 93 : 259 - 268