Experimental study on the operating characteristics of a display refrigerator phasing out R134a to R1234ze(E) and its binary blends

被引:11
|
作者
Ramirez-Hernandez, H. G. [1 ]
Morales-Fuentes, A. [1 ]
Sanchez-Cruz, F. A. [1 ]
Mendez-Diaz, S. [1 ]
Garcia-Lara, H. D. [1 ]
Martinez-Martinez, S. [1 ]
机构
[1] Univ Autonoma Nuevo Leon, Fac Ingn Mecan & Elect FIME, Lab Res & Innovat Energy Technol LIITE, Av Univ S-N,Ciudad Univ, San Nicolas De Los Garza 66455, Nuevo Leon, Mexico
关键词
R1234ze(E)-R134a blends; Drop-in refrigerants; Vertical display refrigerator; Refrigerant charge; ENERGY PERFORMANCE EVALUATION; DROP-IN; R1234YF; REPLACEMENTS; R450A; ALTERNATIVES; R-134A;
D O I
10.1016/j.ijrefrig.2022.03.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
In recent years, the refrigerant drop-in replacement of R134a has been mainly motivated due to environmental issues. This study aims to experimentally compare the operating characteristics in light commercial refrigeration using a display refrigerator when R134a is substituted with pure R1234ze(E) and R1234ze(E)-R134a blends. The refrigerants R450A (R1234ze(E)-R134a 58-42wt% blend), and R1234ze(E)-R134a 90-10wt% blend with GWP of 547 and 150 respectively are evaluated. The adequate refrigerant charge is determined, and the performance evaluation is carried on under controlled ambient temperatures of 24, 32, and 40 degrees C. The results show a slightly reduced refrigerant charge for higher operating temperatures. Pure R1234ze(E) and its mixtures with R134a are a suitable short-term solution in light commercial refrigeration, satisfying ambient regulations with the maximum electric energy input increase by 6% under ambient temperature of 40 degrees C. Its reduced operating pressure of 36% at the condenser might result of interest for some applications.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [21] Experimental study on film condensation heat transfer characteristics of R134a, R1234ze(E) and R1233zd(E) over condensation tube with enhanced surfaces
    Ko, Ji-Woon
    Jeon, Dong-Soon
    HEAT AND MASS TRANSFER, 2020, 56 (11) : 3001 - 3010
  • [22] Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a
    Li, Shizhen
    Liu, Yingxin
    Liu, Yanjun
    Zhang, Jingzhi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (40) : 57166 - 57182
  • [23] A regressive model for dynamic impulsive instabilities during the condensation of R134a, R1234ze(E) and R1234yf refrigerants
    Kuczyński, Waldemar
    Charun, Henryk
    Piątkowski, Piotr
    Balasz, Blażej
    Chliszcz, Katarzyna
    Kuczyński, Waldemar (waldemar.kuczynski@tu.koszalin.pl), 1600, Elsevier Ltd (169):
  • [24] Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a
    Shizhen Li
    Yingxin Liu
    Yanjun Liu
    Jingzhi Zhang
    Environmental Science and Pollution Research, 2021, 28 : 57166 - 57182
  • [25] Experimental study on heat transfer condensation of R1234ze(E) and R134a inside a 4.0 mm OD horizontal microfin tube
    Diani, Andrea
    Campanale, Manuela
    Rossetto, Luisa
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 126 : 1316 - 1325
  • [26] A regressive model for dynamic impulsive instabilities during the condensation of R134a, R1234ze(E) and R1234yf refrigerants
    Kuczynski, Waldemar
    Charun, Henryk
    Piatkowski, Piotr
    Balasz, Blazej
    Chliszcz, Katarzyna
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 169
  • [27] Energy and exergy investigation of R1234ze as R134a replacement in vapor compression chillers
    Ben Jemaa, Radhouane
    Mansouri, Rami
    Boukholda, Ismail
    Bellagi, Ahmed
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (17) : 12877 - 12887
  • [28] Experimental analysis of the use of R1234yf and R1234ze(E) as drop-in alternatives of R134a in a water-to-water heat pump
    Maria Colombo, Luigi Pietro
    Lucchini, Andrea
    Molinaroli, Luca
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 115 : 18 - 27
  • [29] Experimental study on condensation heat transfer in vertical minichannels for new refrigerant R1234ze(E) versus R134a and R236fa
    Park, J. E.
    Vakili-Farahani, F.
    Consolini, L.
    Thome, J. R.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (03) : 442 - 454
  • [30] Experimental Investigation on Adiabatic Two-Phase Frictional Pressure Drop of R1234ze(E) and R134a in a Horizontal Minichannel
    Xu, Yu
    Yan, Zihao
    Li, Ling
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2022, 14 (02)