Clinical factors affecting the accuracy of a CT-based active infrared navigation system

被引:6
|
作者
Liu, Yajun [1 ]
Zhao, Jingwei [1 ]
Fan, Mingxing [1 ]
Lv, Yanwei [2 ]
Liu, Wenyong [3 ]
Tian, Wei
机构
[1] Beijing Jishuitan Hosp, Dept Spine Surg, Beijing, Peoples R China
[2] Beijing Jishuitan Hosp, Dept Epidemiol, Beijing, Peoples R China
[3] Beihang Univ, Sch Biol Sci & Med Engn, Beijing, Peoples R China
关键词
computer-assisted orthopaedic surgery (CAOS); spine; navigation; clinical accuracy; PEDICLE SCREW PLACEMENT; FLUOROSCOPY; INSERTION;
D O I
10.1002/rcs.1693
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Computer-assisted navigation technology has been widely used during spine surgery; however, the desired accuracy cannot be easily obtained and sustained. Our goal was to determine whether and how clinical factors affect the accuracy of a CT-based active infrared navigation system. Methods Using the Sawbone model, we recorded the clinical accuracy of the navigation system, based on several clinical statuses. Results Clinical accuracy may change when the height or angle of the bed is changed. Within the visible area of the camera, the nearer the distance between the camera and the model, the better the clinical accuracy. The clinical accuracy of the CT-based active infrared navigation system may decrease due to exposure to shadowless lamps. Conclusions The clinical accuracy of the CT-based active infrared navigation system may be influenced by the clinical status of shadowless lamps, different distances between the camera and model and different postures of the surgical bed. Copyright (C) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:568 / 571
页数:4
相关论文
共 50 条
  • [41] Comparative examination of the accuracy of a mechanical and an optical system in CT and MRT based instrument navigation
    Hassfeld, S
    Mühling, J
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 29 (06) : 400 - 407
  • [42] Analysis of two elements affecting positioning accuracy of celestial navigation system
    Zhu, Chang-Zheng
    Ju, Yong-Zhong
    [J]. Yuhang Xuebao/Journal of Astronautics, 2010, 31 (10): : 2309 - 2313
  • [43] Dosimetric accuracy of the cone-beam CT-based treatment planning of the Vero system: a phantom study
    Yohannes, Indra
    Prasetio, Heru
    Kallis, Karoline
    Bert, Christoph
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 106 - 113
  • [44] Clinical validation of a CT-based impulse oscillometry model
    Bordas, Rafel
    Gonem, Sherif
    Lefevre, Christophe
    Veeckmans, Bart
    Hartley, Ruth
    Pitt-Francis, Joe
    Fetita, Catalin
    Brightling, Chris
    Owers-Bradley, John
    Kay, David
    Siddiqui, Salman
    Burrowes, Kelly
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [45] Robotic total knee arthroplasty - The accuracy of CT-based component placement
    Decking, J
    Theis, C
    Achenbach, T
    Roth, E
    Nafe, B
    Eckardt, A
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (05): : 573 - 579
  • [46] The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
    Saleki, Leila
    Ghafarian, Pardis
    Bitarafan-Rajabi, Ahmad
    Yaghoobi, Nahid
    Fallahi, Babak
    Ay, Mohammad Reza
    [J]. IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 27 (02): : 63 - 72
  • [47] Comparison of Alignment Accuracy and Clinical Outcomes between a CT-Based, Saw Cutting Robotic System and a CT-Free, Jig-guided Robotic System for Total Knee Arthroplasty
    Zhou, Ge
    Wang, Xinguang
    Geng, Xiao
    Li, Zijian
    Tian, Hua
    [J]. ORTHOPAEDIC SURGERY, 2024, 16 (05) : 1168 - 1174
  • [48] Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty
    Hoenecke, Heinz R., Jr.
    Hermida, Juan C.
    Flores-Hernandez, Cesar
    D'Lima, Darryl D.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (02) : 166 - 171
  • [49] 3D SPECT/CT-based navigation to the sentinel node in the groin
    Van den Berg, N. S.
    KleinJan, G. H.
    Brouwer, O. R.
    Matheron, H. M.
    Horenblas, S.
    Van der Poel, H. G.
    Olmos, R. A. Valdes
    Van Leeuwen, F. W. B.
    [J]. EUROPEAN JOURNAL OF CANCER, 2013, 49 : S250 - S250
  • [50] Clinical accuracy of the VISLAN surgical navigation and guidance system
    Evans, RJ
    Strong, AJ
    Colchester, ACF
    Zhao, J
    HoltonTainter, K
    [J]. CAR '96: COMPUTER ASSISTED RADIOLOGY, 1996, 1124 : 799 - 804